Exploring DTI-derived metrics to non-invasively track recellularisation in vascular tissue engineering

Despite significant growth in the field of tissue engineering over the past decades, non-invasive, non-destructive methods to characterise recellularisation of grafts are lacking. Here, we investigate a non-invasive magnetic resonance imaging technique, diffusion tensor imaging (DTI), within acellular and recellularised vascular grafts. Using two decellularised porcine carotid grafts, smooth muscle cells were cultured dynamically for two weeks with terminal time points at day 3, 7, and 14. Grafts were fixed at each time point and investigated by DTI in an ex vivo set up. Semi-quantitative histology was carried out to investigate collagen, elastin, and cell density changes over time. DTI-derived metrics, namely the fractional anisotropy, mean diffusivity and tractography, not only were significantly different between day 3 and day 7 grafts, but also distinguished between acellular and recellularised grafts. Specifically, within the wet decellularised grafts, increasing fractional anisotropy was strongly correlated to increasing cell density. The results from this study show, for the first time, DTIs place in the field of tissue engineering, offering non-invasive, non-destructive insight into graft recellularisation.

bioengineering↗

A short-term decellularisation technique for porcine carotid arteries that conveys a structural stimulus to cells

In many cases, treatment for stenotic atherosclerotic lesions requires the use of bypass grafts to divert blood flow around the diseased vessel sections. Autologous vessels are considered the "gold standard" for bypass conduits; however, the shortage of healthy autologous vessels has resulted in an increasing focus on optimising synthetic, biological and/or tissue engineered vascular bypass grafts. While many of the previously published methods have been shown to fall short of producing an ideal TEVG, this report presents a decellularisation process that produces an acellular vascular graft that is efficient, cost effective, and could be readily automated. The resulting graft can be used "off the shelf", has preserved arterial structure and mechanical properties, and conforms to decellularisation criteria regarding the sufficient removal of cellular and genetic components. Additionally, the graft does not require any priming, supports molecular transport, can withstand supraphysiological pressures, and can support cell attachment and growth under physiological strain conditions whilst providing structural cues for cell adhesion and growth. Impact statementVascular disease remains the leading cause of mortality worldwide. In the absence of suitable autologous vessels, there currently exists a clear clinical need for off the shelf vascular grafts that can successfully bypass diseased arteries. This paper outlines a short-term method for obtaining such a graft. The technique used involves decellularising porcine carotid arteries whilst preserving arterial structure and mechanical properties and is compliant with the international standard for implantable vascular prostheses: EN ISO 7198:2017. Additionally, this protocol is cost and time effective, and produces reproducible "ready to use" acellular grafts that support molecular transport, can withstand supraphysiological pressures, and can support cell attachment and growth with controlled structural cues under physiological strain conditions.

bioengineering↗

Native Extracellular Matrix Orientation Determines Multipotent Vascular Stem Cell Proliferation in Response to Cyclic Uniaxial Tensile Strain and Simulated Stent Indentation

Cardiovascular disease is the leading cause of death worldwide, with multipotent vascular stem cells (MVSC) implicated in contributing to diseased vessels. MVSC are mechanosensitive cells which align perpendicular to cyclic uniaxial tensile strain. Within the blood vessel wall, collagen fibers constrain cells so that they are forced to align circumferentially, in the primary direction of tensile strain. In these experiments, MVSC were seeded onto the medial layer of decellularized porcine carotid arteries, then exposed to 10%, 1 Hz cyclic tensile strain for 10 days with the collagen fiber direction either parallel or perpendicular to the direction of strain. Cells aligned with the direction of the collagen fibers regardless of the orientation to strain. Cells aligned with the direction of strain showed an increased number of proliferative Ki67 positive cells, while those strained perpendicular to the direction of cell alignment showed no change in cell proliferation. A bioreactor system was designed to simulate the indentation of a single, wire stent strut. After 10 days of cyclic loading to 10% strain, MVSC showed regions of densely packed, highly proliferative cells. Therefore, MVSC may play a significant role in in-stent restenosis, and this proliferative response could potentially be controlled by controlling MVSC orientation relative to applied strain.