Search bioRxiv⌕ Search

Biology subjects

Martynowycz, M.

Publications and source records attributed to Martynowycz, M..

8 recordsLinked to original sources

Electron-counting in MicroED

The combination of high sensitivity and rapid readout makes it possible for electron-counting detectors to record cryogenic electron microscopy data faster and more accurately without increasing the exposure. This is especially useful for MicroED of macromolecular crystals where the strength of the diffracted signal at high resolution is comparable to the surrounding background. The ability to decrease the exposure also alleviates concerns about radiation damage which limits the information that can be recovered from a diffraction measurement. However, the dynamic range of electron-counting detectors requires careful data collection to avoid errors from coincidence loss. Nevertheless, these detectors are increasingly deployed in cryo-EM facilities, and several have been successfully used for MicroED. Provided coincidence loss can be minimized, electron-counting detectors bring high potential rewards.

biochemistry↗

Design and implementation of suspended drop crystallization

We have developed a novel crystal growth method known as suspended drop crystallization. Unlike traditional methods, this technique involves mixing protein and precipitant directly on an electron microscopy grid without any additional support layers. The grid is then suspended within a crystallization chamber which we designed, allowing for vapor diffusion to occur from both sides of the drop. A UV transparent window above and below the grid enables the monitoring of crystal growth via light, UV, or fluorescence microscopy. Once crystals have formed, the grid can be removed and utilized for x-ray crystallography or microcrystal electron diffraction (MicroED) directly without having to manipulate the crystals. To demonstrate the efficacy of this method, we grew crystals of the enzyme proteinase K and determined its structure by MicroED following FIB/SEM milling to render the sample thin enough for cryoEM. Suspended drop crystallization overcomes many of the challenges associated with sample preparation, providing an alternative workflow for crystals embedded in viscous media, sensitive to mechanical stress, and/or suffering from preferred orientation on EM grids.

biochemistry↗

Subphase Material Stabilizes Films of Pulmonary Surfactant

When compressed by the shrinking alveolar surface area during exhalation, films of pulmonary surfactant in situ reduce surface tension to levels, at which surfactant monolayers collapse from the surface in vitro. Vesicles of pulmonary surfactant added below these monolayers slow collapse. X-ray scattering here determined the structural changes that improve stability. Grazing incidence X-ray diffraction on monolayers of extracted calf surfactant detected an ordered phase. Mixtures of dipalmitoyl phosphatidylcholine and cholesterol, but not the phospholipid alone, mimic that structure. At concentrations that stabilize the monolayers, vesicles in the subphase had no effect on the unit cell, and the film remained monomolecular. The added vesicles, however, produced a concentration-dependent increase in the diffracted intensity. These results suggest that the enhanced resistance to collapse results from components of an ordered interfacial phase which partition from subphase to the surface, increasing the area of the ordered structure. SIGNIFICANCELow alveolar surface tensions are essential for maintaining the integrity of the pulmonary air-sacks during normal breathing. Films of pulmonary surfactant cause the low tensions. The interfacial structures required for the low surface tensions remain uncertain. These studies used X-ray scattering to determine the initial structure of pulmonary surfactant monolayers, and to establish how vesicles of pulmonary surfactant enhance the ability of those initial monolayers to sustain low tensions. The initial monolayers contained ordered structures that differ from the crystalline forms widely speculated to occur in alveolar films. The added vesicles had no effect on the local structure of the initial monolayer, but substantially increased the area of the ordered regions. This structural change reasonably explains the functional improvement.

biophysics↗

Qualitative analyses of polishing and pre-coating FIB milled crystals for MicroED

Microcrystal electron diffraction (MicroED) leverages the strong interaction between matter and electrons to determine protein structures from vanishingly small crystals. This strong interaction limits the thickness of crystals that can be investigated by MicroED, mainly due to absorption. Recent studies have demonstrated that focused ion beam (FIB) can thin even very large crystals into ideal sized lamellae however it is not clear how to best apply FIB-milling for MicroED. Here, The effects of polishing the lamellae, whereby the last few nanometers are milled away using a low-current gallium beam, are explored in both platinum pre-coated and uncoated samples. Our results suggest that pre-coating samples with a thin layer of platinum followed by polishing the crystal surfaces prior to data collection consistently led to superior results as indicated by higher signal/noise ratio, higher resolution and better refinement statistics. This study lays the foundation for routine and reproducible methodology for sample preparation in MicroED.

biochemistry↗

Collection of continuous rotation MicroED Data from Ion Beam Milled Crystals of Any Size

Microcrystal electron diffraction (MicroED) allows for macromolecular structure solution from nanocrystals. To create crystals of suitable size for MicroED data collection, sample preparation typically involves sonication or pipetting a slurry of crystals from a crystallization drop. The resultant crystal fragments are fragile and the quality of the data that can be obtained from them is sensitive to subsequent sample preparation for cryoEM as interactions in the water-air interface can damage crystals during blotting. Here, we demonstrate the use of a focused ion beam to generate lamellae of macromolecular protein crystals for continuous rotation MicroED that are of ideal thickness, easy to locate, and require no blotting optimization. In this manner, crystals of nearly any size may be scooped and milled to ideal dimensions prior to data collection, thus streamlining the methodology for sample preparation for MicroED.

biochemistry↗

Analysis of global and site-specific radiation damage in cryo-EM

Micro-crystal electron diffraction (MicroED) is an emerging method in cryo-EM for structure determination using nanocrystals. It has been used to solve structures of a diverse set of biomolecules and materials, in some cases to sub-atomic resolution. However, little is known about the damaging effects of the electron beam on samples during such measurements. We assess global and site-specific damage from electron radiation on nanocrystals of proteinase K and of a prion hepta-peptide and find that the dynamics of electron-induced damage follow well-established trends observed in X-ray crystallography. Metal ions are perturbed, disulfide bonds are broken, and acidic side chains are decarboxylated while the diffracted intensities decay exponentially with increasing exposure. A better understanding of radiation damage in MicroED improves our assessment and processing of all types of cryo-EM data.

biochemistry↗

A method to minimize condenser lens-induced hysteresis effects in a JEOL JEM-3200FSC microscope to enable stable cryoEM low-dose operations

Low dose imaging procedures are key for a successful cryoEM experiment (whether by electron cryotomography, single particle analysis, electron crystallography, or MicroED). We present a method to minimize magnetic hysteresis of the condenser lens system in the JEOL JEM-3200FSC transmission electron microscope (TEM) in order to maintain a stable optical axis for the beam path of low-dose imaging. The simple procedure involves independent voltage ramping of the CL1 and CL2 lenses immediately before switching to the focusing and exposure beam settings for data collection.\n\nHighlights O_LIEnables consistent horizontal beam position during low-dose mode switching\nC_LIO_LIFacilitates EM automated data collection for the JEOL JEM-3200FSC\nC_LIO_LIImproves beam stability in both TEM imaging and diffraction modes\nC_LI

biophysics↗

MicroED Structures from Micrometer Thick Protein Crystals

Theoretical calculations suggest that crystals exceeding 100 nm thickness are excluded by dynamical scattering from successful structure determination using microcrystal electron diffraction (MicroED). These calculations are at odds with experimental results where MicroED structures have been determined from significantly thicker crystals. Here we systematically evaluate the influence of thickness on the accuracy of MicroED intensities and the ability to determine structures from protein crystals one micrometer thick. To do so, we compare ab initio structures of a human prion protein segment determined from thin crystals to those determined from crystals up to one micrometer thick. We also compare molecular replacement solutions from crystals of varying thickness for a larger globular protein, proteinase K. Our results indicate that structures can be reliably determined from crystals at least an order of magnitude thicker than previously suggested by simulation, opening the possibility for an even broader range of MicroED experiments.\n\nSummaryAtomic resolution protein structures can be determined by MicroED from crystals that surpass the theoretical maximum thickness limit by an order of magnitude.

biochemistry↗