Search bioRxivSearch

Biology subjects

Martin, M. L.

Publications and source records attributed to Martin, M. L..

2 recordsLinked to original sources

Intensity Warping for multisite MRI Harmonization

In multisite neuroimaging studies there is often unwanted technical variation across scanners and sites. These \"scanner effects\" can hinder detection of biological features of interest, produce inconsistent results, and lead to spurious associations. We assess scanner effects in two brain magnetic resonance imaging (MRI) studies where subjects were measured on multiple scanners within a short time frame, so that one could assume any differences between images were due to technical rather than biological effects. We propose mica (multisite image harmonization by CDF alignment), a tool to harmonize images taken on different scanners by identifying and removing within-subject scanner effects. Our goals in the present study were to (1) establish a method that removes scanner effects by leveraging multiple scans collected on the same subject, and, building on this, (2) develop a technique to quantify scanner effects in large multisite trials so these can be reduced as a preprocessing step. We found that unharmonized images were highly variable across site and scanner type, and our method effectively removed this variability by warping intensity distributions. We further studied the ability to predict intensity harmonization results for a scan taken on an existing subject at a new site using cross-validation.

neuroscience

TAPAS: A Thresholding Approach for Probability Map Automatic Segmentation in Multiple Sclerosis

Total brain white matter lesion (WML) volume is the most widely established magnetic resonance imaging (MRI) outcome measure in studies of multiple sclerosis (MS). To estimate WML volume, there are a number of automatic segmentation methods, yet, manual delineation remains the gold standard approach. These approaches often yield a probability map to which a threshold is applied to create lesion segmentation masks. Unfortunately, few approaches systematically determine the threshold employed; many methods use a manually selected threshold, thus introducing human error and bias into the automated procedure. In this study, we propose and validate an automatic thresholding algorithm, Thresholding Approach for Probability Map Automatic Segmentation in Multiple Sclerosis (TAPAS), to obtain subject-specific threshold estimates for probability map automatic segmentation of T2-weighted (T2) hyperintense WMLs. Using multimodal MRI, the proposed method applies an automatic segmentation algorithm to obtain probability maps. We obtain the true subject-specific threshold that maximizes Sorensen-Dice Similarity Coefficient (DSC). Then the subject-specific thresholds are modeled on a naive estimate of volume using a general additive model. Applying this model, we predict a subject-specific threshold in data not used for training. We ran a Monte Carlo-resampled split-sample cross-validation (100 validation sets) using two data sets: the first obtained from the Johns Hopkins Hospital (JHH) on a Philips 3 Tesla (3T) scanner (n = 94) and a second collected at the Brigham and Womens Hospital (BWH) using a Siemens 3T scanner (n = 40). By means of the proposed automated technique, in the JHH data, we found an average reduction in subject-level absolute error of 0.1 mL per one mL increase in manual volume. Using Bland-Altman analysis, we found that volumetric bias associated with group-level thresholding is mitigated when applying TAPAS. The BWH data showed similar absolute error estimates using group-level thresholding or TAPAS likely since Bland-Altman analyses indicate no systematic biases associated with group or TAPAS volume estimates. The current study presents the first validated fully automated method for subject-specific threshold prediction to segment brain lesions.

neuroscience