Search bioRxiv⌕ Search

Biology subjects

Martens, K. J. A.

Publications and source records attributed to Martens, K. J. A..

5 recordsLinked to original sources

EVE is an open modular data analysis software for event-based localization microscopy

Event-based sensors (EBS), or neuromorphic vision sensors, offer a novel approach to imaging by recording light intensity changes asynchronously, unlike conventional cameras that capture light over fixed exposure times. This capability results in high temporal resolution, reduced data redundancy, and a wide dynamic range. This makes EBS ideal for Single-Molecule Localization Microscopy (SMLM) as SMLM relies on the sequential imaging of sparse, blinking fluorescent emitters to achieve super-resolution. Recent studies have shown that EBS can effectively capture these emitters, achieving spatial resolution comparable to traditional cameras. However, existing analyses of event-based SMLM (eveSMLM) data have relied on converting event lists into image frames for conventional analysis, limiting the full potential of the technology. To overcome this limitation, we developed EVE, a specialized software for analyzing eveSMLM data. EVE offers an integrated platform for detection, localization, and post-processing, with various algorithmic options tailored for the unique structure of eveSMLM data. EVE is user-friendly and features an open, modular infrastructure that supports ongoing development and optimization. EVE is the first dedicated tool for event-based SMLM, transforming the analysis process to fully utilize the spatiotemporal data generated by EBS. This allows researchers to explore the full potential of eveSMLM and encourages the development of new analytical methods and experimental improvements.

biophysics↗

Temporal analysis of relative distances (TARDIS) is a robust, parameter-free alternative to single-particletracking

In single-particle tracking (spt), individual particles are localized and tracked over time to probe their diffusion and molecular interactions. Temporal crossing of trajectories, blinking particles, and false-positive localizations present computational challenges that have remained difficult to overcome. Here, we introduce a robust, parameter-free alternative to spt: TARDIS. In TARDIS, an all-to-all distance analysis between localizations is performed with increasing temporal shifts. These pairwise distances fall in two categories: inter-particle distances not originating from the same particle, and intra-particle distances originating from the same particle. Since the distribution of inter-particle distances is unaffected by temporal shifts, the distribution of particle jump distances can be analytically fitted by analysing multiple temporal shifts. TARDIS outperforms existing tracking algorithms especially in complex conditions, and is even robust in scenarios that exceed the capabilities of current localization algorithms. Using TARDIS, we further show that measurements can be five-fold shorter without loss of information.

biophysics↗

Enabling spectrally resolved single-molecule localization microscopy at high emitter densities

Single-molecule localization microscopy (SMLM) is a powerful technique for elucidating structure and dynamics in the life- and material sciences with sub-50 nm spatial resolution. The simultaneous acquisition of spectral information (spectrally resolved SMLM, sSMLM) enables multiplexing using spectrally distinct fluorophores or enable the probing of local chemical environments by using solvachromatic fluorophores such as Nile Red. Until now, the widespread utilisation of sSMLM was hampered by several challenges: an increased complexity of the optical detection pathway, limited software solutions for data analysis, lower accessible emitter densities or smaller field-of-views, and overall compromised spatio-spectral resolution. Here, we present a low-cost implementation of sSMLM that addresses these challenges. Using a blazed, low-dispersion transmission grating positioned close to the image plane here represented by the camera sensor, the +1st diffraction order is minimally elongated compared to the point spread function of the 0th order and can therefore be analysed using common subpixel single-molecule localization algorithms. The distance between both PSFs provides accurate information on the spectral properties of the emitter. The minimal excess width of 1st order PSFs enables a fivefold higher emitter density compared to other sSMLM approaches whilst achieving a spatio-spectral localization accuracy sufficient to discriminate between fluorophores whose peak emission are less than 15 nm apart as demonstrated using dSTORM, DNA-PAINT and smFRET. We provide an ImageJ/Fiji plugin (sSMLMAnalyzer) and suitable Matlab scripts for data analysis. We envision that our approach will find widespread use in super-resolution applications that rely on distinguishing spectrally different fluorophores under low photon conditions.

biophysics↗

Analyzing engineered point spread functions using phasor-based single-molecule localization microscopy

The point spread function (PSF) of single molecule emitters can be engineered in the Fourier plane to encode three-dimensional localization information, creating double-helix, saddle-point or tetra-pod PSFs. Here, we describe and assess adaptations of the phasor-based single-molecule localization microscopy (pSMLM) algorithm to localize single molecules using these PSFs with sub-pixel accuracy. For double-helix, pSMLM identifies the two individual lobes and uses their relative rotation for obtaining z-resolved localizations, while for saddle-point or tetra-pod, a novel phasor-based deconvolution approach is used. The pSMLM software package delivers similar precision and recall rates to the best-in-class software package (SMAP) at signal-to-noise ratios typical for organic fluorophores. pSMLM substantially improves the localization rate by a factor of 2 - 4x on a standard CPU, with 1-1.5{middle dot}104 (double-helix) or 2.5{middle dot}105 (saddle-point/tetra-pod) localizations/second.

biophysics↗

An open microscopy framework suited for tracking dCas9 in live bacteria

Super-resolution microscopy is frequently employed in the life sciences, but the number of freely accessible and affordable microscopy frameworks, especially for single particle tracking photo-activation localization microscopy (sptPALM), remains limited. To this end, we designed the miCube: a versatile super-resolution capable fluorescence microscope, which combines high spatiotemporal resolution, good adaptability, low price, and easy installation. By providing all details, we hope to enable interested researchers to build an identical or derivative instrument. The capabilities of the miCube are assessed with a novel sptPALM assay relying on the heterogeneous expression of target genes. Here, we elucidate mechanistic details of catalytically inactive Cas9 (dead Cas9) in live Lactococcus lactis. We show that, lacking specific DNA target sites, the binding and unbinding of dCas9 to DNA can be described using simplified rate constants of kbound[->]free = 30-80 s-1 and kfree[->]bound = 15-40 s-1. Moreover, after providing specific DNA target sites via DNA plasmids, the plasmid-bound dCas9 population size decreases with increasing dCas9 copy number via a mono-exponential decay, indicative of simple disassociation kinetics.

biophysics↗