Wireless Measurements Using Electrical Impedance Spectroscopy to Monitor Fracture Healing

There is an unmet need for improved, clinically relevant methods to longitudinally quantify bone healing during fracture care. Here we develop a smart bone plate to wirelessly monitor healing utilizing electrical impedance spectroscopy (EIS) to provide real-time data on tissue com-position within the fracture callus. To validate our technology, we created a 1-mm rabbit tibial defect and fixed the bone with a standard veterinary plate modified with a custom-designed housing that included two impedance sensors capable of wireless transmission. Impedance magnitude and phase measurements were transmitted every 48-hours for up to 10-weeks. Bone healing was assessed by X-ray, CT, and histomorphometry. Our results indicated the sensors successfully incorporated into the fracture callus and did not impede repair. Electrical impedance, resistance, and reactance increased steadily from weeks 3 to 7--corresponding to the transition from hematoma to cartilage to bone within the fracture gap--then plateaued as the bone began to consolidate. These three electrical readings significantly correlated with traditional measurements of bone healing and successfully distinguished between union and not healed fractures, with the strongest relationship found with impedance magnitude. These results suggest that our EIS smart bone plate can provide continuous and highly sensitive quantitative tissue measurements throughout the course of fracture healing to better guide personalized clinical care.

bioengineering↗

Columnar localization and laminar origin of cortical surface electrical potentials

Electrocorticography (ECoG) methodologically bridges basic neuroscience and understanding of human brains in health and disease. However, the localization of ECoG signals across the surface of the brain and the spatial distribution of their generating neuronal sources are poorly understood. To address this gap, we recorded from rat auditory cortex using customized ECoG, and simulated cortical surface electrical potentials with a full-scale, biophysically detailed cortical column model. Experimentally, ECoG-derived auditory representations were tonotopically organized and signals were anisotropically localized to [≤]{+/-}200 m, i.e., a single cortical column. Biophysical simulations reproduce experimental findings, and indicate that neurons in cortical layers V and VI contribute [~]85% of evoked high-gamma signal recorded at the surface. Cell number and synchronicity were the primary biophysical properties determining laminar contributions to evoked ECoG signals, while distance was only a minimal factor. Thus, evoked ECoG signals primarily originate from neurons in the infragranular layers of a single cortical column. In BriefBaratham et al., investigated the localization and origins of sensory evoked ECoG responses. They experimentally found that ECoG responses were anisotropically localized [≤]{+/-}200 m, i.e., a single cortical column. Biophysically detailed simulations revealed that neurons in layers V &VI were the primary sources of evoked ECoG responses, in contrast to common thinking. HighlightsEvoked ECoG signals are localized on the surface to a cortical column. Neurons in cortical layers V and VI constitute the vast majority of the signal recorded at the surface. Different laminar contributions to ECoG signal are driven by cell density and synchronicity.

neuroscience↗

Monitoring deep-tissue oxygenation with a millimeter-scale ultrasonic implant

Deep tissue oxygenation monitoring has many potential applications. Vascular complications after solid organ transplantation, for example, frequently lead to graft ischemia, dysfunction or loss, and can occur months after transplantation. While imaging approaches can provide intermittent assessments of graft perfusion, they require highly skilled practitioners, and fail to directly assess graft oxygenation. Existing tissue oxygen monitoring systems have many drawbacks, including the need for wired connections, the inability to provide real-time data, and, crucially, an operation that is limited to surface tissues. Here, we present the first wireless, minimally-invasive deep tissue oxygen monitoring system that provides continuous real-time data from centimeter-scale depths in a clinically-relevant large animal (sheep) model and demonstrates operation at great depths (up to 10 cm) through ex vivo porcine tissue. The system relies on a millimeter-sized, wireless, battery-free, implantable luminescence oxygen sensor that is powered by ultrasound and capable of bi-directional data transfer with an external transceiver. We present various aspects of system and sensor performance and demonstrate the operation of the system in vitro in distilled water, phosphate-buffered saline (PBS) and undiluted human serum, ex vivo through porcine tissue, and in vivo in a sheep model. We believe this technology represents a new class of diagnostic system particularly suitable for organ monitoring, as well as other surgical or critical care indications.

bioengineering↗

Ceramic Packaging in Neural Implants

The lifetime of neural implants is strongly dependent on packaging due to the aqueous and biochemically aggressive nature of the body. Over the last decade, there has been a drive towards neuromodulatory implants which are wireless and approaching millimeter-scales with increasing electrode count. A so-far unrealized goal for these new types of devices is an in-vivo lifetime comparable to a sizable fraction of a healthy patient’s lifetime (>10-20 years). Existing, approved medical implants commonly encapsulate components in metal enclosures (e.g. titanium) with brazed ceramic inserts for electrode feedthrough. It is unclear how amenable the traditional approach is to the simultaneous goals of miniaturization, increased channel count, and wireless communication. Ceramic materials have also played a significant role in traditional medical implants due to their dielectric properties, corrosion resistance, biocompatibility, and high strength, but are not as commonly used for housing materials due to their brittleness and the difficulty they present in creating complex housing geometries. However, thin film technology has opened new opportunities for ceramics processing. Thin films derived largely from the semiconductor industry can be deposited and patterned in new ways, have conductivities which can be altered during manufacturing to provide conductors as well as insulators, and can be used to fabricate flexible substrates. In this review, we give an overview of packaging for neural implants, with an emphasis on how ceramic materials have been utilized in medical device packaging, as well as how ceramic thin film micromachining and processing may be further developed to create truly reliable, miniaturized, neural implantsCompeting Interest StatementThe authors have declared no competing interest.View Full Text

bioengineering↗

Design of Ceramic Packages for Acoustically Coupled Implantable Medical Devices

ObjectiveUltrasonic acoustic power transfer is an efficient mechanism for coupling energy to millimeter and sub-millimeter implants in the body. To date, published ultrasonically powered implants have been encapsulated with thin film polymers that are susceptible to well-documented failure modes in vivo, including water penetration and attack by the body. As with all medical implants, packaging with ceramic or metallic materials can reduce water vapor transmission and improve biostability to provide decadal device lifetime. In this paper, we evaluate methods of coupling acoustic energy to the interior of ceramic packages. MethodsThe classic wave approach and modal expansion are used to obtain analytical expressions for acoustic transmission through two different package designs and these approaches are validated experimentally. A candidate package design is demonstrated using alumina packages and titanium lids, designed to be acoustically transparent. ResultsBulk modes are shown to be more effective at coupling acoustic energy to a piezoelectric receiver than flexural modes. Using bulk modes, packaged motes have an overall link efficiency of roughly 10%, compared to 25% for unpackaged motes. Packaging does not have a significant effect on translational misalignment penalties, but does increase angular misalignment penalties. Passive amplitude-modulated backscatter communication is demonstrated. ConclusionThin lids enable the use of acoustically coupled devices even with package materials of very different acoustic impedance. Significance: This work provides an analysis and method for designing packages that enable acoustic coupling with implantable medical devices, which could facilitate clinical translation.

bioengineering↗

The \"sewing machine\" for minimally invasive neural recording

We present a system for scalable and customizable recording and stimulation of neural activity. In large animals and humans, the current benchmark for high spatial and temporal resolution neural interfaces are fixed arrays of wire or silicon electrodes inserted into the parenchyma of the brain. However, probes that are large and stiff enough to penetrate the brain have been shown to cause acute and chronic damage and inflammation, which limits their longevity, stability, and yield. One approach to this problem is to separate the requirements of the insertion device, which should to be as stiff as possible, with the implanted device, which should be as small and flexible as possible. Here, we demonstrate the feasibility and scalability of this approach with a system incorporating fine and flexible thin-film polymer probes, a fine and stiff insertion needle, and a robotic insertion machine. Together the system permits rapid and precise implantation of probes, each individually targeted to avoid observable vasculature and to attain diverse anatomical targets. As an initial demonstration of this system, we implanted arrays of electrodes in rat somatosensory cortex, recorded extracellular action potentials from them, and obtained histological images of the tissue response. This approach points the way toward a new generation of scaleable, stable, and safe neural interfaces, both for the basic scientific study of brain function and for clinical applications.

neuroscience↗

MEMS-Actuated Carbon Fiber Microelectrode for Neural Recording

Microwire and microelectrode arrays used for cortical neural recording typically consist of tens to hundreds of recording sites, but often only a fraction of these sites are in close enough proximity to firing neurons to record single-unit activity. Recent work has demonstrated precise, depth-controllable mechanisms for the insertion of single neural recording electrodes, but these methods are mostly only capable of inserting electrodes which elicit adverse biological response. We present an electrostatic-based actuator capable of inserting individual carbon fiber microelectrodes which elicit minimal to no adverse biological response. The device is shown to insert a carbon fiber recording electrode into an agar brain phantom and can record an artificial neural signal in saline. This technique provides a platform generalizable to many microwire-style recording electrodes.

bioengineering↗

An actuated neural probe architecture for reducing gliosis-induced recording degradation

Glial encapsulation of chronically implanted neural probes inhibits recording and stimulation, and this signal loss is a significant factor limiting the clinical viability of most neural implant topologies for decades-long implantation. We demonstrate a mechanical proof of concept for silicon shank-style neural probes intended to minimize gliosis near the recording sites. Compliant whiskers on the edges of the probe fold inward to minimize tissue damage during insertion. Once implanted to the target depth and retracted slightly, these whiskers splay outward. The splayed tips, on which recording sites could be patterned, extend beyond the typical 50-100 micron radius of a glial scar. The whiskers are micron-scale to minimize or avoid glial scarring. Electrically inactive devices with whiskers of varying widths and curvature were designed and monolithically fabricated from a five-micron silicon-on-insulator (SOI) wafer, and their mechanical functionality was demonstrated in a 0.6% agar brain phantom. Deflection was plotted versus deflection speed, and those that were most compliant actuated successfully. This probe requires no preparation for use beyond what is typical for a shank-style silicon probe.

bioengineering↗

Smart bone plates can monitor fracture healing

One Sentence SummaryElectrical impedance measurements using microscale sensors implanted in two mouse fracture models tracked longitudinal differences between individual mice with proper healing and mice experiencing poor healing, laying the groundwork for translation to the clinic through integration into fracture fixation implants (i.e. instrumented bone plates).\n\nAbstractThere are currently no standardized methods for monitoring fracture healing. While histological studies can clearly identify the tissues found in the four stages of repair, in practice surgeons rely on X-ray, which is only useful at later stages of healing after mineralization has occurred. As electrical impedance spectroscopy (EIS) has previously been used to distinguish tissue types during healing, we hypothesized that microscale sensors embedded in the fracture callus could track the changing tissue with high sensitivity. Using in vivo mouse fracture models, we present the first evidence that microscale instrumented implants provide a route for post-operative fracture monitoring. In this study, we implanted sensors in mouse long bone fractures fixed with either external fixators or bone plates. EIS measurements taken across two electrodes implanted in the fracture gap were able to track longitudinal differences between individual mice with proper healing and mice experiencing poor healing. We additionally present an equivalent circuit model that combines the EIS data in order to classify healing states of fractures. Lastly, we show that EIS measures are strongly correlated with standard {micro}CT measures of healing and that these correlations validate clinically-relevant operating frequencies for implementation of this technique. The data from these two models demonstrate that this technique can be translated to the clinic through integration into current fracture management strategies such as bone plating, providing physicians with quantitative information about the state of a fracture to guide clinical decision-making for patients.

bioengineering↗

A high-density carbon fiber neural recording array technology

Abstract.Objective: Microwire and Utah-style neural recording arrays are the predominant devices used for cortical neural recording, but the implanted electrodes cause a significant adverse biological response and suffer from well-studied performance degradation. Recent work has demonstrated that carbon fiber electrodes do not elicit this same adverse response, but these existing designs are not practically scalable to hundreds or thousands of recording sites. We present technology that overcomes these issues while additionally providing fine electrode pitch for spatial oversampling.\n\nApproach: We present a 32-channel carbon fiber monofilament-based intracortical neural recording array fabricated through a combination of bulk silicon microfabrication processing and microassembly. This device represents the first truly two-dimensional carbon fiber neural recording array. The density, channel count, and size scale of this array are enabled by an out-of-plane microassembly technique in which individual fibers are inserted through metallized and isotropically conductive adhesive-filled holes in an oxide-passivated microfabricated silicon substrate.\n\nMain results: Five-micron diameter fibers are spaced at a pitch of 38 microns, four times denser than state of the art one-dimensional arrays. The fine diameter of the carbon fibers affords both minimal cross-section and nearly three orders of magnitude greater lateral compliance than standard tungsten microwires. Typical 1 kHz impedances are on the order of hundreds of kiloohms, and successful in vivo recording is demonstrated in the motor cortex of a rat. 22 total units are recorded on 20 channels, with unit SNR ranging from 0.85 to 4.2.\n\nSignificance: This is the highest density microwire-style electrode array to date, and this fabrication technique is scalable to a larger number of electrodes and allows for the potential future integration of microelectronics. Large-scale carbon fiber neural recording arrays are a promising technology for reducing the inflammatory response and increasing the information density, particularly in neural recording applications where microwire arrays are already used.

bioengineering↗