Search bioRxiv⌕ Search

Biology subjects

Lowerison, M.

Publications and source records attributed to Lowerison, M..

17 recordsLinked to original sources

Whole-body Super-resolution Functional and Molecular Imaging with Panoramic Photoacoustic-Ultrasound Tomography

Photoacoustic (PA) and ultrasound (US) imaging provide complementary molecular, functional, and anatomical contrasts. Here, we present a panoramic PA-US imaging platform that integrates multispectral PA computed tomography (PACT) along with reflection-mode and transmission-mode US imaging through a single shared full-ring ultrasound array. We employ an ultrafast planewave transmission scheme in reflection-mode US for power Doppler (PWD) imaging and ultrasound localization microscopy (ULM). Additionally, we use the transmission-mode US to reconstruct a spatially resolved speed of sound (SoS) map that corrects both PA and US reconstruction. Such correction sharpens the resolution of PACT, suppresses the artifacts of PWD, and improves microbubble localization of ULM. Elevational scanning further enables whole-body volumetric imaging with co-registered PA and US contrasts. The integrated system maps photoswitchable DrBphP1-expressing tumors alongside their blood perfusion and oxygenation environment. Applying the platform to monitor unilateral renal ischemia-reperfusion injury, we report that microvascular perfusion and renal oxygenation recover at different rates. Collectively, we demonstrate that the integrated PA-US imaging platform provides a unified framework for multiparametric study of anatomy, perfusion, microvascular flow, oxygenation, and molecular activities.

bioengineering↗

Three-Dimensional Photoacoustic Tomography with Ultrasound Localization Priors

Three-dimensional photoacoustic tomography (3D-PAT) enables noninvasive structural and functional imaging with optical absorption contrast and ultrasonic detection depth. However, its spatial resolution is limited by acoustic diffraction, and incomplete detection geometry can substantially degrade image fidelity and quantitative accuracy. Here, we present a ULM-guided model-based reconstruction framework, termed 3D-PAULMprior that incorporates sub-diffraction vascular priors from concurrent ultrasound localization microscopy (ULM) into 3D photoacoustic reconstruction. The method uses weighted regional Laplacian regularization to integrate high-resolution vascular information into the inverse problem, thereby enhancing vascular sharpness, suppressing limited-view artifacts, and improving blood oxygen saturation estimation. We validated 3D-PAULMprior using numerical simulations, tissue-mimicking phantoms, and in vivo mouse brain imaging. Compared with conventional reconstruction, 3D- PAULMprior improved spatial resolution by over 50%, increased contrast-to-noise ratio by 261.2%, and enhanced structural similarity index by 24.6%. In vivo, 3D-PAULMprior recovered vascular structures that were poorly resolved or missing in conventional reconstructions and produced more spatially confined sO2 maps. These results establish 3D-PAULMprior as a robust multimodal reconstruction strategy for high-resolution structural and functional photoacoustic imaging.

bioengineering↗

Microbubble Backscattering Intensity Improves the Sensitivity of Three-dimensional (3D) Functional Ultrasound Localization Microscopy (fULM)

Functional ultrasound localization microscopy (fULM) enables brain-wide mapping of neural activity at micron-scale resolution but suffers from limited sensitivity due to sparse and noisy microbubble (MB) detections. Extending fULM into three dimensions (3D) further exacerbates these challenges because of low-frequency matrix arrays, reduced localization efficiency, and severe data sparsity. To address these limitations, we developed a statistical framework that models MB arrivals in 3D as a Poisson process accounting for localization efficiency, detection probability, and backscattered amplitude. This analysis predicts that integrating amplitude with count-based fULM improves functional sensitivity, particularly under high MB concentrations where localization saturates. Three-dimensional MB advection simulations confirmed these predictions, showing that backscattering fULM (B-fULM) maintains sensitivity at higher MB concentrations where conventional fULM fails. In rat brain experiments, B-fULM yielded stronger and more robust stimulus-evoked responses, with SNR gains of 18% in the somatosensory cortex and 61% in the thalamus, while preserving super-resolved spatial detail (33.4 m for B-fULM vs 35.7 m for fULM). These results establish B-fULM as a practical and sensitive approach for super-resolved 3D functional neuroimaging

bioengineering↗

Advanced deep-tissue imaging and manipulation enabled by biliverdin reductase knockout.

We developed near-infrared (NIR) photoacoustic and fluorescence probes, as well as optogenetic tools from bacteriophytochromes, and enhanced their performance using biliverdin reductase-A knock-out model (Blvra-/-). Blvra-/- elevates endogenous heme-derived biliverdin chromophore for bacteriophytochrome-derived NIR constructs. Consequently, light-controlled transcription with IsPadC-based optogenetic tool improved up to 25-fold compared to wild-type cells, with 100-fold activation in Blvra-/- neurons. In vivo, light-induced insulin production in Blvra-/- reduced blood glucose in diabetes by [~]60%, indicating high potential for optogenetic therapy. Using 3D photoacoustic, ultrasound, and two-photon fluorescence imaging, we overcame depth limitations of recording NIR probes. We achieved simultaneous photoacoustic imaging of DrBphP in neurons and super-resolution ultrasound localization microscopy of blood vessels [~]7 mm deep in the brain, with intact scalp and skull. Two-photon microscopy provided cell-level resolution of miRFP720-expressing neurons [~]2.2 mm deep. Blvra-/- significantly enhances efficacy of biliverdin-dependent NIR systems, making it promising platform for interrogation and manipulation of biological processes.

cell biology↗

Combined Nanodrops Imaging and Ultrasound Localization Microscopy for Detecting Intracerebral Hemorrhage

ObjectiveAdvanced imaging methods are crucial for understanding stroke mechanisms and discovering effective treatments to reduce bleeding and enhance recovery. In preclinical in vivo stroke imaging, MRI, CT, and optical imaging are commonly used to evaluate stroke outcomes in rodent models. However, MRI and CT have limited spatial resolution for rodent brains, and optical imaging is hindered by limited imaging depth of penetration. Here we introduce a novel contrast-enhanced ultrasound imaging method to overcome these challenges and characterize intracerebral hemorrhage with unique insights. MethodsWe combined microbubble (MB)-based ultrasound localization microscopy (ULM) and nanodrop (ND)- based vessel leakage imaging to achieve simultaneous microvascular imaging and hemorrhage detection. ULM maps brain-wide cerebral vasculature with high spatial resolution and identifies microvascular impairments around hemorrhagic areas. NDs are sub-micron liquid-core particles which can extravasate due to blood-brain barrier (BBB) breakdown, serving as positive contrast agents to detect hemorrhage sites. ResultsOur findings demonstrate that NDs could effectively accumulate in the hemorrhagic site and reveal the location of the bleeding areas upon activation by focused ultrasound beams. ULM further reveals the microvascular damage manifested in the form of reduced vascularity and decreased blood flow velocity across areas affected by the hemorrhagic stroke. ConclusionThe results demonstrate that sequential ULM combined with ND imaging is a useful imaging tool for basic in vivo research in stroke with rodent models where brain-wide detection of active bleeding and microvascular impairment are essential.

bioengineering↗

Capillary-scale Microvessel Imaging with High-frequency Ultrasound Localization Microscopy in Mouse Brain

Ultrasound localization microscopy is a super-resolution vascular imaging technique which has garnered substantial interest as a tool for small animal neuroimaging, neuroscience research, and the characterization of vascular pathologies. In the pursuit of increasingly high-fidelity reconstructions of microvasculature, there remains several outstanding questions concerning this sub-diffraction imaging technology, including the accurate reconstruction of microvessels approaching the capillary scale and the pragmatic challenges associated with long data acquisition times. In the context of small animal neurovascular imaging, we posit that increasing the ultrasound imaging frequency is a straightforward approach to enable higher concentrations of microbubble contrast agents, thus increasing the likelihood of microvascular/capillary mapping and decreasing the imaging duration. We demonstrate that higher frequency imaging results in improved ULM fidelity and more efficient microbubble localization due to a smaller microbubble point-spread function that is easier to localize, and which can achieve a higher localizable concentration within the same unit volume of tissue. A select example of in vivo capillary-level vascular reconstruction is demonstrated for the highest frequency imaging probe, which has substantial implications for neuroscientists investigating microvascular function in disease states, regulation, and brain development. High frequency ULM yielding a spatial resolution of 7.1m, as measured by Fourier ring correlation, throughout the entire depth of the brain, highlighting this technology as a highly relevant tool for neuroimaging research.

neuroscience↗

Three-dimensional Shear Wave Elastography Using Acoustic Radiation Force and A 2-D Row-Column Addressing (RCA) Array

Acoustic radiation force (ARF)-based shear wave elastography (SWE) is a clinically available ultrasound imaging mode that noninvasively and quantitatively measures tissue stiffness. Current implementations of ARF-SWE are largely limited to 2-D imaging, which does not provide robust estimation of heterogeneous tissue mechanical properties. Existing 3-D ARF-SWE solutions that are clinically available are based on wobbler probes, which cannot provide true 3-D shear wave motion detection. Although 3-D ARF-SWE based on 2-D matrix arrays have been previously demonstrated, they do not provide a practical solution because of the need for a high channel-count ultrasound system (e.g., 1024-channel) to provide adequate volume rates and the delicate circuitries (e.g., multiplexers) that are vulnerable to the long-duration "push" pulses. To address these issues, here we propose a new 3-D ARF-SWE method based on the 2-D row-column addressing (RCA) array which has a much lower element count (e.g., 256), provides an ultrafast imaging volume rate (e.g., 2000 Hz), and can withstand the push pulses. In this study, we combined the comb-push shear elastography (CUSE) technique with 2-D RCA for enhanced SWE imaging field-of-view. In vitro phantom studies demonstrated that the proposed method had robust 3-D SWE performance in both homogenous and inclusion phantoms. An in vivo study on a breast cancer patient showed that the proposed method could reconstruct 3-D elasticity maps of the breast lesion, which was validated using a commercial ultrasound scanner. These results demonstrate strong potential for the proposed method to provide a viable and practical solution for clinical 3-D ARF-SWE.

bioengineering↗

Context-Aware Deep Learning Enables High-Efficacy Localization of High Concentration Microbubbles for Super-Resolution Ultrasound Localization Microscopy

Ultrasound localization microscopy (ULM) is an emerging super-resolution imaging technique for deep tissue microvascular imaging. However, conventional localization methods are constrained by low microbubble (MB) concentration, as accurate localization requires a strict separation of MB point spread functions (PSFs). Furthermore, deep learning-based localization techniques are often limited in their ability to generalize to in vivo ultrasound data due to challenges in accurately modeling highly variable MB PSF distributions and ultrasound imaging conditions. To address these limitations, we propose a novel deep learning-pipeline, LOcalization with Context Awareness (LOCA)-ULM, which employs simulation that incorporates MB context to generate synthetic data that closely resemble real MB signals, and a loss function that considers both MB count and localization loss. In in silico experiments, LOCA-ULM outperformed conventional localization with superior MB detection accuracy (94.0% vs. 74.9%) and a significantly lower MB missing rate (13.2% vs 74.8%). In vivo, LOCA-ULM achieved up to three-fold increase in MB localization efficiency and a x 9.5 faster vessel saturation rate than conventional ULM.

bioengineering↗

High Volume Rate 3-D Ultrasound Imaging Using Fast-Tilting and Redirecting Reflectors

3-D ultrasound imaging has many advantages over 2-D imaging such as more comprehensive tissue evaluation and less operator dependence. Although many 3-D ultrasound imaging techniques have been developed in the last several decades, a low-cost and accessible solution with high imaging volume rate and imaging quality remains elusive. Recently we proposed a new, high volume rate 3-D ultrasound imaging technique: Fast Acoustic Steering via Tilting Electromechanical Reflectors (FASTER), which uses a water-immersible and fast-tilting acoustic reflector to steer ultrafast plane waves in the elevational direction to achieve high volume rate 3-D ultrasound imaging with conventional 1-D array transducers. However, the initial implementation of FASTER imaging only involves a single fast-tilting acoustic reflector, which is inconvenient to use because the probe cannot be held in the regular upright position. Also, conventional FASTER imaging can only be performed inside a water tank because of the necessity of using water for acoustic conduction. To address these limitations of conventional FASTER, here we developed a novel ultrasound probe clip-on device that encloses a fast-tilting reflector, a redirecting reflector, and an acoustic wave conduction medium. The new FASTER 3-D imaging device can be easily attached to or removed from clinical ultrasound transducers, allowing rapid transformation from 2-D to 3-D ultrasound imaging. In vitro B-mode imaging studies demonstrated that the proposed method provided comparable imaging quality (e.g., spatial resolution and contrast-to-noise ratio) to conventional, mechanical-translation-based 3-D imaging while providing a much faster 3-D volume rate (e.g., 300 Hz vs [~]10 Hz). In addition to B-mode imaging, we also demonstrated 3-D power Doppler imaging and 3-D super-resolution ultrasound localization microscopy with the newly developed FASTER device. An in vivo imaging study showed that the FASTER device could clearly visualize the 3-D anatomy of the basilic vein of a healthy volunteer, and customized beamforming was implemented to accommodate the speed of sound difference between the acoustic medium and the imaging object (e.g., soft tissue). These results suggest that the newly developed redirecting reflector and the clip-on device could overcome key hurdles for future clinical translation of the FASTER 3-D imaging technology.

bioengineering↗

Super-resolution ultrasound imaging of cerebrovascular impairment in a mouse model of Alzheimer's disease

Increasing evidence has suggested a link between cerebrovascular disease and the cognitive impairment of patients with Alzheimers disease. However, cerebrovascular disease and Alzheimers disease share several risk factors making it unclear whether cerebrovascular deficiency and Alzheimers disease pathology have additive effects on cognition or if cerebrovascular impairment merely exacerbates existing Alzheimers disease-associated cognitive decline. Additionally, early-stage Alzheimers disease typically involves hippocampal atrophy, complicating most efforts to elucidate the interplay between cerebral microvascular function and Alzheimers disease progression due to the necessity of probing deep-brain structures. The purpose of this study was to demonstrate the use of ultrasound localization microscopy on the 5xFAD mouse model of Alzheimers disease (3-month and 6-month-old cohorts) in comparison to age-matched wild-type controls, revealing microvascular scale reconstructions throughout the whole brain depth, to visualize and quantify Alzheimers disease-associated vascular impairments. We found that functional decreases in hippocampal and entorhinal flow velocity preceded structural derangements in regional vascular density. In addition to providing global vascular quantifications of deep brain structures with a high local resolution, this technology also permitted hierarchical analysis of individual vessels and, in some cases, potentially allowed for decoupling of arteriole and venous flow contributions. Co-registered histological sectioning confirmed the regionalized hypo-perfusion deficits seen on ultrasound imaging, which were co-localized with amyloid beta plaque deposition. Significance statementThe study of the impact of cerebrovascular disease on Alzheimers disease pathology is complicated by the need to image deep-brain structures with high vascular fidelity. We demonstrate that ultrasound localization microscopy, a super-resolution acoustic imaging technique, is capable of imaging cerebrovasculature throughout the entire depth of the brain at a microvascular scale. This technology was applied to the 5xFAD mouse model of Alzheimers disease, where it was found that 5xFAD animals have significant impairments in vascular function in the entorhinal cortex and hippocampal region in comparison to age matched controls at the 3-month timepoint. Structural derangements in cerebrovasculature were only observed in the 6-month-old animal cohorts, with a maintained impairment in vascular function.

neuroscience↗

Contrast-free Super-resolution Doppler (CS Doppler) based on Deep Generative Neural Networks

Super-resolution ultrasound microvessel imaging based on ultrasound localization microscopy (ULM) is an emerging imaging modality that is capable of resolving micron-scaled vessels deep into tissue. In practice, ULM is limited by the need for contrast injection, long data acquisition, and computationally expensive post-processing times. In this study, we present a contrast-free super-resolution Doppler (CS Doppler) technique that uses deep generative networks to achieve super-resolution with short data acquisition. The training dataset is comprised of spatiotemporal ultrafast ultrasound signals acquired from in vivo mouse brains, while the testing dataset includes in vivo mouse brain, chicken embryo chorioallantoic membrane (CAM), and healthy human subjects. The in vivo mouse imaging studies demonstrate that CS Doppler could achieve an approximate 2-fold improvement in spatial resolution when compared with conventional power Doppler. In addition, the microvascular images generated by CS Doppler showed good agreement with the corresponding ULM images as indicated by a structural similarity index of 0.7837 and a peak signal-to-noise ratio of 25.52. Moreover, CS Doppler was able to preserve the temporal profile of the blood flow (e.g., pulsatility) that is similar to conventional power Doppler. Finally, the generalizability of CS Doppler was demonstrated on testing data of different tissues using different imaging settings. The fast inference time of the proposed deep generative network also allows CS Doppler to be implemented for real-time imaging. These features of CS Doppler offer a practical, fast, and robust microvascular imaging solution for many preclinical and clinical applications of Doppler ultrasound.

bioengineering↗

Curvelet Transform-based Sparsity Promoting Algorithm for Fast Ultrasound Localization Microscopy

Ultrasound localization microscopy (ULM) based on microbubble (MB) localization was recently introduced to overcome the resolution limit of conventional ultrasound. However, ULM is currently challenged by the requirement for long data acquisition times to accumulate adequate MB events to fully reconstruct vasculature. In this study, we present a curvelet transform-based sparsity promoting (CTSP) algorithm that improves ULM imaging speed by recovering missing MB localization signal from data with very short acquisition times. CTSP was first validated in a simulated microvessel model, followed by the chicken embryo chorioallantoic membrane (CAM), and finally, in the mouse brain. In the simulated microvessel study, CTSP robustly recovered the vessel model to achieve an 86.94% vessel filling percentage from a corrupted image with only 4.78% of the true vessel pixels. In the chicken embryo CAM study, CTSP effectively recovered the missing MB signal within the vasculature, leading to marked improvement in ULM imaging quality with a very short data acquisition. Taking the optical image as reference, the vessel filling percentage increased from 2.7% to 42.2% using 50ms of data acquisition after applying CTSP. CTSP used 80% less time to achieve the same 90% maximum saturation level as compared with conventional MB localization. We also applied CTSP on the microvessel flow speed maps and found that CTSP was able to use only 1.6s of microbubble data to recover flow speed images that have similar qualities as those constructed using 33.6s of data. In the mouse brain study, CTSP was able to reconstruct the majority of the cerebral vasculature using 1-2s of data acquisition. Additionally, CTSP only needed 3.2s of microbubble data to generate flow velocity maps that are comparable to those using 129.6s of data. These results suggest that CTSP can facilitate fast and robust ULM imaging especially under the circumstances of inadequate microbubble localizations.

bioengineering↗

Deep Learning-based Microbubble Localization for Ultrasound Localization Microscopy

Ultrasound localization microscopy (ULM) is an emerging vascular imaging technique that overcomes the resolution-penetration compromise of ultrasound imaging. Accurate and robust microbubble (MB) localization is essential for successful ULM. In this study, we present a deep learning (DL)- based localization technique that uses both Field-II simulation and in vivo chicken embryo chorioallantoic membrane (CAM) data for training. Both radiofrequency (RF) and in-phase quadrature (IQ) data were tested in this study. The simulation experiment shows that the proposed DL-based localization was able to reduce both missing MB localization rate and MB localization error. In general, RF data showed better performance than IQ. For the in vivo CAM study with high MB concentration, DL-based localization was able to reduce the vessel MB saturation time by more than 50% as compared to conventional localization. Additionally, we propose a DL-based framework for real-time visualization of the high-resolution microvasculature. The findings of the paper support the use of DL for more robust and faster MB localization, especially under high MB concentrations. The results indicate that further improvement could be achieved by incorporating temporal information of the MB data.

bioengineering↗

Improved Ultrasound Localization Microscopy based on Microbubble Uncoupling via Transmit Excitation (MUTE)

Ultrasound localization microscopy (ULM) demonstrates great potential for visualization of tissue microvasculature at depth with high spatial resolution. The success of ULM heavily depends on the robust localization of isolated microbubbles (MBs), which can be challenging in vivo especially within larger vessels where MBs can overlap and cluster close together. While MB dilution alleviates the issue of MB overlap to a certain extent, it drastically increases the data acquisition time needed for MBs to populate the microvasculature, which is already on the order of several minutes using recommended MB concentrations. Inspired by optical super-resolution imaging based on stimulated emission depletion (STED), here we propose a novel ULM imaging sequence based on microbubble uncoupling via transmit excitation (MUTE). MUTE "silences" MB signals by creating acoustic nulls to facilitate MB separation, which leads to robust localization of MBs especially under high concentrations. The efficiency of localization accomplished via the proposed technique was first evaluated in simulation studies with conventional ULM as a benchmark. Then an in vivo study based on the chorioallantoic membrane (CAM) of chicken embryos showed that MUTE could reduce the data acquisition time by half thanks to the enhanced MB separation and localization. Finally, the performance of MUTE was validated in an in vivo mouse brain study. These results demonstrate the high MB localization efficacy of MUTE-ULM, which contributes to a reduced data acquisition time and improved temporal resolution for ULM.

bioengineering↗

Localization free super-resolution microbubble velocimetry using a long short-term memory neural network

Ultrasound localization microscopy is a super-resolution imaging technique that exploits the unique characteristics of contrast microbubbles to side-step the fundamental trade-off between imaging resolution and penetration depth. However, the conventional reconstruction technique is confined to low microbubble concentrations to avoid localization and tracking errors. Several research groups have introduced sparsity- and deep learning-based approaches to overcome this constraint to extract useful vascular structural information from overlapping microbubble signals, but these solutions have not been demonstrated to produce blood flow velocity maps of the microcirculation. Here, we introduce Deep-SMV, a localization free super-resolution microbubble velocimetry technique, based on a long short-term memory neural network, that provides high imaging speed and robustness to high microbubble concentrations, and directly outputs blood velocity measurements at a super-resolution. Deep-SMV is trained efficiently using microbubble flow simulation on real in vivo vascular data and demonstrates real-time velocity map reconstruction suitable for functional vascular imaging and pulsatility mapping at super-resolution. The technique is successfully applied to a wide variety of imaging scenarios, include flow channel phantoms, chicken embryo chorioallantoic membranes, and mouse kidney, tumor, and brain imaging.

bioengineering↗

Contrast-enhanced sonography with biomimetic lung surfactant nanodrops

Nanodrops comprising a perfluorocarbon liquid core can be acoustically vaporized into echogenic microbubbles for ultrasound imaging. Packaging the microbubble in its condensed liquid state provides distinct advantages, including in situ activation of the acoustic signal, longer circulation persistence, and the advent of expanded diagnostic and therapeutic applications in pathologies which exhibit compromised vasculature. One obstacle to clinical translation is the inability of the limited surfactant present on the nanodrop to encapsulate the greatly expanded microbubble interface, resulting in ephemeral microbubbles with limited utility. In this study, we examine a biomimetic approach to stabilizing an expanding gas surface by employing the lung surfactant replacement, Beractant. Lung surfactant contains a suite of lipids and surfactant proteins that provides efficient shuttling of material from bilayer folds to the monolayer surface. We therefore hypothesized that Beractant would improve stability of acoustically vaporized microbubbles. To test this hypothesis, we characterized Beractant surface dilation mechanics and revealed a novel biophysical phenomenon of rapid interfacial melting, spreading and re-solidification. We then harnessed this unique spreading capability to increase the stability and echogenicity of microbubbles produced after acoustic droplet vaporization for in vivo ultrasound imaging. Such biomimetic lung surfactant-stabilized nanodrops may be useful for applications in ultrasound imaging and therapy. Graphical Abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=92 SRC="FIGDIR/small/367235v1_ufig1.gif" ALT="Figure 1"> View larger version (33K): org.highwire.dtl.DTLVardef@b6b2f4org.highwire.dtl.DTLVardef@9eb8b7org.highwire.dtl.DTLVardef@71364corg.highwire.dtl.DTLVardef@a3c41d_HPS_FORMAT_FIGEXP M_FIG C_FIG

bioengineering↗

Retinoid X receptor alpha is a spatiotemporally-specific therapeutic target for doxorubicin-induced cardiomyopathy in adult zebrafish

While the genetic suppressor screen is efficient in suggesting therapeutic genes, this strategy has yet to be successful for cardiomyopathies in vertebrates. To develop such a strategy, we recently established a mutagenesis screen platform in zebrafish for systematic discovery of genetic modifiers of doxorubicin-induced cardiomyopathy (DIC). Here, we further revealed both molecular and cellular insights of the first salutary modifier emerged from the screen, i.e. gene-breaking transposon (GBT) 0419 that affects the retinoid X receptor alpha a (rxraa) gene. First, by rescuing the mutation in tissue-specific manner with multiple Cre-loxP systems, we demonstrated that the endothelial, but not myocardial or epicardial, function of rxraa is primary to this cardioprotective effects. Next, we showed that the rxraa-associated salutary effects on DIC were conferred partially by the activation of retinoid acid (RA) signaling. Finally, we identified isotretinoin and bexarotene, 2 US Food and Drug Administration-approved RXRA agonists that are effective in treating adult zebrafish DIC when administered during the early, but not the late, phase of DIC progression. Collectively, we provided the first in vivo genetic evidence in supporting RXRA as the therapeutic target for DIC, and uncovered a previously unrecognized spatiotemporally-restricted mechanism for this gene-based therapeutic strategy. Our study also justified that searching salutary modifiers via zebrafish mutagenesis screen can be effective in discovering new therapeutic targets for cardiomyopathies.

genetics↗