A harmonized phantom MRI quality control framework identifies sources of longitudinal and multi-site variability

The shift towards open science in preclinical research requires high-quality, comparable data adhering to FAIR principles, yet rigorous quality assurance (QA) and quality control (QC) frameworks remain less established in preclinical magnetic resonance imaging (MRI) than in clinical imaging. To address this limitation, a multicenter study was conducted across 21 international laboratories using standardized commercial liquid phantoms for mouse and rat MRI setups and a harmonized acquisition protocol. Data processing was centralized using AIDAqc, an automated pipeline extracting quantitative metrics including signal-to-noise ratio (SNR), temporal SNR (tSNR), ghost-to-signal ratio (GSR), and motion-equivalent temporal instability, combined with five complementary outlier-detection algorithms. The evaluated datasets encompassed magnetic field strengths from 3.0 to 16.4 T and heterogeneous coil and acquisition configurations. In mouse phantom data, SNR and tSNR were significantly lower at 3 T than at 7 and 9.4 T, whereas artifact-related metrics did not differ significantly between field-strength groups. In rat phantom data, differences between field strengths were less pronounced. At 7 T, substantial dataset-specific differences were observed in anatomical and functional quality metrics, also among datasets using the similar coil configuration. Multicenter reference values for frequently represented 7 T configurations were established, including SNR/tSNR of 48 {+/-} 3/48 {+/-} 1 dB for mouse surface-coil datasets and 49 {+/-} 3/44 {+/-} 4 dB for rat array-coil datasets. Longitudinal anatomical SNR showed generally low variability, whereas ghosting was more variable across time. Automated outlier detection additionally identified transient acquisition instabilities that were not always apparent by visual inspection. Together, these findings show that field strength and nominal coil configuration alone do not adequately characterize MRI performance and support standardized, longitudinal phantom-based QC combined with automated analysis as a practical approach for improving the reliability, transparency, and interoperability of multicenter preclinical MRI data.

bioengineering↗

Lymph Nodes Inhibit T-cell Effector Functions Locally by Establishing Acidic Niches

Lymph nodes are an essential component of the adaptive immune response where antigen-presenting cells are closely housed with their cognate effector cells. Protection of lymph node resident cells from activated immune cells in such close quarters would need to be robust and reversible. Effector functions of T-cells are profoundly and reversibly inhibited by an acidic microenvironment. The underlying mechanisms of this inhibition are unknown, but may relate to glycolysis, which is obligatory for expression of effector functions. Here, we demonstrate that acidification rapidly and potently inhibits monocarboxylate transporter-dependent lactic acid efflux, which dually inhibits glycolysis by end-product accumulation and by reducing cytoplasmic pH. Based on the robustness of these responses, we propose that acid-evoked T-cell inhibition is physiologically important, and that lymph nodes are a natural site for such modulation. Using multiple imaging techniques, we show that paracortical T-zones of lymph nodes are highly acidic. We further show that T-cells can be activated by dendritic cells at low pH, and their effector functions are restored rapidly upon increasing pH. Thus, we describe a novel physiological mechanism whereby activated T-cells are kept in stasis by acidosis whilst resident in lymph nodes.

physiology↗