Search bioRxiv⌕ Search

Biology subjects

Lim, R.

Publications and source records attributed to Lim, R..

20 records · Page 2Linked to original sources

Reliability of dynamic network reconfiguration: Impact of code implementation, parameter selection, scan duration, and task condition

Multilayer network models have been proposed as an effective means of capturing the dynamic configuration of distributed neural circuits and quantitatively describing how communities vary over time. Beyond general insights into brain function, a growing number of studies have begun to employ these methods for the study of individual differences. However, test-retest reliabilities for multilayer network measures have yet to be fully quantified or optimized, potentially limiting their utility for individual difference studies. Here, we systematically evaluated the impact of multilayer community detection algorithms, selection of network parameters, scan duration, and task condition on test-retest reliabilities of multilayer network measures (i.e., flexibility, integration, and recruitment). A key finding was that the default method used for community detection by the popular generalized Louvain algorithm can generate erroneous results. Although available, an updated algorithm addressing this issue is yet to be broadly adopted in the neuroimaging literature. Beyond the algorithm, the present work identified parameter selection as a key determinant of test-retest reliability; however, optimization of these parameters and expected reliabilities appeared to be dataset-specific. Once parameters were optimized, consistent with findings from the static functional connectivity literature, scan duration was a much stronger determinant of reliability than scan condition. When the parameters were optimized and scan duration was sufficient, both passive (i.e., resting state, Inscapes, and movie) and active (i.e., flanker) tasks were reliable, although reliability in the movie watching condition was significantly higher than in the other three tasks. The minimal data requirement for achieving reliable measures for the movie watching condition was 20 min, and 30 min for the other three tasks. Our results caution the field against the use of default parameters without optimization based on the specific datasets to be employed - a process likely to be limited for most due to the lack of test-retest samples to enable parameter optimization. HighlightsO_LIDynamic network reliability is highly dependent on many methodological decisions C_LIO_LIThe default multilayer community detection algorithm generates erroneous results C_LIO_LIReliability-optimized intra-/inter-layer coupling parameters are dataset-dependent C_LIO_LIScan duration is a much stronger determinant of reliability than scan condition C_LIO_LIMovies are the most reliable condition, requiring at least 20 min of data C_LI

neuroscience↗

A Comparison of mRNA Sequencing with Random Primed and 3’-Directed Libraries

Deep mRNA sequencing (mRNAseq) is the state-of-the-art for whole transcriptome measurements. A key step is creating a library of cDNA sequencing fragments from RNA. This is generally done by random priming, creating multiple sequencing fragments along the length of each transcript. A 3 end-focused library approach cannot detect differential splicing, but has potentially higher throughput at lower cost (~10-fold lower), along with the ability to improve quantification by using transcript molecule counting with unique molecular identifiers (UMI) to correct for PCR bias. Here, we compare implementation of such a 3-digital gene expression (3-DGE) approach with \"conventional\" random primed mRNAseq, which has not yet been done. We find that while conventional mRNAseq detects ~15% more genes, the resulting lists of differentially expressed genes and therefore biological conclusions and gene signatures are highly concordant between the two techniques. We also find good quantitative agreement on the level of individual genes between the two techniques in terms of both read counts and fold change between two conditions. We conclude that for high-throughput applications, the potential cost savings associated with the 3-DGE approach are a very reasonable tradeoff for modest reduction in sensitivity and inability to observe alternative splicing, and should enable much larger scale studies focused on not only differential expression analysis, but also quantitative transcriptome profiling. The computational scripts and programs, along with experimental standard operating procedures used in our pipeline presented here, are freely available on our website (www.dtoxs.org).

genomics↗