Search bioRxiv⌕ Search

Biology subjects

Li, D. S.

Publications and source records attributed to Li, D. S..

4 recordsLinked to original sources

From Network Topology to Parameterization: An Optimized Model of Endothelial Mechanobiology

Endothelial cells integrate biomechanical and biochemical cues to regulate vascular function, which can be modeled using cell signaling networks. Yet, the extent to which their signaling behavior is determined by network topology versus reaction-specific parameterization remains unclear. We developed a continuous logic-based ordinary differential equation model of vascular endothelial signaling containing 70 species and 123 regulatory reactions assembled from the literature. Model predictions were evaluated against 78 literature-defined directional responses to increased wall stress, wall shear stress, hypoxia, and TNF. We first tested whether a single global parameter triplet describing reaction weight (w), Hill coefficient (n), and half-maximal activation (EC50) could reproduce these observations. Investigator-selected global parameters reproduced 62 of 78 responses (79.49%). Monte Carlo sampling of 100,000 globally constant parameter sets improved agreement to 69 of 78 responses (88.46%), indicating that network topology alone captured most qualitative signaling behavior but remained sensitive to parameter choice. Allowing reaction-specific parameters increased the best agreement to 75 of 78 responses (96.15%). We then used a genetic algorithm to identify the smallest subset of reactions requiring reaction-specific specification while retaining a common constant-parameter spine for the remainder of the network. Complete agreement (100%) with all 78 literature-defined responses was achieved with reaction-specific parameterization of only 10 of 123 reactions. The optimized model was subsequently used to simulate continuous changes in wall shear stress, revealing pathway-dependent nonlinear responses, including monotonic increases in nitric oxide and pSmad1/5, nonmonotonic responses in endothelin-1 and NF-{kappa}B, and a biphasic pSmad2/3 response. These findings show that most observed endothelial signaling behavior can be reproduced by a fixed network topology with broadly shared reaction parameters with only a limited subset of interactions requiring quantitative specialization. This framework provides a compact endothelial signaling model for investigating mechanobiological regulation and for future integration with multiscale models of vascular adaptation and disease.

bioengineering↗

Mechanisms Driving Thoracic Aortic Aneurysm Stability

Thoracic aortic aneurysms (TAAs) arise from a combination of biological and mechanical factors. Current clinical guidelines use size and rate of expansion to stratify risk, but such metrics do not predict if an aneurysm will stabilize, grow, dissect, or rupture. Computational biomechanical models can provide insights into mechanisms of aneurysm behavior that would be difficult or impossible to capture in vivo. Here, we use a constrained mixture theory of growth and remodeling to simulate lesion progression while co-varying rate-dependent parameters that contribute to the natural history of aneurysm growth. This includes insults to the material structure and mechanosensitivity of the vessel. This framework successfully simulates clinically-relevant phenotypes, including cases where lesions with initially similar degrees of dilatation or rates of expansion diverge in behavior later in their progression. By capturing this spectrum of outcomes, our framework lays a foundation for more accurate, patient-specific risk prediction and future integration of machine learning tools to accelerate translation into clinical practice.

bioengineering↗

Compensatory aortic remodeling in Marfan syndrome protects against sexually dimorphic rupture during a BAPN challenge

Transmural rupture of the aorta is responsible for significant morbidity and mortality; it occurs when wall stress exceeds local wall strength. Amongst other conditions, the aortic root and ascending aorta become vulnerable to dissection and rupture in Marfan syndrome, a connective tissue disorder that results in a progressive fragmentation and degradation of the elastic fibers of the aortic wall. Whereas competent elastic fibers are critical for aortic functionality, cross-linked collagen fibers endow the aorta with its stiffness and strength. In this paper, we contrast progressive degeneration of the ascending aorta in male and female Marfan and wild-type mice, with and without chronic exposure to a potent inhibitor of lysyl oxidase ({beta}-aminopropionitrile, or BAPN), to examine effects of extracellular matrix cross-linking in aortic dilatation and rupture. We found a strong sexual dimorphism in aortic dilatation in Marfan mice and aortic rupture in wild-type mice, but also a compensatory remodeling of the aorta that protected the Marfan aorta against lethal rupture despite a strong BAPN challenge. This compensation appears to be mediated via increased lysyl oxidase in the female and especially male Marfan aorta, resulting in improved collagen fiber stability and integrity, particularly of fibril bundles in the adventitia.

bioengineering↗

Real-time spectroscopic photoacoustic/ultrasound (PAUS) scanning with simultaneous fluence compensation and motion correction for quantitative molecular imaging

For over two decades photoacoustic (PA) imaging has been tested clinically, but successful human trials have been minimal. To enable quantitative clinical spectroscopy, the fundamental issues of wavelength-dependent fluence variations and inter-wavelength motion must be overcome. Here we propose a new real-time, spectroscopic photoacoustic/ultrasound (PAUS) imaging approach using a compact, 1-kHz rate wavelength-tunable laser. Instead of illuminating tissue over a large area, the fiber-optic delivery system surrounding an US array sequentially scans a narrow laser beam, with partial PA image reconstruction for each laser pulse. The final image is then formed by coherently summing partial images at a 50-Hz video rate. This scheme enables (i) automatic laser-fluence compensation in spectroscopic PA imaging and (ii) inter-wavelength motion correction using US speckle tracking, which have never been shown before in real-time systems. The 50-Hz video rate PAUS system is demonstrated in vivo using a murine model of drug delivery monitoring.

bioengineering↗