Search bioRxiv⌕ Search

Biology subjects

Kulyk, O.

Publications and source records attributed to Kulyk, O..

2 recordsLinked to original sources

Observation of a single protein by ultrafast X-ray diffraction

The idea of using ultrashort X-ray pulses to obtain images of single proteins frozen in time has fascinated and inspired many. It was one of the arguments for building X-ray free-electron lasers. According to theory1, the extremely intense pulses provide sufficient signal to dispense with using crystals as an amplifier, and the ultrashort pulse duration permits capturing the diffraction data before the sample inevitably explodes2. This was first demonstrated on biological samples a decade ago on the giant mimivirus3. Since then a large collaboration4 has been pushing the limit of the smallest sample that can be imaged5,6. The ability to capture snapshots on the timescale of atomic vibrations, while keeping the sample at room temperature, may allow probing the entire conformational phase space of macromolecules. Here we show the first observation of an X-ray diffraction pattern from a single protein, that of Escherichia coli GroEL which at 14 nm in diameter7 is the smallest biological sample ever imaged by X-rays, and demonstrate that the concept of diffraction before destruction extends to single proteins. From the pattern, it is possible to determine the approximate orientation of the protein. Our experiment demonstrates the feasibility of ultrafast imaging of single proteins, opening the way to single-molecule time-resolved studies on the femtosecond timescale.

biophysics↗

Electrospray sample injection for single-particle imaging with X-ray lasers

The possibility of imaging single proteins constitutes an exciting challenge for X-ray lasers. Despite encouraging results on large particles, imaging small particles has proven to be difficult for two reasons: not quite high enough pulse intensity from currently available X-ray lasers and, as we demonstrate here, contamination of the aerosolised molecules by non-volatile contaminants in the solution. The amount of contamination on the sample depends on the initial droplet-size during aerosolisation. Here we show that with our electrospray injector we can decrease the size of aerosol droplets and demonstrate virtually contaminant-free sample delivery of organelles, small virions, and proteins. The results presented here, together with the increased performance of next generation X-ray lasers, constitute an important stepping stone towards the ultimate goal of protein structure determination from imaging at room temperature and high temporal resolution.

biophysics↗