Search bioRxiv⌕ Search

Biology subjects

Korostin, D.

Publications and source records attributed to Korostin, D..

11 recordsLinked to original sources

PRECISE EXOME ANALYSIS OF BLASTOCYST BIOPSY SCALE SAMPLES USING PRIMARY TEMPLATE-DIRECTED AMPLIFICATION

This study evaluates primary template-directed amplification (PTA) for whole exome sequencing (WES) on small fibroblast cell groups, mimicking the limited cell quantities typical of trophectoderm embryo biopsies. PTAs consistent amplification reduces allelic dropout (ADO) and impoves uniform coverage, overcoming challenges associated with conventional methods such as multiple displacement amplification (MDA). Using fibroblast samples alongside well-characterised genomic references (E701, NA12878), we benchmarked PTA-WES, achieving 97.5% target region coverage at 10x, meeting American College of Medical Genetics and Genomics (ACMG) standards. Preliminary results from embryo biopsies sequenced with PTA-WES showed a median coverage of 102x, significantly improving upon the variability and coverage gaps observed in MDA-WES. The findings support PTAs potential to enhance the clinical applicability of WES for preimplantation genetic testing for monogenic disorders (PGT-M), expanding capabilities to detect inherited and de novo mutations in embryos. Further optimisation and variant detection analyses are planned to evaluate PTAs robustness for routine clinical use.

genetics↗

Experience in developing the human genome standard E701

The first Russian human genome standard E701 was developed through a collaborative research involving four laboratories: Pirogov Russian National Research Medical University, National Medical Research Center for Obstetrics, Gynecology and Perinatology named after Academician V.I.Kulakov, National Research Center Kurchatov Institute, and National Medical Research Radiological Centre. Whole-genome sequencing of short reads on various platforms (MGI Tech, Illumina) and alignment to the reference human genome GRCh38.p14 were performed for the E701 sample. Subsequently, 3842877 high confidence genomic variants were identified, which can be used as a standard for calculating statistical quality metrics while analyzing sequencing data. Furthermore, 9096 biallelic variants were identified on the autosomes and the X chromosome, with a minor allele frequency exceeding 0.4. Additionally, mitochondrial DNA sequencing was performed with the breadth of coverage over 99.9% at 1000X.

genomics↗

Comparative evaluation of four exome enrichment solutions in 2024: Agilent, Roche, Vazyme and Nanodigmbio

Whole exome sequencing (WES) is essential for identifying genetic variants linked to diseases. This study compares available to date four exome enrichment kits: Agilent SureSelect Human All Exon v8, Roche KAPA HyperExome Probes, Vazyme VAHTS Target Capture Core Exome Panel, and Nanodigmbio NEXome Plus Panel v1. We evaluated target design, coverage statistics, and variant calling accuracy across these four different exome capture products. All kits showed high coverage completeness, with mean x10 coverage exceeding 97.5% and x20 coverage above 95%. Roche exhibited the most uniform coverage, indicated by the lowest fold-80 scores, while Nanodigmbio had more on-target reads due to fewer off-target reads. Variant calling performance, evaluated using in-lab standard E701 DNA sample, showed high recall rates for all kits, especially Agilent v8. All kits achieved an F-measure above 95.87%. Nanodigmbio had the highest precision with the fewest false positives but a slightly lower F-measure than other kits. This study also highlights the performance of new Chinese solutions from Vazyme and Nanodigmbio, which were comparable to Agilent v8 and Roche KAPA kits. These findings assist researchers and clinicians in selecting appropriate exome capture solutions.

genomics↗

Benchmarking DNA Isolation Methods for Marine Metagenomics Studies

Metagenomics is a powerful tool to study marine microbial communities. However, obtaining high-quality environmental DNA suitable for downstream sequencing applications is a challenging task. The quality and quantity of isolated DNA heavily depend on the choice of purification procedure and the type of sample. Selection of an appropriate DNA isolation method for a new type of material often entails a lengthy trial and error process. Further, each DNA purification approach introduces biases and thus affects the composition of the studied community. To account for these problems and biases, we systematically investigated efficiency of DNA purification from three types of samples (water, sea sediment, and digestive tract of a model invertebrate Magallana gigas) with eight commercially available microbial DNA isolation kits. For each kit-sample combination we measured the quantity of purified DNA, extent of DNA fragmentation, the presence of PCR-inhibiting contaminants, admixture of eukaryotic DNA, alpha-diversity, and reproducibility of the resulting community composition based on 16S rRNA amplicons sequencing. Additionally, we determined a "kitome", e.g., a set of contaminating taxa inherent for each type of purification kit used. The resulting matrix of evaluated parameters allows one to select the best DNA purification procedure for a given type of sample.

bioinformatics↗

DESIGNING OF CUSTOM BARCODES FOR SEQUENCING ON THE MGI PLATFORM

The recently launched MGI platform (DNBSEQ-G50, -G400 and -T7 sequencers) has been gaining popularity for next-generation sequencing. However, the barcode set for library preparation provided by the manufacturer has certain limitations on the number of samples that can be sequenced at a time and the compatibility of barcodes from different or incomplete sets as well as a ratio between the samples. In this paper, we present a protocol for designing custom barcodes expanding the pre-existing barcode set and demonstrate its performance on the MGI Tech Co. Ltd. (China) machines. We developed a universal "quad method" which allows for simultaneous sequencing of any number of samples up to 252 per lane which is multiple of 4 or 4n+2. Here, we describe this method, its analysis, verification, and integration into the sequencing as well as its validation for sequencing using the DNBSEQ G-400 machine.

genomics↗

Performance Comparison Of Agilent New SureSelect All Exon v8 Probes With v7 Probes For Exome Sequencing

Exome sequencing may become routine in health care it increases the chance of pinpointing the genetic cause of an individual patients condition and thus making an accurate diagnosis. It is important for facilities providing genetic services to keep track of changes in the technology of exome capture in order to maximize throughput while reducing cost per sample. In this study, we focused on comparing the newly released exome probe set Agilent SureSelect Human All Exon v8 and the previous probe set v7. In preparation for higher throughput of exome sequencing using the DNBSEQ-G400, we evaluated target design, coverage statistics, and variants across these two different exome capture products. Although the target size of the v8 design has not changed much compared to the v7 design (35.24 Mb vs 35.8 Mb), the v8 probe design allows you to call more of SNVs (+3.06%) and indels (+8.49%) with the same number of raw reads per sample on the common target regions (34.84 Mb). Our results suggest that the new Agilent v8 probe set for exome sequencing yields better data quality than the current Agilent v7 set.

genomics↗

SYSTEM ANALYSIS OF THE SEQUENCING QUALITY OF HUMAN WHOLE EXOME SAMPLES ON BGI NGS PLATFORM

Human whole exome sequencing (WES) is now the standard for most medical genetics applications worldwide. The leaders are manufacturers of enrichment kits that base their protocols on a hybridization approach using cRNA or cDNA biotinylated samples specific to regions of interest in the genome. Recently, platforms from the Chinese company MGI Tech have been successfully promoted in the markets of many countries in Europe and Asia. There is no longer any question about their reliability and the quality of the data obtained. However, very few task-specific kits for WES, in particular, are presented for these sequencers. We have developed our solution for library pre-capture pooling and exome enrichment using Agilent probes. In this work, we demonstrate on a set of standard benchmark samples from the Platinum Genome Collection that our protocol, called "RSMU_exome", is superior to the kit from MGI Tech in qualitative and quantitative terms. It allows detecting more SNVs and CNVs with superior sensitivity and specificity values, generates fewer PCR duplicates, allows more samples to be pooled in a single enrichment, and requires less raw data to produce results comparable to the MGI Tech solution. Also, our protocol is significantly cheaper than the kit from the Chinese manufacturer.

genomics↗

Runcer-Necromancer: A Method To Rescue Data From An Interrupted Run On MGISEQ-2000

During the sequencing process, problems can occur with any device including the MGISEQ-2000 (DNBSEQ-G400) platform. We encountered a power outage that resulted in a temporary shutdown of a sequencer in the middle of the run. Since barcode reading in MGISEQ-2000 takes place at the end of the run, it was impossible to use non-demultiplexed raw data. We decided to completely use up the same cartridge with reagents and flow cell loaded with DNB and started a new run in a shortened custom mode. We figured out how the MGISEQ-2000 converts preliminary data in .cal format into .fastq files and wrote a script named "Runcer-Necromacer" for merging .fastq files based on the analysis of their headers (available online: https://github.com/genomecenter/runcer-necromancer). Read merging proved to be possible because the MGISEQ-2000 flow cell has a patterned structure and each DNB has invariable coordinates on it, regardless of its position on the flow cell stage. We demonstrated the correctness of data merging by comparing sample analysis results with previously obtained .fastq files for them. Thus, we confirmed that it is possible to restart the device and save both parts of the interrupted run.

bioinformatics↗

BC-store: a program for mgiseq barcode sets analysis

Here we present the devised BC-store - a program for analyzing and selecting sets of barcodes for sequencing on platforms manufactured by MGI Tech (China). The app is available as an open source in Python3 and as a desktop version. The application allows analyzing the compatibility of barcodes on a single lane of a flow cell in a set in the case of equal and arbitrary fractions. In addition, with the help of this tool barcodes can be added to an existing set with custom share options. In this paper we describe how BC-store works for different tasks and consider the effectiveness of using BC-store in sequence lab routine tasks. Author summaryThe performance of modern NGS machines allows considerable amount of data to be obtained which exceed the data required for one specific sample. To pool multiple samples on a single lane of the flow cell, barcoding is used - adapters carrying a unique nucleotide sequence are introduced by ligation [1]. Adapters are sequenced from their specific primers. Their sequences are used for demultiplexing the sequencing results for individual fastq files by programs like zebracall [2] or bcl2fastq [3]. The task of selecting the adapters for a set is similar to sequencing low diversity libraries [4]: if all adapters on the lane have the same nucleotide during this sequencing cycle, the quality of its reading drops dramatically. Therefore, manufacturers recommend grouping the adapters by sets. However, the sets offered by MGI Tech [5] are far from routine practice, as they do not allow for non-equimolar sample pooling by default, and they have other disadvantages (more on them later in the text). To overcome these problems, we created the BC-store program, which allows analyzing the sets of MGI Tech barcodes entered by the user to be further used in sequencing. This tool also provides the opportunity to vary the number of simultaneously sequenced samples, to use reagents more efficiently, and, as a result, to correctly distribute reads across samples, which helps to increase both the quality of sequencing and the level of data interpretation.

bioinformatics↗

Comparative analysis of novel MGISEQ-2000 sequencing platform vs Illumina HiSeq 2500 for whole-genome sequencing

BackgroundMGISEQ-2000 developed by MGI Tech Co. Ltd. (a subsidiary of the BGI Group) is a new competitor of such next-generation sequencing platforms as NovaSeq and HiSeq (Illumina). Its sequencing principle is based on the DNB and cPAS technologies, which were also used in the previous version of the BGISEQ-500 device. However, the reagents for MGISEQ-2000 have been refined and the platform utilizes updated software. The cPAS method is an advanced technology based on cPAL previously created by Complete Genomics. ResultIn this paper, the authors compare the results of the whole-genome sequencing of a DNA sample from a Russian female donor performed on MGISEQ-2000 and Illumina HiSeq 2500 (both PE150). Two platforms were compared in terms of sequencing quality, number of errors and performance. Additionally, we performed variant calling using four different software packages: Samtools mpileaup, Strelka2, Sentieon, and GATK. The accuracy of single nucleotide polymorphism (SNP) detection was similar in the data generated by MGISEQ-2000 and HiSeq 2500, which was used as a reference. At the same time, a separate indel analysis of the overall error rate revealed similar FPR values and lower sensitivity. Conclusionsit may be concluded with confidence that the data generated by the analyzed sequencing systems is characterized by comparable magnitudes of error and that MGISEQ-2000 can be used for a wide range of research tasks on par with HiSeq 2500.

genomics↗