High Accuracy Fluorescence Guided Focused Ion Beam Milling

Cryo-electron tomography (cryo-ET) is a powerful approach for visualizing macromolecular structures directly within cells, but its broader application is limited by the difficulty of reliably targeting specific structures during sample preparation. In particular, capturing small or rare objects within cryo-focused ion beam (cryo-FIB) milled lamellae remains a major bottleneck. Here, we present two fluorescence-guided cryo-FIB milling workflows that overcome key sources of targeting error and enable routine capture of structures across a broad range of spatial scales. For larger targets (>500 nm), we present an improved registration-based strategy combining FIB-milled fiducials with depth correction for refractive index mismatch. For smaller targets (150-500 nm), we implement real-time fluorescence guided milling on a commercially available cryo-FIB-SEM platform enabling consistent recovery of small, low-copy organelles such as centrosomes and primary cilia. Both workflows are implemented in a new open-source package fibsemOS and together expand the range of cellular structures accessible to cryo-ET and establish a broadly deployable framework for targeted in situ structural biology.

cell biology↗

Exploring shaped focused ion beams for lamella preparation

Focused ion beams (FIB) are widely used instruments in transmission electron microscopy (TEM) sample preparation across scientific disciplines. Generally, site-specific ablation of material is achieved by scanning a highly focused probe across a selected area, leading to the removal of material. However, the geometries of TEM lamellae milled with the FIB are usually highly non-isometric, with their thickness generally being orders of magnitude smaller than their width and length. Here, we explore a changed probe shape for milling. Instead of using a Gaussian-like spot probe ion beam, we characterize the use of the stigmator as quasi-cylindrical lens to create a highly astigmatic beam that we term ion knife. Using the ion knife allows for material ablation by spreading the current over a larger area and changes the dimension of the probe with an anisotropic change in apparent beam resolution, as observed in spot burn cross-sections. We demonstrate a method to approximate beam shapes by imaging that allows for convenient alignment of parameters for beam shaping. Finally, exploring shaped probes in cryogenic lamella preparation, we demonstrate the feasibility of cellular lamella milling and sectioning of cryo-lift-out volumes with the ion knife.

biophysics↗

Making plant tissue accessible for cryo-electron tomography

Cryo-Electron Tomography (cryo-ET) allows to visualize the molecular architecture of pristinely preserved cells and tissues. The workflow of sample preparation for cryo-ET is rather complex; it involves vitrification by rapid freezing followed by cryo-Focused Ion Beam (FIB) milling rendering the volumes of interest thin enough for cryo-ET data acquisition. The established protocols for single cells grown on or deposited on EM-grids are not suitable for multicellular plant tissues. Plunge-freezing does not yield vitrified samples in most cases and must be replaced by high-pressure freezing. This, in turn, necessitates extensive modifications of the subsequent FIB milling procedures. In this communication we describe procedures for sample screening, targeted FIB milling guided by cryo-fluorescence microscopy and a novel lamella trimming step that allows to obtain homogenously thin lamellae suitable for cryo-ET. We have tested all the steps along the workflow with a variety of plant tissues including the moss Physcomitrium patens and tissues of Arabidopsis thaliana and Limonium bicolor. We could demonstrate that the workflow optimized for plant tissues allows to attain subnanometer resolution in cases where subtomogram averaging is applicable.

plant biology↗

The small GTPase Ran defines Nuclear Pore Complex asymmetry

Nuclear pore complexes (NPCs) bridge across the nuclear envelope and mediate nucleocytoplasmic exchange. They consist of hundreds of nucleoporin building blocks and exemplify the structural complexity of macromolecular assemblies. To ensure transport directionality, different nucleoporin complexes are attached to the cytosolic and nuclear face of the NPC. How those asymmetric structures are faithfully assembled onto the symmetric scaffold architecture that exposes the same interaction surfaces to either side, remained enigmatic. Here we combine cryo-electron tomography, subtomogram averaging, and template matching with live cell imaging to address this question in budding yeast and Drosophila melanogaster. We genetically induce ectopic nuclear pores and show that pores outside the nuclear envelope are symmetric. We furthermore demonstrate that the peripheral NPC configuration depends on the nucleotide state of the small GTPase Ran. Our findings indicate that the nuclear transport system is self-regulatory, namely the same molecular mechanism controls both transport and transport channel composition.

cell biology↗

Reduction of SEM charging artefacts in native cryogenic biological samples.

Scanning electron microscopy (SEM) of frozen-hydrated biological samples allows imaging of subcellular structures at the mesoscale in their native state. Combined with focused ion beam milling (FIB), serial FIB/SEM can be used to build a 3-dimensional picture of cells and tissues. The correlation of specific regions of interest with cryo-electron microscopy (cryoEM) can additionally enable subsequent high-resolution analysis. However, the adoption of serial FIB/SEM imaging-based methods is limited due to artefacts arising from insulating areas of cryogenically preserved samples. Here, we demonstrate the use of interleaved scanning to reduce charging artefacts, allowing the observation of biological features that otherwise would be masked or perturbed. We apply our method to samples where inherent features are not visible. These examples include membrane contact sites within mammalian cells, visualisation of the degradation compartment in the algae E.gracilis and observation of a network of membranes within different types of axons in an adult mouse cortex. We further propose an alternative scanning method that could also be widely applicable to imaging any non-conductive.

cell biology↗

In-cell structure and snapshots of copia retrotransposons in intact tissue by cryo-electron tomography

Long terminal repeat (LTR) retrotransposons belong to the transposable elements (TE), autonomously replicating genetic elements that integrate into the hosts genome. LTR retrotransposons represent a major component of genomes across the tree of life; some derived sequences have even been domesticated by the host to perform cellular functions in essential processes such as development. Among animals, Drosophila melanogaster serves as an important model organism for TE research, harboring several LTR retrotransposons, including the Ty1-copia family, which is evolutionarily related to retroviruses and forms virus-like particles (VLPs). The architectural organization of copia VLPs in situ has remained unknown. In this study, we use cryo-FIB milling and lift-out approaches to visualize copia VLPs in isolated ovarian cells and intact egg chambers and resolve the in situ copia capsid structure to 7.7 [A] resolution by cryo-ET. While cytosolic copia VLPs vary in size, nuclear VLPs are homogenous and form densely packed clusters, supporting a model in which nuclear import acts as a size selector. By analyzing flies deficient in the TE-suppressing PIWI-piRNA pathway, we observe a change in copia localization from cytosolic to nuclear during spermatogenesis in testes. Our findings provide insights into the cellular structural biology of an active LTR retrotransposon and shed light on the replication cycle of copia in the context of host gametogenesis.

biophysics↗

Serial Lift-Out - Sampling the Molecular Anatomy of Whole Organisms

Cryo-focused ion beam milling of frozen-hydrated cells and subsequent cryo-electron tomography (cryo-ET) has enabled the structural elucidation of macromolecular complexes directly inside cells. Application of the technique to multicellular organisms and tissues, however, is still limited by sample preparation. While high-pressure freezing enables the vitrification of thicker samples, it prolongs subsequent preparation due to increased thinning times and the need for extraction procedures. Additionally, thinning removes large portions of the specimen, restricting the imageable volume to the thickness of the final lamella, typically < 300 nm. Here, we introduce Serial Lift-Out, an enhanced lift-out technique that increases throughput and obtainable contextual information by preparing multiple sections from single transfers. We apply Serial Lift-Out to C. elegans L1 larvae yielding a cryo-ET dataset sampling the worms anterior-posterior axis and resolve its ribosome structure to 7 [A], illustrating how Serial Lift-Out enables the study of multicellular molecular anatomy.

biophysics↗

Cryo-plasma FIB/SEM volume imaging of biological specimens

Serial focussed ion beam scanning electron microscopy (FIB/SEM) enables imaging and assessment of sub-cellular structures on the mesoscale (10 nm to 10 m). When applied to vitrified samples, serial FIB/SEM is also a means to target specific structures in cells and tissues while maintaining constituents hydration shells for in-situ structural biology downstream. However, the application of serial FIB/SEM imaging of non-stained cryogenic biological samples is limited due to low contrast, curtaining and charging artefacts. We address these challenges using a cryogenic plasma FIB/SEM (cryo-pFIB/SEM). We evaluated the choice of plasma ion source and imaging regimes to produce high quality SEM images of a range of different biological samples. Using an automated workflow we produced three dimensional volumes of bacteria, human cells, and tissue, and calculated estimates for their resolution, typically achieving 20 to 50 nm. Additionally, a tag-free tool is needed to drive the application of in situ structural biology towards tissue. The combination of serial FIB/SEM with plasmabased ion sources promises a framework for targeting specific features in bulk-frozen samples (>100 m) to produce lamella for cryogenic electron tomography.

cell biology↗

Optimizing Cryo-FIB Lamellas for sub-5 Angstrom in situ Structural Biology

We here present a method based on metallic platinum sputtering that can substantially enhance the quality of subtomogram averages from lamellas and thereby reduce the number of particles needed for high-resolution subtomogram averaging. We provide evidence for the physical background of this improvement and demonstrate its usefulness by producing sub-5[A] ribosome averages from yeast.

molecular biology↗

Allosteric control of Ubp6 and the proteasome via a bidirectional switch

The proteasome is the principal cellular protease, and recognizes target proteins that have been covalently marked by ubiquitin chains. The ubiquitin signal is subject to rapid editing at the proteasome, allowing it to reject substrates based on topological features of their attached ubiquitin chains. Editing is mediated by a key regulator of the proteasome, deubiquitinating enzyme Ubp6. The proteasome activates Ubp6, whereas Ubp6 inhibits the proteasome-both by deubiquitinating proteasome-bound ubiquitin conjugates, and through a noncatalytic effect that does not involve deubiquitination. We report mutants in both Ubp6 and proteasome subunit Rpt1 that abrogate Ubp6 activation. The Ubp6 mutations fall within its ILR element, defined here, which is conserved from yeast to mammals. The ILR is a component of the BL1 blocking loop, other parts of which obstruct ubiquitin access to the catalytic groove in free Ubp6. Rpt1 docking at the ILR opens the catalytic groove by rearranging not only BL1 but also a novel network of three directly interconnected active-site-blocking loops. Ubp6 activation and noncatalytic proteasome inhibition by Ubp6 are linked in that they were eliminated by the same Ubp6 and Rpt1 mutations. Ubp6 and ubiquitin together drive the proteasome into a unique conformational state associated with proteasome inhibition. Our results identify a multicomponent allosteric switch that exerts simultaneous control over the activity of both Ubp6 and the proteasome, and suggest that their active states are in general mutually exclusive. The findings lead to a new paradigm for allosteric control of deubiquitinating enzymes.

biochemistry↗

A Modular Platform for Streamlining Automated Cryo-FIB Workflows

Lamella micromachining by focused ion beam milling at cryogenic temperature (cryo-FIB) has matured into a preparation method widely used for cellular cryo-electron tomography. Due to the limited ablation rates of low Ga+ ion beam currents required to maintain the structural integrity of vitreous specimens, current preparation protocols are time-consuming and labor intensive. The improved stability of new generation cryo-FIB instruments now enables automated operations. Here, we present an open-source software tool, SerialFIB, for creating automated and customizable cryo-FIB preparation protocols. The software encompasses a graphical user interface for easy execution of routine lamellae preparations, a scripting module compatible with available python packages, and interfaces with 3-dimensional correlative light and electron microscopy (CLEM) tools. The software enables the streamlining of advanced cryo-FIB protocols such as multi-modal imaging, CLEM guided preparation and in situ lamella lift-out procedures. Our software therefore provides a foundation for further development of advanced cryogenic imaging and sample preparation protocols.

biophysics↗

Structural basis for VIPP1 oligomerization and maintenance of thylakoid membrane integrity

Vesicle-inducing protein in plastids (VIPP1) is essential for the biogenesis and maintenance of thylakoid membranes, which transform light into life. However, it is unknown how VIPP1 performs its vital membrane-shaping function. Here, we use cryo-electron microscopy to determine structures of cyanobacterial VIPP1 rings, revealing how VIPP1 monomers flex and interweave to form basket-like assemblies of different symmetries. Three VIPP1 monomers together coordinate a non-canonical nucleotide binding pocket that is required for VIPP1 oligomerization. Inside the rings lumen, amphipathic helices from each monomer align to form large hydrophobic columns, enabling VIPP1 to bind and curve membranes. In vivo point mutations in these hydrophobic surfaces cause extreme thylakoid swelling under high light, indicating an essential role of VIPP1 lipid binding in resisting stress-induced damage. Our study provides a structural basis for understanding how the oligomerization of VIPP1 drives the biogenesis of thylakoid membranes and protects these life-giving membranes from environmental stress.

plant biology↗

A streamlined workflow for automated cryo focused ion beam milling

Cryo-electron tomography is an emerging technique to study the cellular architecture and the structure of proteins at high resolution in situ. Most biological specimens are too thick to be directly investigated and are therefore thinned by milling with a focused ion beam under cryogenic conditions. This procedure is prone to frost and amorphous ice depositions which makes it a tedious process, leading to suboptimal results especially when larger batches are milled. Here, we present new hardware that overcomes the current limitations. We developed a new glove box and a high vacuum cryo transfer system and installed a stage heater, a cryo-shield and a cryo-shutter in the FIB milling microscope. This tremendously reduces the ice depositions during transfer and milling, and simplifies the handling of the sample. In addition, we tested a new software application that automates the key milling steps. Together, these improvements allow for high-quality, high-throughput cryo-FIB milling.

molecular biology↗

A low-cost fluorescence reader for in vitro transcription and nucleic acid detection with Cas13a

Point-of-care testing (POCT) in low-resource settings requires tools that can operate independent of typical laboratory infrastructure. Due to its favorable signal-to-background ratio, a wide variety of biomedical tests utilize fluorescence as a readout. However, fluorescence techniques often require expensive or complex instrumentation and can be difficult to adapt for POCT. To address this issue, we developed a pocket-sized fluorescence detector costing less than $15 that is easy to manufacture and can operate in low-resource settings. It is built from standard electronic components, including an LED and a light dependent resistor, filter foils and 3D printed parts, and reliably detected less than 10 nM fluorescein concentrations (with a lower limit of detection of {approx}6.8 nM), which is sufficient to follow typical biochemical reactions used in POCT applications. All assays are conducted on filter paper, which allows for a flat detector architecture to improve signal collection. We validate the device by quantifying in vitro RNA transcription and also demonstrate sequence-specific detection of target RNAs in the nanomolar range using a Cas13a-based fluorescence assay. Cas13a is a RNA-guided, RNA-targeting CRISPR effector with promiscuous RNase activity upon recognition of its RNA target. Cas13a sensing is highly specific and adaptable and in combination with our detector represents a promising approach for nucleic acid POCT. Furthermore, our open-source device architecture could be a valuable educational tool that integrates hardware, software and biochemistry concepts.

bioengineering↗