Search bioRxiv⌕ Search

Biology subjects

Khavnekar, S.

Publications and source records attributed to Khavnekar, S..

9 recordsLinked to original sources

Towards community-driven visual proteomics with large-scale cryo-electron tomography of Chlamydomonas reinhardtii

In situ cryo-electron tomography (cryo-ET) has emerged as the method of choice to investigate structures of biomolecules in their native context. However, challenges remain in the efficient production of large-scale cryo-ET datasets, as well as the community sharing of this information-rich data. Here, we applied a cryogenic plasma-based focused ion beam (cryo-PFIB) instrument for high-throughput milling of the green alga Chlamydomonas reinhardtii, a useful model organism for in situ visualization of numerous fundamental cellular processes. Combining cryo-PFIB sample preparation with recent advances in cryo-ET data acquisition and processing, we generated a dataset of 1829 reconstructed and annotated tomograms, which we provide as a community resource to drive method development and inspire biological discovery. To assay the quality of this dataset, we performed subtomogram averaging (STA) of both soluble and membrane-bound complexes ranging in size from >3 MDa to [~]200 kDa, including 80S ribosomes, Rubisco, nucleosomes, microtubules, clathrin, photosystem II, and mitochondrial ATP synthase. The majority of these density maps reached sub-nanometer resolution, demonstrating the potential of this C. reinhardtii dataset, as well as the promise of modern cryo-ET workflows and open data sharing towards visual proteomics.

cell biology↗

An approach for coherent periodogram averaging of tilt-series data for improved CTF estimation

Cryo-electron microscopy (cryo-EM) has become an indispensable technique for determining three-dimensional structures of biological macromolecules. A critical aspect of achieving high-resolution cryo-EM reconstructions is accurately determining and correcting for the microscopes contrast transfer function (CTF). The CTF introduces defocus-dependent distortions during imaging; if not properly accounted for, the CTF can distort features in and limit the resolution of 3D reconstructions. For tilt-series data used in cryo-electron tomography (cryo-ET), CTF estimation becomes even more challenging due to the tilt of the specimen, which introduces a defocus gradient across the field of view, as well as the low dose and signal in individual tilt images. Here, we describe a simple algorithm to improve the accuracy of CTF estimation of tilted images by leveraging the tilt-series alignment parameters determined for tomographic reconstruction to explicitly account for the tilted specimen geometry. In brief, each tilt image is divided into patches, each of which are then stretched according to their defocus shift. These are then summed to provide a coherent power spectra at the tilt axis, which can then be used in standard CTF estimation algorithms. This uses all the data in each image to enhance the visibility of Thon rings, thereby improving high-resolution CTF estimation and subsequent enhancements in the resolution of subtomogram averages.

molecular biology↗

Sub-3 A resolution protein structure determination by single-particle cryo-EM at 100 keV

Cryo-electron microscopy (cryo-EM) has revolutionized structural biology by providing high-resolution insights into biological macromolecules. Here, we present sub-3 [A] resolution structures determined using the 100 keV Tundra cryogenic transmission electron microscope (cryo-TEM), equipped with the newly developed Falcon C direct electron detector (DED). Our results demonstrate that this lower voltage microscope, when combined with advanced electron optics and detectors, can achieve high-resolution reconstructions that were previously only attainable with higher voltage systems. The implementation of an extreme-brightness field emission gun (XFEG) and an SP-TWIN objective lens significantly enhanced the spatial and temporal coherence of the system. Furthermore, the semi-automated sample loader minimized contamination and drift, allowing extended data collection sessions without manual intervention. The high detective quantum efficiency (DQE) of Falcon C further improved the signal-to-noise ratio, which is critical for achieving high-resolution structures. We validated the performance of this microscope by determining the structures of various biological samples, including apoferritin, T20S proteasome, GABAA receptor, haemoglobin, and human transthyretin ranging in size from 440 kDa to 50 kDa. The highest resolutions achieved were 2.1 [A] for apoferritin, 2.7 [A] for the 20S proteasome, 2.8 [A] for the GABAA receptor, 5.0 [A] for haemoglobin, and 3.5 [A] for transthyretin. We also explored a larger specimen, a 3.9 MDa Adeno-associated virus (AAV9) capsid and resolved it a 2.8 [A]. This work highlights the potential of 100 keV TEMs to make high-resolution cryo-EM more accessible to the structural biology community. Furthermore, it sets a precedent for the use of lower voltage TEMs in routine cryo-EM studies, not only for screening grids for single particle analysis but also for achieving high-resolution structures of protein samples.

biophysics↗

In-cell architecture of the mitochondrial respiratory chain

Mitochondria produce energy through oxidative phosphorylation, carried out by five membrane-bound complexes collectively known as the respiratory chain. These complexes work in concert to transfer electrons and pump protons, leading to ATP regeneration. The precise organization of these complexes in native cells is debated, notably their assembly into higher-order supercomplexes called respirasomes. Here, we use in situ cryo-electron tomography to visualize the native structures and organization of several major mitochondrial complexes inside Chlamydomonas reinhardtii cells. ATP synthases and respiratory complexes are segregated into curved and flat crista membrane domains, respectively. Respiratory complexes I, III, and IV assemble into a single type of respirasome, from which we determined a native 5 [A]-resolution structure showing the binding of electron carrier cytochrome c. Combined with single-particle cryo-electron microscopy reconstruction at 2.4 [A] resolution, we assemble a detailed model of how the respiratory complexes interact with each other inside native mitochondria.

molecular biology↗

TOMOMAN: a software package for large scale cryo-electron tomography data preprocessing, community data sharing, and collaborative computing

Cryo-electron tomography (cryo-ET) and subtomogram averaging (STA) are becoming the preferred methodologies for investigating subcellular and macromolecular structures in native or near-native environments. While cryo-ET is amenable to a wide range of biological problems, these problems often have data processing requirements that need to be individually optimized, precluding the notion of a one-size-fits-all processing pipeline. Cryo-ET data processing is also becoming progressively more complex due to an increasing number of packages for each processing step. Though each package has its own strengths and weaknesses, independent development and different data formats makes them difficult to interface with one another. TOMOMAN (TOMOgram MANager) is an extensible package for streamlining the interoperability of packages, enabling users to develop project-specific processing workflows. TOMOMAN does this by maintaining an internal metadata format and wrapping external packages to manage and perform preprocessing, from raw tilt-series data to reconstructed tomograms. TOMOMAN can also export this metadata between various STA packages. TOMOMAN also includes tools for archiving projects to data repositories; allowing subsequent users to download TOMOMAN projects and directly resume processing where it was previously left off. By tracking essential metadata, TOMOMAN streamlines data sharing, which improves reproducibility of published results, reduces computational costs by minimizing reprocessing, and enables distributed cryo-ET projects between multiple groups and institutions. TOMOMAN provides a way for users to test different software packages to develop processing workflows that meet the specific needs of their biological questions and to distribute their results with the broader scientific community.

molecular biology↗

STOPGAP, an open-source package for template matching, subtomogram alignment, and classification

Cryo-electron tomography (cryo-ET) enables molecular-resolution 3D imaging of complex biological specimens such as viral particles, cellular sections, and in some cases, whole cells. This enables the structural characterization of molecules in their near-native environments, without the need for purification or separation, thereby preserving biological information such as conformational states and spatial relationships between different molecular species. Subtomogram averaging is an image processing workflow that allows users to leverage cryo-ET data to identify and localize target molecules, determine high-resolution structures of repeating molecular species, and classifying different conformational states. Here we describe STOPGAP, an open-source package for subtomogram averaging designed to provide users with fine control over each of these steps. In providing detailed descriptions of the image processing algorithms that STOPGAP uses, we intend for this manuscript to also serve as a technical resource to users as well as further community-driven software development.

molecular biology↗

Deep reconstructing generative networks for visualizing dynamic biomolecules inside cells

Advances in cryo-electron tomography (cryo-ET) have produced new opportunities to visualize the structures of dynamic macromolecular machinery in native cellular environments. Here, we describe a machine learning approach that can reconstruct the structural landscape and dynamics of biomolecular complexes present in cryo-ET subtomograms. This method, cryoDRGN-ET, learns a deep generative model of 3D density maps directly from subtomogram tilt series images and can capture states diverse in both composition and conformation. We use this approach to reconstruct the in situ translation dynamics of prokaryotic ribosomes, and we reveal the distribution of functional states during translation elongation populated by S. cerevisiae ribosomes inside cells.

biophysics↗

Optimizing Cryo-FIB Lamellas for sub-5 Angstrom in situ Structural Biology

We here present a method based on metallic platinum sputtering that can substantially enhance the quality of subtomogram averages from lamellas and thereby reduce the number of particles needed for high-resolution subtomogram averaging. We provide evidence for the physical background of this improvement and demonstrate its usefulness by producing sub-5[A] ribosome averages from yeast.

molecular biology↗

Multishot Tomography for High-Resolution In Situ Subtomogram Averaging.

Cryo-electron tomography (cryo-ET) and subtomogram averaging (STA) can resolve protein complexes at near atomic resolution, and when combined with focused ion beam (FIB) milling, macromolecules can be observed within their native context. Unlike single particle acquisition (SPA), cryo-ET can be slow, which may reduce overall project throughput. We here propose a fast, multi-position tomographic acquisition scheme based on beam-tilt corrected beam-shift imaging along the tilt axis, which yields sub-nanometer in situ STA averages.

molecular biology↗