Search bioRxiv⌕ Search

Biology subjects

Kentch, K. P.

Publications and source records attributed to Kentch, K. P..

2 recordsLinked to original sources

Obesity-Associated Alterations In Lung Function In Mice Measured With Head-Out Plethysmography

Declines in lung function worsen quality of life and increase the risk of mortality. Obesity and non-alcoholic fatty liver disease are associated with worsened lung function. To investigate this association, we assessed lung function in lean and diet-induced obese conscious mice using our newly developed leak-free head-out plethysmography system. Obesity was associated with increased volume (P<0.0001), minute ventilation (volume per minute; P<0.0001), mid-expiratory flow (flow rate at 50% expiratory volume; P<0.0001), end-inspiratory pause (pause at end of inspiration; P<0.0001) and decreased expiratory time (P<0.0001). We next compared the response to methacholine (0, 25, 50, 100 mg/ml in PBS flow 0.2ml/30sec) measured using our head-out plethysmography system with forced oscillation technique (using the standard flexiVent system) measures taken in the same mice. Many of the measures gathered using head-out plethysmography were associated with measures collected using the forced oscillation technique. Minute ventilation was most significantly associated with maximal airway resistance, maximal airway elastance, tissue damping, and tissue elastance (r=-0.59 P<0.0001; r=-0.54 P<0.005; r=-0.48 P<0.005; r=-0.40 P<0.005 respectively). Volume, corrected for energy expenditure, was most significantly associated with maximal resistance of the conducting airways (r=-0.57 P<0.0001). Although fatty liver is associated with changes in lung function, we found neither hepatic vagotomy nor knocking down obesity-induced hepatic GABA production improved lung function in obese mice. Still, our head-out plethysmography system is ideal for assessing the response to interventions aimed at improving obesity-associated declines in lung function.

physiology↗

A Leak-Free Head-Out Plethysmography System to Accurately Assess Lung Function in Mice

Mice are a valuable model for elegant studies of complex, systems-dependent diseases, including pulmonary diseases. Current tools to assess lung function in mice are either terminal or lack accuracy. We set out to develop a low-cost, accurate, head-out variable-pressure plethysmography system to allow for repeated, non-terminal measurements of lung function in mice. Current head-out plethysmography systems are limited by air leaks that prevent accurate measures of volume and flow. We designed an inflatable cuff that encompasses the mouses neck preventing air leak. We wrote corresponding software to collect and analyze the data, remove movement artifacts, and automatically calibrate each dataset. This software calculates inspiratory/expiratory volume, inspiratory/expiratory time, breaths per minute, enhanced pause, mid-expiratory flow, and end-inspiratory pause. To validate the use, we established our plethysmography system accurately measured tidal breathing, the bronchoconstrictive response to methacholine, sex and age associated changes in breathing, and breathing changes associated with house dust mite sensitization. Our estimates of volume, flow, and timing of breaths are in line with published estimates, we observed dose-dependent decreases in volume and flow in response to methacholine (P < 0.05), increased lung volume and decreased breathing rate with aging (P < 0.05), and that house dust mite sensitization decreased tidal volume and flow (P <0.05) while exacerbating the methacholine induced increases in inspiratory and expiratory time (P < 0.05). We describe an accurate, sensitive, low-cost, head-out plethysmography system that allows for longitudinal studies of pulmonary disease in mice. New & NoteworthyWe describe a variable-pressure head-out plethysmography system that can be used to assess lung function in mice. A balloon cuff that inflates around the mouses neck prevents air leak, allowing for accurate measurements of lung volume and air flow. Custom software facilitates system calibration, removes movement artifacts, and eases data analysis. The system was validated by measuring tidal breathing, responses to methacholine, and changes associated with house dust mite sensitization, sex, and aging. Contributions to StudyO_LIStephanie Bruggink: development of head-out plethysmography chamber, measurement of breathing, data analysis, prepared manuscript C_LIO_LIKyle Kentch: development of head-out plethysmography chamber, programmed software to collect and analyze data, prepared manuscript C_LIO_LIJason Kronenfeld: development of tools to analyze data, analysis of data C_LIO_LIBenjamin Renquist: development of head-out plethysmography chamber, statistical analysis, prepared manuscript C_LI

physiology↗