Search bioRxiv⌕ Search

Biology subjects

Kanngiesser, S.

Publications and source records attributed to Kanngiesser, S..

2 recordsLinked to original sources

Reprograming of the ubiquitin ligase Ubr1 by intrinsically disordered Roq1 through cooperating multifunctional motifs

One way cells control the speed and specificity of protein degradation is by regulating the activity of ubiquitin ligases. Upon proteotoxic stress in yeast, the intrinsically disordered protein Roq1 binds the ubiquitin ligase Ubr1 as a pseudosubstrate, thereby modulating the degradation of substrates of the N-degron pathway and promoting the elimination of misfolded proteins. The mechanism underlying this reprograming of Ubr1 is unknown. Here, we show that Roq1 controls Ubr1 by means of two cooperating multifunctional motifs. The N-terminal arginine and a short hydrophobic motif of Roq1 interact with Ubr1 as part of a heterobivalent binding mechanism. Via its N-terminal arginine, Roq1 regulates the ubiquitination of various N-degron substrates and folded proteins. Via its hydrophobic motif, Roq1 accelerates the ubiquitination of misfolded proteins. These findings reveal how a small, intrinsically disordered protein with a simple architecture engages parallel channels of communication to reprogram a functionally complex ubiquitin ligase.

biochemistry↗

Parallelized Acquisition of Orbitrap and Astral Analyzers Enables High-Throughput Quantitative Analysis.

The growing trend towards high-throughput proteomics demands rapid liquid chromatography-mass spectrometry (LC-MS) cycles that limit the available time to gather the large numbers of MS/MS fragmentation spectra required for identification. Orbitrap analyzers scale performance with acquisition time, and necessarily sacrifice sensitivity and resolving power to deliver higher acquisition rates. We developed a new mass spectrometer that combines a mass resolving quadrupole, the Orbitrap and the novel Asymmetric Track Lossless (Astral) analyzer. The new hybrid instrument enables faster acquisition of high-resolution accurate mass (HRAM) MS/MS spectra compared to state-of-the-art mass spectrometers. Accordingly, new proteomics methods were developed that leverage the strengths of each HRAM analyzer, whereby the Orbitrap analyzer performs full scans with high dynamic range and resolution, synchronized with Astral analyzers acquisition of fast and sensitive HRAM MS/MS scans. Substantial improvements are demonstrated over previous methods using current state-of-the-art mass spectrometers. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=100 SRC="FIGDIR/small/543408v1_ufig1.gif" ALT="Figure 1"> View larger version (35K): org.highwire.dtl.DTLVardef@1eedfdeorg.highwire.dtl.DTLVardef@1ab7939org.highwire.dtl.DTLVardef@a3b2f8org.highwire.dtl.DTLVardef@13ac46b_HPS_FORMAT_FIGEXP M_FIG C_FIG

cell biology↗