Search bioRxiv⌕ Search

Biology subjects

Kajimoto, K.

Publications and source records attributed to Kajimoto, K..

3 recordsLinked to original sources

Kinetic modeling of continuous meta-fermentation quantifies metabolic activity in a complex microbial system

One of the serious drawbacks of a complex microbial system is the difficulty in quantifying the metabolic activity of each microorganism. A kinetic model of predominant microbial species was constructed for continuous meta-fermentation in a complex microbial system at several dilution rates (D). The introduction of biomass and lactic acid inhibition terms improved model accuracies at D = 0.05 h-1 and 0.4 h-1, respectively. The coefficient of determination (R2) and root mean square error (RMSE) improved from 0.577 and 5.21 to 0.972 and 0.759, respectively, with the inhibition term at D = 0.05 h-1. The inhibition terms resulted in good R{superscript 2} (0.996) and RMSE (1.27) values at D = 0.4 h-1. By solving the Michaelis-Menten equation in the constructed models, the species flux (SF) was calculated to estimate the metabolic activity (formation and consumption) of each microorganism. At D = 0.05 h-1, Caldibacillus hisashii contributed to lactic acid production at 0.333 g/L/h, whereas Clostridium cochlearium consumed lactic acid at 0.203 g/L/h, suggesting cross-feeding of a metabolite. It is therefore possible to account for consumption that cannot be considered in gene-derived calculations, indicating that this is a promising analytical method for investigating the dynamic behavior of complex microbial systems. Kinetic models for continuous meta-fermentation at several D values were developed. A new metabolic analysis method is proposed to estimate the activity of microbial species in a complex microbial system.

bioinformatics↗

Tongue-Palate Electromyographic Synchronization Related to Swallowing, Mastication, and Speech

The specific oscillatory dynamics of intermuscular coupling involved in swallowing, mastication, speech production, and respiration have not been elucidated. This study aimed to explore intermuscular coupling between the tongue and palate that underlies oral functions by analyzing the event-related coherence (ERC) of electromyography (EMG) signals before swallowing, mastication, and speech production. Twenty-two healthy participants performed three oral tasks: swallowing, speech production, and mastication. Sixteen of these participants also completed a combined task involving swallowing immediately after speech. EMG signals were recorded from the tongue and palate, and ERC between tongue and palate EMG was analyzed. Peak ERC was compared across tasks for alpha (8-14 Hz), beta (16-30 Hz), and gamma (32-46 Hz) frequency bands. In all participants, ERC showed significant peaks in all frequency bands before the onset of swallowing, mastication, and speech. Only the ERC values in the beta band were significantly larger for swallowing than for mastication, but not for speech. Moreover, the ERC values for the combined task of swallowing after speech production were significantly smaller than those for the simple swallowing task in the alpha, beta, and gamma bands. The intermuscular oscillatory regulation is more critical for swallowing than for mastication.

neuroscience↗

Field evaluation of a quantitative, and rapid malaria diagnostic system using a fluorescent Blue-ray optical device

We improved a previously developed quantitative malaria diagnostic system based on fluorescent Blue-ray optical device. Here, we first improved the diagnostic system to enable fully automated operation and the field application was evaluated in Kenya. We detected Plasmodium falciparum in blood samples collected from 288 individuals aged 1-16 years using nested polymerase chain reaction (nPCR), rapid diagnostic test (RDT), and automated system. Compared to RDT, the automated system exhibited a higher sensitivity (100%; 95% confidence interval [CI], 93.3-100%) and specificity (92.8%; 95%CI, 88.5-95.8%). The limit of detection was 0.0061%. Linear regression analysis revealed a correlation between the automated system and microscopic examination for detecting parasitemia (adjusted R2 value=0.63, P=1.13x10-12). The automated system exhibited a stable quantification of parasitemia and a higher diagnostic accuracy for parasitemia than RDT. This indicates the potential of this system as a valid alternative to conventional methods used at local health facilities, which lack basic infrastructure.

physiology↗