Search bioRxiv⌕ Search

Biology subjects

Kainerstorfer, J. M.

Publications and source records attributed to Kainerstorfer, J. M..

4 recordsLinked to original sources

Linking reaction time variability to physiological markers of arousal across timescales

Reaction time is a measure of the speed of our response to stimuli in the environment. Even for a well-trained task, a subjects reaction time varies. One source of this variability is internal state fluctuations (such as changes in arousal). There are few studies that systematically quantify the extent to which reaction time varies across different timescales and link this to measures of systemic physiology associated with arousal. In much of the literature, it is assumed but not demonstrated that behavioral and systemic measurements associated with arousal will be consistently linked because both estimate a common underlying arousal process. In this work, we examined this assumption by simultaneously measuring reaction time, heart rate, and pupil diameter in rhesus macaque monkeys performing several visual tasks over hours and across hundreds of sessions. We found a portion of the variability in reaction time could be linked to systemic physiological signatures of arousal on fast timescales from second to second and slower timescales from minute to minute. This link between reaction time and systemic physiology was also present for different biomarkers of arousal (heart rate and pupil). However, the strength of this relationship varied depending on the arousal biomarker. Our findings support the conclusion that there are multiple arousal mechanisms that act simultaneously to influence behavior and multiple timescales at which they operate.

neuroscience↗

From Breath to Behavior: Respiratory Features Predict Visual Detection Performance

Breathing is a continuous bodily rhythm that not only sustains physiology but also shapes brain function and behavior. Here we investigated how respiration interacts with perceptual performance in nonhuman primates performing a visual detection task. Using continuous recordings, we extracted detailed features from each respiratory cycle including timing, duration, phase, depth, and volume, aligned to trial onset. Analyses revealed that timing-related features, such as inhalation onset and the respiration length, were the most reliable markers of trial outcome, whereas amplitude-based measures contributed less consistently. These findings demonstrate that the temporal structure of breathing, rather than its magnitude, plays a dominant role in shaping behavior on a moment-to-moment basis. By uncovering how fine-grained features of respiration align with perceptual success, our work highlights respiration as a strong correlate of cognition and highlights the value of feature-based approaches for linking interoceptive rhythms to behavior.

animal behavior and cognition↗

Interaural time and level differences contribute differently to source segregation and spatial selection

Interaural time and level differences are crucial in sound localization, yet their contributions to sound source segregation and spatial selection remain underspecified. Here, participants completed a spatial auditory selective attention task while we measured hemodynamic activity in the prefrontal cortex and superior temporal gyrus using functional near-infrared spectroscopy. Participants listened to a target sound stream and a simultaneous spatially separated speech stream or white noise masker. Sound streams were spatialized with either 50 s interaural time differences (ITDs), 500 s ITDs, naturally occurring interaural level differences (ILDs) from a non-individualized head-related transfer function (HRTF), or broadband 10 dB ILDs. Behavioral results revealed a stronger effect of spatial cues when the masker was speech. Error patterns differed in the two difficult conditions, small ITDs and natural ILDs: Small ITDs produced lower hit rates, while naturally occurring ILDs produced higher false alarm rates. Small ITDs led to greater activity in prefrontal cortex and activity in superior temporal gyrus that was lateralized, greater in the hemisphere contralateral to attentional focus, consistent with previous reports. These results suggest that natural ILDs alone support source segregation even if they are insufficient to cause large shifts in perceived lateralization, explaining high false alarm rates (confusions between target and distractor words). In contrast, small ITDs alone may be insufficient to segregate competing sources, leading to low hit and false alarm rates. Together, these results reveal differences in how ITDs and ILDs contribute to auditory scene analysis and spatial attention.

neuroscience↗

Magnified interaural level differences enhance spatial release from masking in bilateral cochlear implant users

Bilateral cochlear implant (BiCI) usage makes binaural benefits a possibility for implant users. Yet for BiCI users, limited access to interaural time difference (ITD) cues and reduced saliency of interaural level difference (ILD) cues restricts perceptual benefits of spatially separating a target from masker sounds. The present study explored whether magnifying ILD cues improves intelligibility of masked speech for BiCI listeners in a "symmetrical-masker" configuration, which ensures that neither ear benefits from a long-term positive target-to-masker ratio (TMR) due to naturally occurring ILD cues. ILD magnification estimates moment-to-moment ITDs in octave-wide frequency bands, and applies corresponding ILDs to the target-masker mixtures reaching the two ears at each specific time and frequency band. ILD magnification significantly improved intelligibility in two experiments: one with NH listeners using vocoded stimuli and one with BiCI users. BiCI listeners showed no benefit of spatial separation between target and maskers with natural ILDs, even for the largest target-masker separation. Because ILD magnification relies on and manipulates only the mixed signals at each ear, the strategy never alters the monaural TMR in either ear at any time. Thus, the observed improvements to masked speech intelligibility come from binaural effects, likely from increased perceptual separation of the competing sources.

neuroscience↗