Search bioRxiv⌕ Search

Biology subjects

Johnson-Mackinnon, J.

Publications and source records attributed to Johnson-Mackinnon, J..

3 recordsLinked to original sources

A laboratory framework for ongoing optimisation of amplification based genomic surveillance programs

Constantly evolving viral populations affect the specificity of primers and quality of genomic surveillance. This study presents a framework for continuous optimisation of sequencing efficiency for public health surveillance based on the ongoing evolution of the COVID-19 pandemic. SARS-CoV-2 genomic clustering capacity based on three amplification based whole genome sequencing schemes was assessed using decreasing thresholds of genome coverage and measured against epidemiologically linked cases. Overall genome coverage depth and individual amplicon depth were used to calculate an amplification efficiency metric. Significant loss of genome coverage over time was documented which was recovered by optimisation of primer pooling or implementation of new primer sets. A minimum of 95% genome coverage was required to cluster 94% of epidemiologically defined SARS-CoV-2 transmission events. Clustering resolution fell to 70% when only 85% of genome coverage was achieved. The framework presented in this study can provide public health genomic surveillance programs a systematic process to ensure an agile and effective laboratory response during rapidly evolving viral outbreaks.

genomics↗

Improved neutralization of the SARS-CoV-2 Omicron variant after Pfizer-BioNTech BNT162b2 COVID-19 vaccine boosting

In late November 2021, the World Health Organization declared the SARS-CoV-2 lineage B.1.1.529 the fifth variant of concern, Omicron. This variant has acquired 15 mutations in the receptor binding domain of the spike protein, raising concerns that Omicron could evade naturally acquired and vaccine-derived immunity. We utilized an authentic virus, multicycle neutralisation assay to demonstrate that sera collected one, three and six months post-two doses of Pfizer-BioNTech BNT162b2 has a limited ability to neutralise SARS-CoV-2. However, four weeks after a third dose, neutralising antibody titres are boosted. Despite this increase, neutralising antibody titres are reduced four-fold for Omicron compared to lineage A.2.2 SARS-CoV-2.

microbiology↗

SARS-CoV-2 Genome Sequencing Methods Differ In Their Ability To Detect Variants From Low Viral Load Samples

SARS-CoV-2 genomic surveillance has been vital in understanding the spread of COVID-19, the emergence of viral escape mutants and variants of concern. However, low viral loads in clinical specimens affect variant calling for phylogenetic analyses and detection of low frequency variants, important in uncovering infection transmission chains. We systematically evaluated three widely adopted SARS-CoV-2 whole genome sequencing methods for their sensitivity, specificity, and ability to reliably detect low frequency variants. Our analyses highlight that the ARTIC v3 protocol consistently displays high sensitivity for generating complete genomes at low viral loads compared with the probe-based Illumina respiratory viral oligo panel, and a pooled long-amplicon method. We show substantial variability in the number and location of low-frequency variants detected using the three methods, highlighting the importance of selecting appropriate methods to obtain high quality sequence data from low viral load samples for public health and genomic surveillance purposes.

microbiology↗