Search bioRxiv⌕ Search

Biology subjects

Jenz, S. T.

Publications and source records attributed to Jenz, S. T..

3 recordsLinked to original sources

Motor unit discharge properties are modestly influenced by menstrual cycle-related fluctuations in sex hormone concentrations

Concentrations of estradiol (E2) and progesterone (P4), the main female sex hormones, exhibit large fluctuations across the menstrual cycle. Due to their receptors throughout the central nervous system, both hormones have the potential to influence motor function by influencing ionotropic and metabotropic inputs to motor pools, which can be estimated through the neural codes extracted from motor unit discharge patterns. To address key methodological limitations in prior menstrual cycle research on motor output, we established the Motor Units and Sex Hormones (MUSH) collaboration. The objective of this multi-site investigation was to determine whether endogenous fluctuations in estradiol and progesterone influence human motor unit activity. We hypothesized that motor unit discharge rates and persistent inward current (PIC)-related contributions to discharge would be greatest during the late follicular phase, when estradiol concentrations were highest. Fifty females completed a comprehensive protocol involving menstrual cycle and ovulation tracking, serum hormone measurement, and high-density surface electromyographic recordings during isometric contractions to quantify motor unit activity in the early follicular, late follicular, and mid luteal phases. After exclusion of 10 females with either atypical hormone concentration profiles or insufficient motor unit yield, 40 remained in the final analysis. There were significant changes in several motor unit discharge variables between menstrual cycle phases and significant associations with hormone concentrations. Increased estradiol was associated with higher peak discharge rates and ascending discharge rate nonlinearity, while increased progesterone was associated with higher peak discharge rates, more discharge rate hysteresis and ascending discharge rate nonlinearity. Despite reaching statistical significance, the magnitudes of these effects (i.e., effect sizes) were small. Overall, these findings indicate that fluctuations in sex hormones influence motor unit behavior, but the effects are subtle, highlighting the need for well-powered and methodologically rigorous menstrual cycle research. Graphical Abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=151 SRC="FIGDIR/small/699975v1_ufig1.gif" ALT="Figure 1"> View larger version (33K): org.highwire.dtl.DTLVardef@2eb2c0org.highwire.dtl.DTLVardef@1d98359org.highwire.dtl.DTLVardef@13e772borg.highwire.dtl.DTLVardef@1bb27_HPS_FORMAT_FIGEXP M_FIG C_FIG KEY POINTSO_LIThere are small but detectable differences in motor unit discharge rates between menstrual cycle phases, which are predicted by within-participant fluctuations in estradiol and progesterone. C_LIO_LIDischarge rate patterns that provide estimates of neuromodulatory and inhibitory input suggest that estradiol and progesterone can influence spinal cord circuitry differently than has previously been documented in the brain, highlighting an understudied aspect of female neurophysiology. C_LIO_LIVariability in menstrual cycles and associate hormones makes large-scale, rigorous studies especially valuable in female neuromuscular research. C_LI

neuroscience↗

Voluntary co-contraction of ankle muscles alters motor unit discharge characteristics and reduces estimates of persistent inward currents

Motoneuronal persistent inward currents (PICs) are both facilitated by neuromodulatory inputs and highly sensitive to local inhibitory circuits (e.g., Ia reciprocal inhibition). Methods aimed to increase group Ia reciprocal inhibition from the antagonistic muscle have been successful in decreasing PICs, and the diffuse actions of neuromodulators released during activation of remote muscles have increased PICs. However, it remains unknown how motoneurons function in the presence of simultaneous excitatory and inhibitory commands. To probe this topic, we investigated motor unit (MU) discharge patterns and estimated PICs during voluntary co-contraction of ankle muscles, which simultaneously demands the contraction of agonist-antagonist pairs. Twenty young adults randomly performed triangular ramps (10s up and down) of both co-contraction (simultaneous dorsiflexion and plantarflexion) and isometric dorsiflexion to a peak of 30% of their maximum muscle activity from a maximal voluntary contraction. Motor unit spike trains were decomposed from high-density surface electromyography recorded over the tibialis anterior (TA) using blind source separation algorithms. Voluntary co-contraction altered motor unit discharge rate characteristics, decreasing estimates of PICs by 20% (4.47 pulses per second (pps) vs 5.57 pps during isometric dorsiflexion). These findings suggest that, during voluntary co-contraction, the inhibitory input from the antagonist muscle overcomes the additional excitatory and neuromodulatory drive that may occur due to the co-contraction of the antagonist muscle, which constrains PIC behavior. KEY POINTSVoluntary co-contraction is a unique motor behavior that concurrently provides increases in excitatory and inhibitory inputs to motoneurons. During co-contraction of agonist-antagonist pairs, agonist motor unit discharge characteristics are altered, consistent with reductions in persistent inward current magnitude. Reciprocal inhibition from the antagonist likely becomes proportional to the increase in neural drive to the agonist, dampening the magnitude of persistent inward currents.

physiology↗

The effects of biological sex on estimates of persistent inward currents in the human lower limb

Non-invasive recordings of motor unit (MU) spike trains help us understand how the nervous system controls movement and how it adapts to various physiological conditions. The majority of study participants in human and non-human animal physiology studies are male, and it is assumed mechanisms uncovered in these studies are shared between males and females. However, sex differences in neurological impairment and physical performance warrant the study of sex as a biological variable in human physiology and performance. To begin addressing this gap in the study of biophysical properties of human motoneurons, we quantified MU discharge rates and estimates of persistent inward current (PIC) magnitude in both sexes by quantifying {Delta}F. We decomposed MU spike trains from the tibialis anterior (TA), medial gastrocnemius (MG), and soleus (SOL) using high-density surface electromyography and blind source separation algorithms. Ten participants of each sex performed slow triangular (10s up and down) isometric contractions to a peak of 30% of their maximum voluntary contraction. We then used linear mixed effects models to determine if peak discharge rate and {Delta}F were predicted by the fixed effects of sex, muscle, and their interaction. Despite a lack of significant sex-differences in peak discharge rates across all muscles, {Delta}F was larger ({chi}2(1) = 6.26, p = 0.012) in females (4.73 {+/-} 0.242 pps) than males (3.81 {+/-} 0.240 pps). These findings suggest that neuromodulatory drive, inhibitory input, and/or biophysical properties of motoneurons differ between the sexes and may contribute to differences in MU discharge patterns. KEY POINTS- Sex differences in motor unit studies have been revealed with greater inclusion of female participants, however, mechanisms for these differences remain unclear. - Estimates of persistent inward currents (i.e., {Delta}F) were greater in females than males in the tibialis anterior, medial gastrocnemius, and soleus muscles. - This suggests that neuromodulatory drive, monoaminergic signaling, or descending control may differ between the sexes. - Therefore, sex differences in estimates of PICs may provide a mechanism behind previously reported sex differences in motoneuron discharge patterns..

neuroscience↗