Search bioRxiv⌕ Search

Biology subjects

Jensen, W.

Publications and source records attributed to Jensen, W..

3 recordsLinked to original sources

Cell Type Weighted Dimensionality Reduction

High-dimensional single-cell technologies, such as flow cytometry and CITE-Seq, typically rely on established lineage markers to define cell identities. Additional markers are commonly analyzed within the context of these predefined cell types. Nonlinear projection methods such as t-SNE and UMAP provide a visual framework for this analysis by enabling the overlay of cell types and marker expression. However, these methods frequently produce projections where distinct cell types substantially overlap, hindering interpretation of marker expression patterns relative to known cell types. In this study, we investigate the underlying causes of this phenomenon and demonstrate that such overlaps often stem from the inherent high-dimensional structure of the data rather than limitations in the dimensionality reduction algorithms themselves. To address this, we introduce Cell Type Weighted Dimensionality Reduction (CWDR), a novel approach that incorporates lineage-based information through a supervised weighting mechanism. By integrating both cell identity and marker expression, CWDR preserves the visual separation between predefined cell types while maintaining the local variance necessary for downstream analysis. We validate our method across multiple high-dimensional flow cytometry and proteogenomic datasets. Our results show that CWDR significantly reduces inter-cluster overlap compared to traditional methods, providing a clearer framework for visualizing marker expression within the context of specific cell lineages.

bioinformatics↗

On the Reliability of Chronically Implanted Thin-Film Electrodes in Human Arm Nerves for Neuroprosthetic Applications

Direct stimulation of peripheral nerves can successfully provide sensory feedback to amputees while using hand prostheses. Recent clinical studies have addressed this important limitation of current prostheses solutions using different implantable electrode concepts. Longevity of the electrodes is key to success. We have improved the long-term stability of the polyimide-based transverse intrafascicular multichannel electrode (TIME) that showed promising performance in clinical trials by integration of silicon carbide adhesion layers. The TIMEs were implanted in the median and ulnar nerves of three trans-radial amputees for up to six months. Here, we present the characterization of the electrical properties of the thin-film metallization as well as material status post explantationem for the first time. The TIMEs showed reliable performance in terms of eliciting sensation and stayed within the electrochemical safe limits maintaining a good working range with respect to amplitude modulation. After termination of the trials and explantation of the probes, no signs of corrosion or morphological change to the thin-film metallization was observed by means of electrochemical and optical analysis. Damage to the metallization was assigned exclusively to mechanical impacts during explantation and handling. The results indicate that thin-film metallization on polymer substrates is applicable in permanent implant system.

bioengineering↗

Stability of Thin-Film Metallization in Flexible Stimulation Electrodes: Analysis and Improvement of in vivo Performance

Micro-fabricated neural interfaces based on polyimide (PI) are achieving increasing importance in translational research. The ability to produce well-defined micro-structures with properties that include chemical inertness, mechanical flexibility and low water uptake are key advantages for these devices. This paper reports the development of the transverse intrafascicular multichannel electrode (TIME) used to deliver intraneural sensory feedback to an upper-limb amputee in combination with a sensorized hand prosthesis. A first-in-human study limited to 30 days was performed. About 90 % of the stimulation contact sites of the TIMEs maintained electrical functionality and stability during the full implant period. However, optical analysis post-explantation revealed that 62.5 % of the stimulation contacts showed signs of mechanical damage at the metallization-PI interface. Such damage likely occurred due to handling during explantation and subsequent analysis, since a significant change in impedance was not observed in vivo. Nevertheless, whereas device integrity is mandatory for long-term functionality in chronic implantation, measures to increase the bonding strength of the metallization-PI interface deserve further investigation. We report here that silicon carbide (SiC) is an effective adhesion-promoting layer resisting heavy electrical stimulation conditions in vivo. Optical analysis of the new electrodes revealed that the metallization remained unaltered after delivering over 14 million pulses in vivo without signs of delamination at the metallization-PI interface. Reliable adhesion of thin-film metallization to substrate has been proven using SiC, improving the potential transfer of micro-fabricated neural electrodes for chronic clinical applications.

bioengineering↗