Search bioRxivSearch

Biology subjects

Jennifer McDaniel

Publications and source records attributed to Jennifer McDaniel.

4 recordsLinked to original sources

Genome-wide reconstruction of complex structural variants using read clouds

Recently developed methods that utilize partitioning of long genomic DNA fragments, and barcoding of shorter fragments derived from them, have succeeded in retaining long-range information in short sequencing reads. These so-called read cloud approaches represent a powerful, accurate, and cost-effective alternative to single-molecule long-read sequencing. We developed software, GROC-SVs, that takes advantage of read clouds for structural variant detection and assembly. We apply the method to two 10x Genomics data sets, one chromothriptic sarcoma with several spatially separated samples, and one breast cancer cell line, all Illumina-sequenced to high coverage. Comparison to short-fragment data from the same samples, and validation by mate-pair data from a subset of the sarcoma samples, demonstrate substantial improvement in specificity of breakpoint detection compared to short-fragment sequencing, at comparable sensitivity, and vice versa. The embedded longrange information also facilitates sequence assembly of a large fraction of the breakpoints; importantly, consecutive breakpoints that are closer than the average length of the input DNA molecules can be assembled together and their order and arrangement reconstructed, with some events exhibiting remarkable complexity. These features facilitated an analysis of the structural evolution of the sarcoma. In the chromothripsis, rearrangements occurred before copy number amplifications, and using the phylogenetic tree built from point mutation data we show that single nucleotide variants and structural variants are not correlated. We predict significant future advances in structural variant science using 10x data analyzed with GROC-SVs and other read cloud-specific methods.

Genomics

Evaluation of the External RNA Controls Consortium (ERCC) reference material using a modified Latin square design.

BACKGROUNDHighly multiplexed assays for quantitation of RNA transcripts are being used in many areas of biology and medicine. Using data generated by these transcriptomic assays requires measurement assurance with appropriate controls. Methods to prototype and evaluate multiple RNA controls were developed as part of the External RNA Controls Consortium (ERCC) assessment process. These approaches included a modified Latin square design to provide a broad dynamic range of relative abundance with known differences between four complex pools of ERCC RNA transcripts spiked into a human liver total RNA background.\n\nRESULTSERCC pools were analyzed on four different microarray platforms: Agilent 1- and 2-color, Illumina bead, and NIAID lab-made spotted microarrays; and two different second-generation sequencing platforms: the Life Technologies 5500xl and the Illumina HiSeq 2500. Individual ERCCs were assessed for reproducible performance in signal response to concentration among the platforms. Most demonstrated linear behavior if they were not located near one of the extremes of the dynamic range. Performance issues with any individual ERCC transcript could be attributed to detection limitations, platform-specific target probe issues, or potential mixing errors. Collectively, these pools of spike-in RNA controls were evaluated for suitability as surrogates for endogenous transcripts to interrogate the performance of the RNA measurement process of each platform. The controls were useful for establishing the dynamic range of the assay, as well as delineating the useable region of that range where differential expression measurements, expressed as ratios, would be expected to be accurate.\n\nCONCLUSIONSThe modified Latin square design presented here uses a composite testing scheme for the evaluation of multiple performance characteristics: linear performance of individual controls, signal response within dynamic range pools of controls, and ratio detection between pairs of dynamic range pools. This compact design provides an economical sample format for the evaluation of multiple external RNA controls within a single experiment per platform. These results indicate that well-designed pools of RNA controls, spiked-into samples, provide measurement assurance for endogenous gene expression experiments.

Genomics

Extensive sequencing of seven human genomes to characterize benchmark reference materials

The Genome in a Bottle Consortium, hosted by the National Institute of Standards and Technology (NIST) is creating reference materials and data for human genome sequencing, as well as methods for genome comparison and benchmarking. Here, we describe a large, diverse set of sequencing data for seven human genomes; five are current or candidate NIST Reference Materials. The pilot genome, NA12878, has been released as NIST RM 8398. We also describe data from two Personal Genome Project trios, one of Ashkenazim Jewish ancestry and one of Chinese ancestry. The data come from 12 technologies: BioNano Genomics, Complete Genomics paired-end and LFR, Ion Proton exome, Oxford Nanopore, Pacific Biosciences, SOLiD, 10X Genomics GemCode WGS, and Illumina exome and WGS paired-end, mate-pair, and synthetic long reads. Cell lines, DNA, and data from these individuals are publicly available. Therefore, we expect these data to be useful for revealing novel information about the human genome and improving sequencing technologies, SNP, indel, and structural variant calling, and de novo assembly.

Genomics

Using Mixtures of Biological Samples as Process Controls for RNA-sequencing experiments

BackgroundGenome-scale \"-omics\" measurements are challenging to benchmark due to the enormous variety of unique biological molecules involved. Mixtures of previously-characterized samples can be used to benchmark repeatability and reproducibility using component proportions as truth for the measurement. We describe and evaluate experiments characterizing the performance of RNA-sequencing (RNA-Seq) measurements, and discuss cases where mixtures can serve as effective process controls.\n\nResultsWe apply a linear model to total RNA mixture samples in RNA-seq experiments. This model provides a context for performance benchmarking. The parameters of the model fit to experimental results can be evaluated to assess bias and variability of the measurement of a mixture. A linear model describes the behavior of mixture expression measures and provides a context for performance benchmarking. Residuals from fitting the model to experimental data can be used as a metric for evaluating the effect that an individual step in an experimental process has on the linear response function and precision of the underlying measurement while identifying signals affected by interference from other sources. Effective benchmarking requires well-defined mixtures, which for RNA-Seq requires knowledge of the messenger RNA (mRNA) content of the individual total RNA components. We demonstrate and evaluate an experimental method suitable for use in genome-scale process control and lay out a method utilizing spike-in controls to determine mRNA content of total RNA in samples.\n\nConclusionsGenome-scale process controls can be derived from mixtures. These controls relate prior knowledge of individual components to a complex mixture, allowing assessment of measurement performance. The mRNA fraction accounts for differential enrichment of mRNA from varying total RNA samples. Spike-in controls can be utilized to measure this relationship between mRNA content and input total RNA. Our mixture analysis method also enables estimation of the proportions of an unknown mixture, even when component-specific markers are not previously known, whenever pure components are measured alongside the mixture.

Bioinformatics