Search bioRxiv⌕ Search

Biology subjects

Jang, K.-J.

Publications and source records attributed to Jang, K.-J..

4 recordsLinked to original sources

Long-Term Human Skin Platform for Modeling Chronic Inflammation, Environmental Stress, and Therapeutic Intervention

Chronic inflammation drives tissue dysfunction and aging, yet the dynamic interplay between persistent inflammatory signaling and structural deterioration remains difficult to study in human-relevant systems. Here, an advanced long-term human skin platform is presented that preserves native tissue architecture and epidermal, stromal, and immune-associated molecular programs for up to 4 weeks. Using this system, sustained cytokine-driven inflammation was modeled, demonstrating chronic inflammatory transcriptional programs, progressive histopathological changes, and persistent inflammatory mediator secretion that were broadly suppressed by the JAK inhibitor tofacitinib. Using aged donor tissue, prolonged senolytic-associated treatment attenuated inflammatory and remodeling pathways. Finally, UVB exposure triggered coordinated stress and inflammatory responses that were partially mitigated using topical sunscreen, demonstrating compatibility with environmental stress modeling and topical intervention within preserved tissue architecture. Together, these findings establish a versatile human skin platform for modeling chronic inflammation, aging-associated tissue remodeling, and environmental stress, providing a translational framework for investigating skin tissue dysfunction and evaluating therapeutic interventions.

bioengineering↗

Qualifying a human Liver-Chip for predictive toxicology: Performance assessment and economic implications

Human organ-on-a-chip (Organ-Chip) technology has the potential to disrupt preclinical drug discovery and improve success in drug development pipelines as it can recapitulate organ-level pathophysiology and clinical responses. The Innovation and Quality (IQ) consortium formed by multiple pharmaceutical and biotechnology companies to confront this challenge has published guidelines that define criteria for qualifying preclinical models, however, systematic and quantitative evaluation of the predictive value of Organ-Chips has not yet been reported. Here, 870 Liver-Chips were analyzed to determine their ability to predict drug-induced liver injury (DILI) caused by small molecules identified as benchmarks by the IQ consortium. The Liver-Chip met the qualification guidelines across a blinded set of 27 known hepatotoxic and non-toxic drugs with a sensitivity of 87% and a specificity of 100%. A computational economic value analysis suggests that with this performance the Liver-Chip could generate $3 billion annually for the pharmaceutical industry due to increased R&D productivity.

pharmacology and toxicology↗

Liver-Chip: Reproducing Human and Cross-Species Toxicities

Nonclinical rodent and non-rodent toxicity models used to support clinical trials of candidate drugs may produce discordant results or fail to predict complications in humans contributing to drug failures in the clinic. Here we applied microengineered Organ-on-Chip (Organ-Chip) technology to design rat, dog, and human Liver-Chips containing species-specific primary hepatocytes interfaced with liver sinusoidal endothelial cells, with or without Kupffer cells and hepatic stellate cells, cultured under physiological fluid flow. The Liver-Chips detected diverse phenotypes of liver toxicity including hepatocellular injury, steatosis, cholestasis, and fibrosis as well as species-specific toxicities when treated with tool compounds. Multi-species Liver-Chips may provide a useful platform for prediction of liver toxicity and inform human relevance of liver toxicities detected in animal studies to better determine safety and human risk.\n\nOne Sentence SummaryMicroengineered Organ-Chip technology has been used to design rat, dog and human Liver-Chips that recapitulate species-specific liver toxicities.

pharmacology and toxicology↗

A robotic platform for fluidically-linked human body-on-chips experimentation

Here we describe of an Interrogator instrument that uses liquid-handling robotics, a custom software package, and an integrated mobile microscope to enable automated culture, perfusion, medium addition, fluidic linking, sample collection, and in situ microscopic imaging of up to 10 Organ Chips inside a standard tissue culture incubator. The automated Interrogator platform maintained the viability and organ-specific functions of 8 different vascularized, 2-channel, Organ Chips (intestine, liver, kidney, heart, lung, skin, blood-brain barrier (BBB), and brain) for 3 weeks in culture when fluidically coupled through their endothelium-lined vascular channels using a common blood substitute medium. When an inulin tracer was perfused through the multi-organ Human Body-on-Chips (HuBoC) fluidic network, quantitative distributions of this tracer could be accurately predicted using a physiologically-based multi-compartmental reduced order (MCRO) in silico model of the experimental system derived from first principles. This automated culture platform enables non-invasive imaging of cells within human Organ Chips and repeated sampling of both the vascular and interstitial compartments without compromising fluidic coupling, which should facilitate future HuBoc studies and pharmacokinetics (PK) analysis in vitro.

bioengineering↗