Search bioRxiv⌕ Search

Biology subjects

Jain, A.

Publications and source records attributed to Jain, A..

203 records · Page 12Linked to original sources

Fast and Accurate Genomic Analyses using Genome Graphs

The human reference genome serves as the foundation for genomics by providing a scaffold for alignment of sequencing reads, but currently only reflects a single consensus haplotype, which impairs read alignment and downstream analysis accuracy. Reference genome structures incorporating known genetic variation have been shown to improve the accuracy of genomic analyses, but have so far remained computationally prohibitive for routine large-scale use. Here we present a graph genome implementation that enables read alignment across 2,800 diploid genomes encompassing 12.6 million SNPs and 4.0 million indels. Our Graph Genome Pipeline requires 6.5 hours to process a 30x coverage WGS sample on a system with 36 CPU cores compared with 11 hours required by the GATK Best Practices pipeline. Using complementary benchmarking experiments based on real and simulated data, we show that using a graph genome reference improves read mapping sensitivity and produces a 0.5% increase in variant calling recall, or about 20,000 additional variants being detected per sample, while variant calling specificity is unaffected. Structural variations (SVs) incorporated into a graph genome can be genotyped accurately under a unified framework. Finally, we show that iterative augmentation of graph genomes yields incremental gains in variant calling accuracy. Our implementation is a significant advance towards fulfilling the promise of graph genomes to radically enhance the scalability and accuracy of genomic analyses.

bioinformatics↗

Less is More: Oligomer extraction and hydrothermal annealing increase PDMS bonding forces for new microfluidics assembly and for biological studies

Key determinants in the emergence of complex cellular morphologies and functions are cues in the micro-environment. Primary among these is the presence of neighboring cells as networks form. Therefore, for high-resolution analysis, it is crucial to develop micro-environments that permit exquisite control of network formation. This is especially true in cell science, tissue engineering, and clinical biology. We introduce a new approach for assembling polydimethylsiloxane (PDMS)-based microfluidic environments that enhances cell network formation and analyses. We report that the combined processes of PDMS solvent-extraction (E-PDMS) and hydrothermal annealing create unique conditions that produce high-strength bonds between E-PDMS and glass - properties not associated with conventional PDMS. Extraction followed by hydrothermal annealing removes unbound oligomers, promotes polymer cross-linking, facilitates covalent bond formation with glass, and retains the highest biocompatibility. Our extraction protocol accelerates oligomer removal from 5 to 2 days. Resulting microfluidic platforms are uniquely suited for cell-network studies owing to high bond strengths, effectively corralling cellular extensions and eliminating harmful oligomers. We demonstrate simple, simultaneous actuation of multiple microfluidic domains for invoking ATP- and glutamate-induced Ca2+ signaling in glial-cell networks. These low-cost, simple E-PMDS modifications and flow manipulations further enable microfluidic technologies for cell-signaling and network studies as well as novel applications.

bioengineering↗

Stability of Commonly Used Haematological Parameters in Samples Stored at 33°C, 22°C and 4°C

AimThis study aimed to investigate the analytical bias and imprecision in haematological parameters induced by storage at 4{degrees}C, 22{degrees}C and 33 {degrees}C.\n\nMethodsThree K2EDTA anticoagulated vials of blood were collected from each of twenty blood donors and stored at 4{degrees}C, 22{degrees}C and 33{degrees}C respectively. Readings from each vial were taken at 0, 4, 6, 12, 24, 48 and 72 hours after collection on the Sysmex XP-100 analyser. The mean and median shift of the parameters relative to the baseline and the coefficient of variation for each time-temperature combination were calculated. The shift was compared to the maximum acceptable bias.\n\nResultsHaemoglobin, Red Blood Cell Count, White Blood Cell Count, Mean Corpuscular Haemoglobin were stable for at least twenty four hours at 33{degrees}C. Haematocrit, Mean Corpuscular Volume and Platelet Counts were stable for less than four hours at 33{degrees}C. All the above parameters were stable for longer at 22{degrees}C and 4{degrees}C. The three-part differential count showed instability within four hours at 33 {degrees}C.\n\nConclusionsStrict pre-analytical control is needed at 33{degrees}C or above due to the marked instability of most parameters. However, Haemoglobin, Red Blood Cell Count, White Blood Cell Count and Mean Corpuscular Haemoglobin remain relatively stable even at 33{degrees}C.\n\nKey MessageHaematology samples exposed to temperatures of 33{degrees}C or above show rapid change in MCV, HCT,MCHC, RDW, Platelet Counts and three-part differential counts. Settings where prolonged exposure to these temperatures cannot be avoided should rely on the more stable parameters of Haemoglobin, RBC Counts, MCH and WBC Counts.

pathology↗

Tracking electron uptake from a cathode into Shewanella cells: implications for generating maintenance energy from solid substrates.

While typically investigated as a microorganism capable of extracellular electron transfer to minerals or anodes, Shewanella oneidensis MR-1 can also facilitate electron flow from a cathode to terminal electron acceptors such as fumarate or oxygen, thereby providing a model systems for a process that has significant environmental and technological implications. This work demonstrates that cathodic electrons enter the electron transport chain of S. oneidensis when oxygen is used as the terminal electron acceptor. The effect of electron transport chain inhibitors suggested that a proton gradient is generated during cathode-oxidation, consistent with the higher cellular ATP levels measured in cathode-respiring cells relative to controls. Cathode oxidation also correlated with an increase in the cellular redox (NADH/FMNH2) pool using a bioluminescent assay. Using a proton uncoupler, generation of NADH/FMNH2 under cathodic conditions was linked to reverse electron flow mediated by the proton pumping NADH oxidase Complex I. A decrease in cathodic electron uptake was observed in various mutant strains including those lacking the extracellular electron transfer components necessary for anodic current generation. While no cell growth was observed under these conditions, here we show that cathode oxidation is linked to cellular energy conservation, resulting in a quantifiable reduction in cellular decay rate. This work highlights a potential mechanism for cell survival and/or persistence in environments where growth and division are severely limited.

microbiology↗

RNA Gelation in Repeat Expansion Disorders

Expansions of short nucleotide repeats in the protein coding and non-coding regions of >30 genes produce a variety of neurological and neuromuscular disorders including Huntingtons disease (CAG repeats), muscular dystrophy (CTG repeats) and amyotrophic lateral sclerosis (GGGGCC repeats) [1-3]. Expression of expanded repeats alone is sufficient to recapitulate disease pathology in animal models [4-6]. Repeat-containing transcripts accumulate in the nucleus as aberrant \"RNA foci\" [7-10] and sequester numerous RNA binding proteins [11,12], leading to a disruption of cellular homeostasis [13,14]. Interestingly, RNA foci, as well as the disease symptoms, only manifest at a critical threshold of nucleotide repeats: >30 for CAG/CTG expansions [1] and >7 for the GGGGCC expansion [15]. However, the reason for this characteristic threshold, as well as the molecular mechanism of foci formation, remain unresolved [16]. Here, we show that nucleotide repeat expansions in RNA create templates for multivalent Watson-Crick (CAG/CUG expansions) or Hoogsteen (GGGGCC expansion) base-pairing. These multivalent interactions cause purified RNAs containing repeat expansions to undergo a sol-gel transition and form micron-sized clusters. Reflecting an increase in the valency for intermolecular hybridization, the gelation of purified RNA only occurs above a critical number of trinucleotide or hexanucleotide repeats. These thresholds for in vitro RNA gelation are similar to those associated with manifestation of disease. By visualizing RNA in live cells, we show that nuclear foci form as a result of phase separation of the repeat-containing RNA and that these foci can be dissolved by agents that disrupt RNA gelation in vitro. Analogous to protein aggregation disorders, our results suggest that the sequence-specific gelation of RNAs could be a contributing factor to neurological disease.

biophysics↗