Rate-Dependent Mechanical Behavior of Human Femoropopliteal Arteries in Biaxial Testing

IntroductionArteries, like other soft tissues, exhibit viscoelastic mechanical behavior, meaning their response to stress and strain is time dependent. This implies that the way arteries deform depends not only on the amount of force applied but also on the rate at which the force is applied. This study investigates the effects of different loading rates on the mechanical behavior of human femoropopliteal arteries (FPAs) to understand their rate-dependent characteristics. MethodsHuman FPA specimens were collected from 14 donors, including 7 males and 7 females, aged 45-55 years. A 10x10 mm segment was isolated, mounted onto a biaxial testing device, and subjected to varying loading rates (10 to 50 mN/s). Mechanical responses were recorded, and stress-stretch curves were analyzed. Statistical analyses, including mixed-design ANOVA, assessed the impact of sex and loading rates on tissue stiffness. ResultsResults indicated significant loading-rate dependency, particularly in the circumferential direction. Stretch values decreased with increasing loading rates, more prominently in the circumferential than in the longitudinal direction (p-value<0.01). Statistical analyses revealed no significant interaction between sex and loading rate, though male arteries exhibited slightly higher compliance than female arteries. DiscussionThe findings demonstrate that the mechanical response of FPAs is highly dependent on the loading rate, with more pronounced effects observed in the circumferential direction. At higher loading rates, the human FPAs demonstrated a stiffer response in the circumferential direction. DedicationWe dedicate this work to the memory of our late student, Ali Zolfaghari Sichani, who passed away tragically during his doctoral studies. Ali performed the majority of the experiments and the initial analysis reported in this paper. His passion, dedication, and hard work were the foundation of this research, and he is deeply missed.

bioengineering↗

EXPERIMENTAL CHARACTERIZATION OF BALLOON ANGIOPLASTY IN HUMAN FEMOROPOPLITEAL ARTERIES WITH DIFFERENT CALCIUM BURDENS

IntroductionBalloon angioplasty is one of the most common treatments for Peripheral Artery Disease (PAD), but its clinical outcomes continue to disappoint, particularly when managing calcified lesions. We characterized luminal gains and damage after balloon angioplasty using high-resolution imaging, histology, and mechanical testing. MethodsFresh diseased human femoropopliteal arteries (FPA) from n=15 subjects (average age 69 {+/-} 9, range 53-90 years) with different calcium burdens were imaged before, during, and after angioplasty using micro-computed tomography, and luminal gains, calcium fractures, and resulting dissections were quantified. Histology was used to assess structural damage, and biaxial mechanical testing determined damage initiation stretches and stresses. ResultsIn severely calcified FPAs, calcification often manifested as rings or large plate-like deposits. When calcium spanned the entire circumference, angioplasty produced longitudinal cracks but [~]8% luminal area gain. In less calcified arteries, damage manifested primarily as tears along the internal elastic lamina and within the tunica media. Dissections were present in 53% of all FPAs after angioplasty, with a higher prevalence in more calcified vessels and vessels with stenosis (75% each). Damage initiated at lower biaxial stretches (1.11 {+/-} 0.02 vs 1.14-1.15) and lower longitudinal stresses (44 {+/-} 22 kPa vs 57 {+/-} 31 kPa) in severely calcified specimens compared with lightly calcified arteries, but larger calcium burdens generally required more circumferential stress to initiate damage (66 {+/-} 27 kPa). Diabetes mellitus was associated with a higher calcium burden. ConclusionsSevere calcification limits luminal gains after angioplasty. Less calcified arteries accumulate damage to the healthier wall while calcium remains mostly intact. These results may inform clinical strategies and the development of better devices to treat PAD.

bioengineering↗

NITINOL MATERIAL PROPERTIES OF 11 COMMERCIAL PERIPHERAL STENTS DETERMINED USING INVERSE COMPUTATIONAL ANALYSIS

Stent-artery interactions are influenced by the mechanical properties of self-expanding Nitinol stents, but data on these characteristics remain limited. Eleven stents (Absolute Pro, S.M.A.R.T. Control, Misago, Zilver, Complete SE, EverFlex, Innova, Pulsar-18, LifeStent, S.M.A.R.T. Flex, and Supera) used to treat peripheral arterial disease (PAD) were subjected to axial tension, compression, three-point bending, and torsion tests, and the data on reaction forces and moments were compared with finite element simulations of the same experiments. Inverse computational analysis was used to determine austenite and martensite elasticity, transformation stretch, stresses at the start and end of transformation loading, and the start of transformation stress in compression. Uniaxial tensile tests were done on isolated struts from Absolute Pro and Zilver stents to verify the results of the inverse analysis. Our study demonstrate that Nitinol material properties are significantly different across devices. Austenite elasticity ranged 7.5-85 GPa, martensite elasticity 10-47.8 GPa, transformation stretch 1.03-1.08, the start of transformation loading stress 386-465 MPa, the end of transformation loading stress 411-535 MPa, and the start of transformation stress in compression 150-900 MPa. Nitinol of S.M.A.R.T. Control and S.M.A.R.T. Flex devices had the softest response, while Pulsar-18 had the hardest. The presented Nitinol mechanical properties of commonly used PAD stents can improve the fidelity of computational models investigating stent-artery interactions and may help improve clinical outcomes of endovascular PAD repairs through better device design.