Trade-off between stimulation focality and the number of coils in multi-locus transcranial magnetic stimulation

ObjectiveCoils designed for transcranial magnetic stimulation (TMS) must incorporate trade-offs between the required electrical power or energy, focality and depth penetration of the induced electric field (E-field), coil size, and mechanical properties of the coil, as all of them cannot be optimally met at the same time. In multi-locus TMS (mTMS), a transducer consisting of several coils allows electronically targeted stimulation of the cortex without physically moving a coil. In this study, we aimed to investigate the relationship between the number of coils in an mTMS transducer, the focality of the induced E-field, and the extent of the cortical region within which the location and orientation of the maximum of the induced E-field can be controlled. ApproachWe applied convex optimization to design planar and spherically curved mTMS transducers of different E-field focalities and analyzed their properties. We characterized the trade-off between the focality of the induced E-field and the extent of the cortical region that can be stimulated with an mTMS transducer with a given number of coils. Main resultsAt the expense of the E-field focality, one can, with the same number of coils, design an mTMS transducer that can control the location and orientation of the peak of the induced E-field within a wider cortical region. SignificanceWith E-fields of moderate focality, the problem of electronically targeted TMS becomes considerably easier compared with highly focal E-fields; this may speed up the development of mTMS and the emergence of new clinical and research applications.

neuroscience↗

Probing the orientation specificity of excitatory and inhibitory circuitries in the primary motor cortex with multi-channel TMS

BackgroundThe electric field orientation is a crucial parameter for optimizing the excitation of neuronal tissue in transcranial magnetic stimulation (TMS). Yet, the effects of stimulus orientation on the short-interval intracortical inhibition (SICI) and intracortical facilitation (ICF) paradigms are poorly known, mainly due to significant technical challenges in manipulating the TMS-induced stimulus orientation within milliseconds. ObjectiveOur aim is to assess the effect of the TMS-induced stimulus orientation on the SICI and ICF paradigms and search for the optimal orientations to maximize the facilitation and suppression of the motor evoked potentials (MEP). MethodsWe applied paired-pulse multi-channel TMS in healthy subjects to generate SICI and ICF with conditioning and test pulses in the same, opposite, and perpendicular orientations to each other. The conditioning- and test-stimulus intensities were 80% and 110% of the resting motor threshold, respectively. ResultsBoth SICI and ICF were significantly affected by the conditioning- and test-stimulus orientation. MEP suppression and facilitation were strongest with both pulses delivered in the same direction. SICI with a 2.5-ms and ICF with a 6.0-ms interstimulus interval (ISI) were more sensitive to changes in stimulus orientation compared with SICI at 0.5- and ICF at 8.0-ms ISIs, respectively. ConclusionOur findings provide evidence that SICI and ICF at specific ISIs are mediated by distinct mechanisms. Such mechanisms exhibit a preferential orientation depending on the anatomical and morphological arrangement of inhibitory and excitatory neuronal populations. We also demonstrate that the SICI and ICF can be maximized by adjusting the TMS-induced electric field orientation.

neuroscience↗

Fine multi-coil electronic control of transcranial magnetic stimulation: effects of stimulus orientation and intensity

BackgroundTranscranial magnetic stimulation (TMS) coils allow only a slow, mechanical adjustment of the stimulating electric field (E-field) orientation in the cerebral tissue. Fast E-field control is needed to synchronize the stimulation with the ongoing brain activity. Also, empirical models that fully describe the relationship between evoked responses and the stimulus orientation and intensity are still missing. ObjectiveWe aimed to (1) develop a TMS transducer for manipulating the E-field orientation electronically with high accuracy at the neuronally meaningful millisecond-level time scale and (2) devise and validate a physiologically based model describing the orientation selectivity of neuronal excitability. MethodsWe designed and manufactured a two-coil TMS transducer. The coil windings were computed with a minimum-energy optimization procedure, and the transducer was controlled with our custom-made electronics. The electronic E-field control was verified with a TMS characterizer. The motor evoked potential amplitude and latency of a hand muscle were mapped in 3{degrees} steps of the stimulus orientation in 16 healthy subjects for three stimulation intensities. We fitted a logistic model to the motor response amplitude. ResultsThe two-coil TMS transducer allows one to manipulate the pulse orientation accurately without manual coil movement. The motor response amplitude followed a logistic function of the stimulus orientation; this dependency was strongly affected by the stimulus intensity. ConclusionThe developed electronic control of the E-field orientation allows exploring new stimulation paradigms and probing neuronal mechanisms. The presented model helps to disentangle the neuronal mechanisms of brain function and guide future non-invasive stimulation protocols.

neuroscience↗

The impact of artifact removal approaches on TMS-EEG signal

Transcranial magnetic stimulation (TMS)-evoked potentials (TEPs) allow one to assess cortical excitability and effective connectivity in clinical and basic research. However, obtaining clean TEPs is challenging due to the various TMS-related artifacts that contaminate the electroencephalographic (EEG) signal when the TMS pulse is delivered. Different preprocessing approaches have been employed to remove the artifacts, but the degree of artifact reduction or signal distortion introduced in this phase of analysis is still unknown. Knowing and controlling this potential source of uncertainty will increase the inter-rater reliability of TEPs and improve the comparability between TMS-EEG studies. The goal of this study was to assess the variability in TEP waveforms due to of the use of different preprocessing pipelines. To accomplish this aim, we preprocessed the same TMS-EEG data with four different pipelines and compared the results. The dataset was obtained from 16 subjects in two identical recording sessions, each session consisting of both left dorsolateral prefrontal cortex and left inferior parietal lobule stimulation at 100% of the resting motor threshold. Considerable differences in TEP amplitudes were found between the preprocessing pipelines. Topographies of TEPs from the different pipelines were all highly correlated ({rho}>0.8) at latencies over 100 ms. By contrast, waveforms at latencies under 100 ms showed a variable level of correlation, with {rho} ranging between 0.2 and 0.9. Moreover, the test-retest reliability of TEPs depended on the preprocessing pipeline. Taken together, these results take us to suggest that the choice of the preprocessing approach has a marked impact on the final TEP, and that caution should be taken when comparing TMS-EEG studies that used different approaches. Finally, we propose strategies to control this source of variability.

neuroscience↗

Hemodynamic changes in response to excitatory and inhibitory modulations by transcranial magnetic stimulation at the human sensorimotor cortex

Transcranial magnetic stimulation (TMS) can non-invasively induce both excitatory and inhibitory neuronal activity. However, the neurophysiological basis for both kinds of modulation remains elusive. In this study, with a controlled dosage over the 30-s interval, we elicited excitatory and inhibitory TMS modulations over the human primary motor cortex (M1) with TMS bursts of high (10-Hz and 30-Hz) and low frequency (0.5-Hz), respectively, and took functional magnetic resonance images (fMRI). Excitatory and inhibitory modulations were evidenced by changes in motor evoked potentials (MEP). Significantly increased fMRI signal at M1 was only detected under excitatory high-frequency TMS but not during inhibitory low-frequency TMS. The supplementary motor area (SMA) had significant fMRI signal changes after both excitatory and inhibitory TMS. The topology of the activated M1 and SMA matched the activated sensorimotor network during voluntary movement. The precuneus was selectively activated with bursts of five TMS pulses. These findings demonstrated the asymmetric hemodynamic responses to excitatory and inhibitory TMS modulations with region-dependent relationships between the local fMRI signal changes and TMS dosage over different time scales.

neuroscience↗

Automated search of stimulation targets with closed-loop transcranial magnetic stimulation

Transcranial magnetic stimulation (TMS) protocols often include a manual search of an optimal location and orientation of the coil or peak stimulating electric field to elicit motor responses in a target muscle. This target search is laborious, and the result is user-dependent. Here, we present a closed-loop search method that utilizes automatic electronic adjustment of the stimulation based on the previous responses. The electronic adjustment is achieved by multi-locus TMS, and the adaptive guiding of the stimulation is based on the principles of Bayesian optimization to minimize the number of stimuli (and time) needed in the search. We compared our target-search method with other methods, such as systematic sampling in a predefined cortical grid. Validation experiments on five healthy volunteers and further offline simulations showed that our adaptively guided search method needs only a relatively small number of stimuli to provide outcomes with good accuracy and precision. The automated method enables fast and user-independent optimization of stimulation parameters in research and clinical applications of TMS.Competing Interest StatementRJI is an advisor and a minority shareholder of Nexstim Plc. The other authors declare no competing interests.View Full Text

bioengineering↗

Individual head models for estimating the TMS-induced electric field in rat brain

In transcranial magnetic stimulation (TMS), the initial cortical activation due to stimulation is determined by the state of the brain and the magnitude, waveform, and direction of the induced electric field (E-field) in the cortex. The E-field distribution depends on the conductivity geometry of the head. The effects of deviations from a spherically symmetric conductivity profile have been studied in detail in humans. In small mammals, such as rats, these effects are more pronounced due to their smaller and less spherical heads. In this study, we describe a simple method for building individual realistically shaped head models for rats from high-resolution X-ray tomography images. We computed the TMS-induced E-field with the boundary element method and assessed the effect of head-model simplifications on the estimated E-field. The deviations from spherical symmetry have large, non-trivial effects on the E-field distribution: in some cases, even the direction of the E-field in the cortex cannot be reliably predicted by the coil orientation unless these deviations are properly considered.

neuroscience↗

Signal-space projection suppresses the tACS artifact in EEG recordings

1.BackgroundTo probe the functional role of brain oscillations, transcranial alternating current stimulation (tACS) has proven to be a useful neuroscientific tool. Because of the huge tACS-caused artifact in electroencephalography (EEG) signals, tACS-EEG studies have been mostly limited to compare brain activity between recordings before and after concurrent tACS. Critically, attempts to suppress the artifact in the data cannot assure that the entire artifact is removed while brain activity is preserved. The current study aims to evaluate the feasibility of specific artifact correction techniques to clean tACS-contaminated EEG data. New MethodIn the first experiment, we used a phantom head to have full control over the signal to be analyzed. Driving pre-recorded human brain-oscillation signals through a dipolar current source within the phantom, we simultaneously applied tACS and compared the performance of different artifact-correction techniques: sine subtraction, template subtraction, and signal-space projection (SSP). In the second experiment, we combined tACS and EEG on a human subject to validate the best-performing data-correction approach. ResultsThe tACS artifact was highly attenuated by SSP in the phantom and the human EEG; thus, we were able to recover the amplitude and phase of the oscillatory activity. In the human experiment, event-related desynchronization could be restored after correcting the artifact. Comparison with existing methodsThe best results were achieved with SSP, which outperformed sine subtraction and template subtraction. ConclusionsOur results demonstrate the feasibility of SSP by applying it to human tACS-EEG data.

neuroscience↗