Search bioRxiv⌕ Search

Biology subjects

Ianus, A.

Publications and source records attributed to Ianus, A..

8 recordsLinked to original sources

Non-invasive MRI of Blood-Cerebrospinal Fluid-Barrier Function: a Functional Biomarker of Early Alzheimer's Disease Pathology

INTRODUCTIONChoroid plexus (CP) dysfunction is thought to contribute to toxic protein build-up in neurodegenerative disorders, including Alzheimers disease (AD). However, the dynamics of this process remain unknown, mainly due to the paucity of in-vivo methods capable of assessing CP function. METHODSHere, we harness recent developments in Arterial Spin Labelling MRI to measure water delivery across the blood cerebrospinal fluid barrier (BCSFB) as a proxy for CP function, as well as cerebral blood flow (CBF), at different stages of AD progression in the widely used triple transgenic mouse model (3Tg), which recapitulates aspects of disease pathology. RESULTSTotal BCSFB-mediated water delivery is significantly higher in 3Tg mice (>50%) from 8 weeks (preclinical stage), while tissue parameters such as CBF and T1 are not different between groups at all ages. DISCUSSIONOur work shows changes in BCSFB function in the early stages of AD, providing a novel biomarker of pathology.

neuroscience↗

Efficient PCA denoising of spatially correlated MRI data

Mar[c]enko-Pastur (MP) PCA denoising is emerging as an effective means for noise suppression in MRI acquisitions with redundant dimensions. However, MP-PCA performance is severely compromised by spatially correlated noise - an issue typically affecting most modern MRI acquisitions - almost to the point of returning the original images with little or no noise removal. In this study, we develop and apply two new strategies that enable efficient and robust denoising even in the presence of severe spatial correlations. This is achieved by measuring a-priori information about the noise variance and combing these estimates with PCA denoising thresholding concepts. The two denoising strategies developed here are: 1) General PCA (GPCA) denoising that uses a-priori noise variance estimates without assuming specific noise distributions; and 2) Threshold PCA (TPCA) denoising which removes noise components with a threshold computed from a-priori estimated noise variance to determine the upper bound of the MP distribution. These strategies were tested in simulations with known ground truth and applied for denoising diffusion MRI data acquired using pre-clinical (16.4T) and clinical (3T) MRI scanners. In synthetic phantoms, MP-PCA failed to denoise spatially correlated data, while GPCA and TPCA correctly classified all signal/noise components. In cases where the noise variance was not accurately estimated (as can be the case in many practical scenarios), TPCA still provides excellent denoising performance. Our experiments in pre-clinical diffusion data with highly corrupted by spatial correlated noise revealed that both GPCA and TPCA robustly denoised the data while MP-PCA denoising failed. In in vivo diffusion MRI data acquired on a clinical scanner in healthy subjects, MP-PCA weakly removed noised, while TPCA was found to have the best performance, likely due to misestimations of the noise variance. Thus, our work shows that these novel denoising approaches can strongly benefit future pre-clinical and clinical MRI applications.

neuroscience↗

Optimisation and Pre-clinical Demonstration of Temporal Diffusion Ratio for Imaging Restricted Diffusion

Temporal Diffusion Ratio (TDR) is a recently proposed dMRI technique (DellAcqua, 2019) which provides contrast between areas with restricted diffusion and areas either without restricted diffusion or with length scales too small for characterisation. Hence, it has a potential for mapping pore sizes, in particular large axon diameters or other cellular structures. TDR employs the signal from two dMRI acquisitions obtained with the same, large, b-value but with different diffusion times and gradient settings. TDR is advantageous as it employs standard acquisition sequences, does not make any assumptions on the underlying tissue structure and does not require any model fitting, avoiding issues related to model degeneracy. This work for the first time optimises the TDR diffusion sequences in simulation for a range of different tissues and scanner constraints. We extend the original work (which considers substrates containing cylinders) by additionally considering the TDR signal obtained from spherical structures, representing cell soma in tissue. Our results show that contrasting an acquisition with short gradient duration and short diffusion time with an acquisition with long gradient duration and long diffusion time improves the TDR contrast for a wide range of pore configurations. Additionally, in the presence of Rician noise, computing TDR from a subset (50% or fewer) of the acquired diffusion gradients rather than the entire shell as proposed originally further improves the contrast. In the last part of the work the results are demonstrated experimentally on rat spinal cord. In line with simulations, the experimental data shows that optimised TDR improves the contrast compared to non-optimised TDR. Furthermore, we find a strong correlation between TDR and histology measurements of axon diameter. In conclusion, we find that TDR has great potential and is a very promising alternative (or potentially complement) to model-based approaches for mapping pore sizes and restricted diffusion in general. HighlightsO_LITemporal Diffusion Ratio (TDR) 2-seq approach maps areas with restricted diffusion C_LIO_LIOptimised gradient waveform pair is: long {delta} + low G and short {delta} + high G C_LIO_LIIf data is noisy calculating TDR using HARDI acquisition subsets increases accuracy C_LIO_LIWe demonstrate TDR for the first time pre-clinically in rat spinal cord C_LIO_LIPre-clinical TDR values are strongly correlated with axon diameter C_LI

bioengineering↗

In vivo Correlation Tensor MRI reveals microscopic kurtosis in the human brain on a clinical 3T scanner

Diffusion MRI (dMRI) has become one of the most important imaging modalities for noninvasively probing tissue microstructure. Diffusion Kurtosis MRI (DKI) quantifies the degree of non-gaussian diffusion, which in turn has been shown to increase sensitivity towards, e.g., disease and orientation mappings in neural tissue. However, the specificity of DKI is limited as different microstructural sources can contribute to the total diffusional kurtosis, including: variance in diffusion tensor magnitudes (Kiso), variance due to intravoxel diffusion anisotropy (Kaniso), and microscopic kurtosis (K) related to restricted diffusion and/or microstructural disorder. The latter in particular is typically ignored in diffusion MRI signal modeling as it is assumed to be negligible. Recently, Correlation Tensor MRI (CTI) based on Double-Diffusion-Encoding (DDE) was introduced for kurtosis source separation and revealed non negligible K in preclinical imaging. Here, we implemented CTI for the first time on a clinical 3T scanner and investigated the kurtosis sources in healthy subjects. A robust framework for kurtosis source separation in humans is introduced, followed by estimation of the relative importance of K in the healthy brain. Using this clinical CTI approach, we find that K significantly contributes to total diffusional kurtosis both in gray and white matter tissue but, as expected, not in the ventricles. The first K maps of the human brain are presented. We find that the spatial distribution of K provides a unique source of contrast, appearing different from isotropic and anisotropic kurtosis counterparts. We further show that ignoring K - as done by many contemporary methods based on multiple gaussian component approximation for kurtosis source estimation - biases the estimation of other kurtosis sources and, perhaps even worse, compromises their interpretation. Finally, a twofold acceleration of CTI is discussed in the context of potential future clinical applications. We conclude that CTI has much potential for future in vivo microstructural characterizations in healthy and pathological tissue. HighlightsO_LICorrelation Tensor MRI (CTI) was recently proposed to resolve kurtosis sources C_LIO_LIWe implemented CTI on a 3T scanner to study kurtosis sources in the human brain C_LIO_LIIsotropic, anisotropic, and microscopic kurtosis sources were successfully resolved C_LIO_LIMicroscopic kurtosis (K) significantly contributes to overall kurtosis in human brain C_LIO_LIK provides a novel source of contrast in the human brain in vivo C_LI

neuroscience↗

Soma and Neurite Density MRI (SANDI) of the in-vivo mouse brain

Diffusion MRI (dMRI) provides unique insights into the neural tissue milieu by probing interaction of diffusing molecules and tissue microstructure. Most dMRI techniques focus on white matter tissues (WM) due to the relatively simpler modelling of diffusion in the more organized tracts; however, interest is growing in gray matter characterisations. The Soma and Neurite Density MRI (SANDI) methodology harnesses a model incorporating water diffusion in spherical objects (assumed to be associated with cell bodies) and in impermeable "sticks" (representing neurites), which potentially enables the characterisation of cellular and neurite densities. Recognising the importance of rodents in animal models of development, aging, plasticity, and disease, we here sought to develop SANDI for preclinical imaging and provide a validation of the methodology by comparing its metrics with the Allen mouse brain atlas. SANDI was implemented on a 9.4T scanner equipped with a cryogenic coil, and experiments were carried out on N=6 mice. Pixelwise, ROI-based, and atlas comparisons were performed, and results were also compared to more standard Diffusion Kurtosis MRI (DKI) metrics. We further investigated effects of different pre-processing pipelines, specifically the comparison of magnitude and real-valued data, as well as different acceleration factors. Our findings reveal excellent reproducibility of the SANDI parameters, including the sphere and stick fraction as well as sphere size. More strikingly, we find a very good rank correlation between SANDI-driven soma fraction and Allen brain atlas contrast (which represents the cellular density in the mouse brain). Although some DKI parameters (FA, MD) correlated with some SANDI parameters in some ROIs, they did not correlate nearly as well as SANDI parameters with the Allen atlas, suggesting a much more specific nature of the SANDI parameters. We conclude that SANDI is a viable preclinical MRI technique that can greatly contribute to research on brain tissue microstructure.

neuroscience↗

On the generalizability of diffusion MRI signal representations across acquisition parameters, sequences and tissue types: chronicles of the MEMENTO challenge.

Diffusion MRI (dMRI) has become an invaluable tool to assess the microstructural organization of brain tissue. Depending on the specific acquisition settings, the dMRI signal encodes specific properties of the underlying diffusion process. In the last two decades, several signal representations have been proposed to fit the dMRI signal and decode such properties. Most methods, however, are tested and developed on a limited amount of data, and their applicability to other acquisition schemes remains unknown. With this work, we aimed to shed light on the generalizability of existing dMRI signal representations to different diffusion encoding parameters and brain tissue types. To this end, we organized a community challenge - named MEMENTO, making available the same datasets for fair comparisons across algorithms and techniques. We considered two state-of-the-art diffusion datasets, including single-diffusion-encoding (SDE) spin-echo data from a human brain with over 3820 unique diffusion weightings (the MASSIVE dataset), and double (oscillating) diffusion encoding data (DDE/DODE) of a mouse brain including over 2520 unique data points. A subset of the data sampled in 5 different voxels was openly distributed, and the challenge participants were asked to predict the remaining part of the data. After one year, eight participant teams submitted a total of 80 signal fits. For each submission, we evaluated the mean squared error, the variance of the prediction error and the Bayesian information criteria. Most predictions predicted either multi-shell SDE data (37%) or DODE data (22%), followed by cartesian SDE data (19%) and DDE (18%). Most submissions predicted the signals measured with SDE remarkably well, with the exception of low and very strong diffusion weightings. The prediction of DDE and DODE data seemed more challenging, likely because none of the submissions explicitly accounted for diffusion time and frequency. Next to the choice of the model, decisions on fit procedure and hyperparameters play a major role in the prediction performance, highlighting the importance of optimizing and reporting such choices. This work is a community effort to highlight strength and limitations of the field at representing dMRI acquired with trending encoding schemes, gaining insights into how different models generalize to different tissue types and fiber configurations over a large range of diffusion encodings.

neuroscience↗

"Select and retrieve via direct upsampling" network (SARDU-Net): a data-driven, model-free, deep learning approach for quantitative MRI protocol design

PurposeWe introduce "Select and retrieve via direct upsampling" network (SARDU-Net), a data-driven framework for model-free quantitative MRI (qMRI) protocol design, and demonstrate it on in vivo brain and prostate diffusion-relaxation imaging (DRI). MethodsSARDU-Net selects subsets of informative measurements within lengthy pilot scans, without the requirement to identify tissue parameters for which to optimise for. The algorithm consists of a selector, identifying measurement subsets, and a predictor, estimating fully-sampled signals from the subsets. We implement both using deep neural networks, which are trained jointly end-to-end. We demonstrate the algorithm on brain (32 diffusion-/T1-weightings) and prostate (16 diffusion-/T2-weightings) DRI scans acquired on 3 healthy volunteers on two separate 3T Philips systems each. We used SARDU-Net to identify sub-protocols of fixed size, assessing the reproducibility of the procedure and testing sub-protocols for their potential to inform multi-contrast analyses via T1-weighted spherical mean diffusion tensor (T1-SMDT, brain) and hybrid multi-dimensional MRI (HM-MRI, prostate) modelling. ResultsIn both brain and prostate, SARDU-Net identifies sub-protocols that maximise information content in a reproducible manner across training instantiations. The sub-protocols enable multi-contrast modelling for which they were not optimised explicitly, providing robust T1-SMDT and HM-MRI maps and goodness-of-fit in the top 5% against extensive sub-protocol comparisons. ConclusionsSARDU-Net gives new opportunities to identify economical but informative qMRI protocols from a subset of the pilot scans that can be used for acquisition-time-sensitive applications. The simple architecture makes the algorithm easy to train when exhaustive searches are intractable, and applicable to a variety of anatomical contexts.

bioengineering↗

Quantitation of brain tumour microstructure response to Temozolomide therapy using non-invasive VERDICT MRI

There has been slow progress in the development of new therapeutic strategies for treating brain tumours, partly because assessment of treatment response is difficult and largely reliant on simple bi-dimensional measurements of MRI contrast-enhancing regions. Hence, there is a clinical need to develop improved imaging techniques for monitoring treatment response. In this study, we evaluate VERDICT (Vascular, Extracellular and Restricted Diffusion for Cytometry in Tumors) MRI in mouse glioblastomas for the quantification of tumour microstructure and assessment of response to Temozolomide (TMZ) chemotherapy, and, we investigate the feasibility of applying VERDICT MRI in a range of human gliomas. VERDICT MRI detected response to TMZ earlier than structural and apparent diffusion coefficient (ADC) measurements. A significant reduction in the cell radius parameter was detected three days earlier than ADC and six days earlier than structural MRI. Histological analysis showed the same trend as VERDICT of decreased intracellular volume fraction in the TMZ-treated mice. Vascular volume fraction was not altered by TMZ, which was consistent with optical projection tomography measurements. In patients, glioblastoma compartmental volume fractions showed good agreement with mouse glioblastoma parameters. The VERDICT parameters varied across the human gliomas, with raised intracellular volume fraction in the oligodendrogliomas and elevated cell radius in both low-grade tumours subtypes. In conclusion, our results suggest that VERDICT MRI is more sensitive at detecting TMZ response than structural or ADC measurements. In patients, VERDICT is feasible within clinical scan times, and performed best at characterising glioblastoma. Further optimisation should improve assessment of different glioma subtypes.

biophysics↗