Search bioRxiv⌕ Search

Biology subjects

Hsu, C.-C. H.

Publications and source records attributed to Hsu, C.-C. H..

2 recordsLinked to original sources

Integrated Diffusion Image Operator (iDIO): A tool for automated configuration and processing of diffusion MRI data

The preprocessing of diffusion magnetic resonance imaging (dMRI) data involves numerous steps, including the corrections for head motion, susceptibility distortion, low signal-to-noise ratio, and signal drifting. Researchers or clinical practitioners often need to configure different preprocessing steps depending on disparate image acquisition schemes, which increases the technical threshold for dMRI analysis for non-expert users. This could cause disparities in data processing approaches and thus hinder the comparability between studies. To make the dMRI data processing steps transparent and adapt to various dMRI acquisition schemes for researchers, we propose a semi-automated pipeline tool for dMRI named integrated Diffusion Image Operator or iDIO. This pipeline integrates features from a wide range of advanced dMRI software tools and targets at providing a one-click solution for dMRI data analysis, via automatic configuration for a set of optimal processing steps based on the image header of the input data. Additionally, the pipeline provides options for post-processing, such as estimation of diffusion tensor metrics and whole-brain tractography-based connectomes reconstruction using common brain atlases. The iDIO pipeline also outputs an easy-to-interpret quality control report to facilitate users to assess the data quality. To keep the transparency of data processing, the execution log and all the intermediate images produced in the iDIOs workflow are accessible. The goal of iDIO is to reduce the barriers for clinical or non-specialist users to adopt the state-of-art dMRI processing steps.

neuroscience↗

Validating Pore Size Estimates in a Complex Microfibre Environment on a Human MRI System

PurposeRecent advances in diffusion-weighted MRI provide restricted diffusion signal fraction and restricting pore size estimates. Materials based on co-electrospun oriented hollow cylinders have been introduced to provide validation for such methods. This study extends this work, exploring accuracy and repeatability using an extended acquisition on a 300 mT/m gradient human MRI scanner, in substrates closely mimicking tissue, i.e., non-circular cross-sections, intra-voxel fibre crossing, intra-voxel distributions of pore-sizes and smaller pore-sizes overall. MethodsIn a single-blind experiment, diffusion-weighted data were collected from a biomimetic phantom on a 3T Connectom system using multiple gradient directions/diffusion times. Repeated scans established short-term and long-term repeatability. The total scan time (54 minutes) matched similar protocols used in human studies. The number of distinct fibre populations was estimated using spherical deconvolution, and median pore size estimated through the combination of CHARMED and AxCaliber3D framework. Diffusion-based estimates were compared with measurements derived from scanning electron microscopy. ResultsThe phantom contained substrates with different orientations, fibre configurations and pore size distributions. Irrespective of one or two populations within the voxel, the pore-size estimates (~5m) and orientation-estimates showed excellent agreement with the median values of pore-size derived from scanning electron microscope and phantom configuration. Measurement repeatability depended on substrate complexity, with lower values seen in samples containing crossing-fibres. Sample-level repeatability was found to be good. ConclusionWhile no phantom mimics tissue completely, this study takes a step closer to validating diffusion microstructure measurements for use in vivo by demonstrating the ability to quantify microgeometry in relatively complex configurations.

biophysics↗