Search bioRxivSearch

Biology subjects

Hoerning, O.

Publications and source records attributed to Hoerning, O..

2 recordsLinked to original sources

Online parallel accumulation - serial fragmentation (PASEF) with a novel trapped ion mobility mass spectrometer

In bottom-up proteomics, peptides are separated by liquid chromatography with elution peak widths in the range of seconds, while mass spectra are acquired in about 100 microseconds with time-of-fight (TOF) instruments. This allows adding ion mobility as a third dimension of separation. Among several formats, trapped ion mobility spectrometry (TIMS) is attractive due to its small size, low voltage requirements and high efficiency of ion utilization. We have recently demonstrated a scan mode termed parallel accumulation - serial fragmentation (PASEF), which multiplies the sequencing speed without any loss in sensitivity (Meier et al., PMID: 26538118). Here we introduce the timsTOF Pro instrument, which optimally implements online PASEF. It features an orthogonal ion path into the ion mobility device, limiting the amount of debris entering the instrument and making it very robust in daily operation. We investigate different precursor selection schemes for shotgun proteomics to optimally allocate in excess of 100 fragmentation events per second. More than 800,000 fragmentation spectra in standard 120 min LC runs are easily achievable, which can be used for near exhaustive precursor selection in complex mixtures or re-sequencing weak precursors. MaxQuant identified more than 6,400 proteins in single run HeLa analyses without matching to a library, and with high quantitative reproducibility (R > 0.97). Online PASEF achieves a remarkable sensitivity with more than 2,900 proteins identified in 30 min runs of only 10 ng HeLa digest. We also show that highly reproducible collisional cross sections can be acquired on a large scale (R > 0.99). PASEF on the timsTOF Pro is a valuable addition to the technological toolbox in proteomics, with a number of unique operating modes that are only beginning to be explored.

systems biology

A novel LC system embeds analytes in pre-formed gradients for rapid, ultra-robust proteomics

To further integrate mass spectrometry (MS)-based proteomics into biomedical research and especially into clinical settings, high throughput and robustness are essential requirements. They are largely met in high-flow rate chromatographic systems for small molecules but these are not sufficiently sensitive for proteomics applications. Here we describe a new concept that delivers on these requirements while maintaining the sensitivity of current nano-flow LC systems. Low-pressure pumps elute the sample from a disposable trap column, simultaneously forming a chromatographic gradient that is stored in a long storage loop. An auxiliary gradient creates an offset, ensuring the re-focusing of the peptides before the separation on the analytical column by a single high-pressure pump. This simplified design enables robust operation over thousands of sample injections. Furthermore, the steps between injections are performed in parallel, reducing overhead time to a few minutes and allowing analysis of more than 200 samples per day. From fractionated HeLa cell lysates, deep proteomes covering more than 130,000 sequence unique peptides and close to 10,000 proteins were rapidly acquired. Using this data as a library, we demonstrate quantitation of 5200 proteins in only 21 min. Thus, the new system-termed Evosep One-analyzes samples in an extremely robust and high throughput manner, without sacrificing in depth proteomics coverage.

biochemistry