Search bioRxiv⌕ Search

Biology subjects

Heye, J.

Publications and source records attributed to Heye, J..

6 recordsLinked to original sources

Particle-Only gECM Wafers Enable Cohesive, ECM-Rich Scaffolds Without Secondary Polymers

Granular extracellular matrix (gECM)-based biomaterials commonly contain polymer components to improve scaffold cohesion and handling during fabrication and use. However, these polymer hydrogel components may dilute ECM content and increase fabrication and regulatory complexity. This study evaluated whether particle-only gECM wafers could serve as a simplified alternative to hydrogel-based gECM scaffolds while maintaining structural, mechanical, and biological performance. Decellularized human cartilage and skin tissues were processed and fabricated into three scaffold formats: gECM hydrogels, freeze-dried gECM hydrogel wafers, and freeze-dried particle-only gECM wafers. Across fabrication methods, scaffold swelling, volume fraction, and stiffness were strongly influenced by both tissue type and fabrication approach. gECM hydrogels exhibited the greatest swelling and lowest stiffness, while gECM wafers displayed higher volume fractions and greater mechanical stiffness. Notably, gECM particle-only wafers achieved performance comparable to gECM hydrogel wafers despite the absence of a secondary polymer network. Particle-only wafers also maintained swelling behavior and structural properties over 3 months of dry storage at room temperature, with only modest decreases in stiffness. In vitro studies showed sustained cell viability over 14 days on particle-only wafers, with chondrocytes infiltrating cartilage wafers and fibroblasts remaining primarily surface-localized on skin wafers. In addition, particle-only wafers remained cohesive during implantation into a bovine cartilage defect model. These findings demonstrate that particle-only gECM wafers can achieve structural integrity, mechanical performance, and cytocompatibility without the need for an additional polymer network, highlighting a simplified and ECM-rich biomaterial platform. By eliminating polymer carriers and enabling dry storage with preserved function, this approach supports the development of off-the-shelf, translationally accessible gECM particle-only wafers for tissue engineering applications.

bioengineering↗

Human Osteochondral Granular Extracellular Matrix (gECM) Hydrogels Drive Tissue-Specific Composition and Mechanics

Osteochondral defects remain a major clinical challenge due to the limited regenerative capacity of cartilage and the complexity of the osteochondral interface. Here, we present a human-derived granular extracellular matrix (gECM) hydrogel platform designed for translational osteochondral repair. Using otherwise discarded human donor tissues, we developed cartilage and bone gECM hydrogels under current good manufacturing practice workflows. These materials are shear-thinning, immediately hold their form, and crosslink under physiological conditions to form stable constructs. Proteomic analysis confirmed that cartilage and bone gECM retain distinct tissue-specific biochemical signatures, while mechanical characterization demonstrated tissue-relevant stiffness, with bone gECM hydrogels exhibiting greater stiffness than cartilage gECM hydrogel. Particle packing density primarily governed viscosity, whereas tissue type contributed strongly to bulk stiffness. Together, these findings establish a scalable, human-derived gECM platform that integrates tissue-specific structural and mechanical cues, and advances a clinically translatable strategy for osteochondral repair.

bioengineering↗

Granular Extracellular Matrix (gECM) Hydrogel Wafers as Shelf-Stable 2.5D Substrates for Microphysiological Modeling

Understanding disease pathology and evaluating emerging therapeutics require in vitro models that accurately recapitulate human tissue environments. However, existing microphysiological systems often compromise either biomimicry or ease-of-use, limiting widespread adoption and scalability. Here, we present lyophilized granular extracellular matrix (gECM) hydrogel wafers as shelf-stable, humanized 2.5D substrates that enable physiologically relevant modeling while simplifying integration into experimental workflows. Derived from decellularized human cartilage and bone, gECM hydrogel wafers retain tissue-specific architecture while introducing microporosity and surface topography through lyophilization. These wafers maintain swelling behavior, structural integrity, and mechanical properties over three months of room-temperature storage, allowing pre-fabrication and on-demand use without loss of function. gECM hydrogel wafers support direct cell seeding without encapsulation and sustain viability and proliferation of human adipose-derived mesenchymal stromal cells over 21 days, with gene expression trends comparable to 3D gECM hydrogels. Furthermore, wafers can be readily integrated into microfluidic systems with in situ hydration and transport of large biomolecules. Together, this platform bridges the gap between conventional 2D culture ease-of-use and 3D biomaterial biomimicry, providing a scalable and physiologically relevant in vitro model approach for high-throughput disease studies and therapeutic screening.

bioengineering↗

Granular Extracellular Matrix (gECM) Hydrogels Enable Distinct Composition and Mechanics Across Tissue Types for Translation

Biomaterials-based tissue engineering aims to recapitulate native tissue architecture and function for both clinical repair and advanced in vitro models. While improvements in biomaterials have been made, including granular hydrogels and ECM-derived scaffolds, current biomaterials lack intentional design choices for effective translation, including regulatory considerations, practical extrusion delivery, and biomimetic characteristics. Here, we develop and characterize a library of granular ECM (gECM) biomaterials for five key tissues (cartilage, bone, skin, liver, and kidney), in which ECM particles are densely packed within a hyaluronic acid hydrogel. We optimize tissue processing methods that preserve proteomic content and structure while also aligning with scale-up manufacturing and regulatory guidelines. We show that gECM hydrogels can be molded, extruded, and 3D-printed while retaining their shape, and they stabilize at physiological temperature and pH. Lastly, we demonstrate that bulk gECM mechanics are driven by tissue type, and gECM hydrogels support viability, proliferation, and tissue-specific cellular activity. Together, these findings establish gECM hydrogels as a translational and biomimetic platform for clinical tissue repair and complex in vitro models.

bioengineering↗

Flowable Grafts Made from Granular Extracellular Matrix (gECM) Hydrogels Promote Integrative Repair of Articular Cartilage in a Large-Animal Model

Focal injuries to articular cartilage in load-bearing joints fail to heal and often progress to degeneration, underscoring the need for repair strategies that result in restored cartilage structure and function rather than fibrocartilage formation. Granular extracellular matrix (gECM) hydrogels, flowable grafts composed of densely-packed matrix particles, offer a promising approach but lack long-term functional validation in large-animal models. Here, we developed a flowable gECM hydrogel composed of decellularized cartilage microparticles incorporated within a thiol-functionalized hyaluronan matrix. Proteomic analysis confirmed enrichment of cartilage-specific gECM matrisome components. When implanted into critical-sized femoral condyle defects in a goat model and evaluated 12 months post-implantation, both gECM hydrogel and microdrilling (surgical controls) achieved >80% defect filling. However, in contrast to microdrilling, gECM repair tissue exhibited surface tribological (friction, adhesion) and compressive mechanical properties comparable to native cartilage, with a similar proteoglycan-to-collagen ratio, enrichment of type II collagen, minimal type I collagen (typical of a fibrous scar), improved quantitative MRI metrics, and evidence of lateral cartilage integration and subchondral bone remodeling. Together, these findings demonstrate that a flowable gECM hydrogel supports integrative, cartilage-like repair in a load-bearing joint, supporting advancement of this approach toward clinical translation. One Sentence SummaryA granular ECM hydrogel implanted in a goat condyle provided a robust repair, filling the defect tissue with integrated, hyaline-like cartilage at 12 months.

bioengineering↗

Characterizing the short-latency evoked response to intracortical microstimulation across a multi-electrode array

ObjectivePersons with tetraplegia can use brain-machine interfaces to make visually guided reaches with robotic arms. Without somatosensory feedback, these movements will likely be slow and imprecise, like those of persons who retain movement but have lost proprioception. Intracortical microstimulation (ICMS) has promise for providing artificial somatosensory feedback. If ICMS can mimic naturally occurring neural activity, afferent interfaces may be more informative and easier to learn than interfaces that evoke unnaturalistic activity. To develop such biomimetic stimulation patterns, it is important to characterize the responses of neurons to ICMS. ApproachUsing a Utah multi-electrode array, we recorded activity evoked by single pulses, and short (~0.2 s) and long (~4 s) trains of ICMS at a wide range of amplitudes and frequencies. As the electrical artifact caused by ICMS typically prevents recording for many milliseconds, we deployed a custom rapid-recovery amplifier with nonlinear gain to limit signal saturation on the stimulated electrode. Across all electrodes after stimulation, we removed the remaining slow return to baseline with acausal high-pass filtering of time-reversed recordings. With these techniques, we could record ~0.7 ms after stimulation offset even on the stimulated electrode. Main resultsWe recorded likely transsynaptically-evoked activity as early as ~0.7 ms after single pulses of stimulation that was immediately followed by suppressed neural activity lasting 10-150 ms. Instead of this long-lasting inhibition, neurons increased their firing rates for ~100 ms after trains. During long trains, the evoked response on the stimulated electrode decayed rapidly while the response was maintained on non-stimulated channels. SignificanceThe detailed description of the spatial and temporal response to ICMS can be used to better interpret results from experiments that probe circuit connectivity or function of cortical areas. These results can also contribute to the design of stimulation patterns to improve afferent interfaces for artificial sensory feedback.

neuroscience↗