Optical ice thickness measurement in the VitroJet for time-efficient single particle structure determination

Embedding biomolecules in vitreous ice of optimal thickness is critical for structure determination by cryo-electron microscopy. Ice thickness assessment and selection of suitable holes for data collection are currently part of time-consuming preparatory routines performed on expensive electron microscopes. To address this challenge, a routine has been developed to measure ice thickness during sample preparation using an optical camera integrated in the VitroJet. This method allows to estimate the ice thickness with an error below {+/-} 20 nm for ice layers in the range of 0 - 70 nm. Additionally, we implemented pin printing to reproduce and control sample deposition in the VitroJet. The median ice thickness can be reproduced with a standard deviation below {+/-} 11 nm for thicknesses up to 75 nm. Therefore, the ice thickness of buffer-suspended holes on an EM grid can be tuned and measured within the working range relevant for single particle cryo-EM. Single particle structures of apoferritin were determined at two distinct thicknesses of 30 nm and 70 nm. These reconstructions demonstrate the importance of ice thickness for time-efficient cryo-EM structure determination. HighlightsO_LIMethods in the VitroJet allow for on-the-fly ice thickness tuning and measurement C_LIO_LIThe optical camera can estimate ice thickness ranging from 0 - 70 {+/-} 20 nm C_LIO_LIPin printing enables to reproduce and control median ice thickness up to 75 {+/-} 11 nm C_LIO_LIStructures of apoferritin require 3.7 x fewer particles in 30 compared to 70 nm ice C_LI

molecular biology↗

Automated cryo-EM sample preparation by pin-printing and jet vitrification

The increasing demand for cryo-electron microscopy (cryo-EM) reveals drawbacks in current sample preparation protocols, such as sample waste and lack of reproducibility. Here, we present several technical developments that provide controlled and efficient sample preparation for cryo-EM studies. Pin printing substantially reduces sample waste by depositing only a sub-nanoliter volume of sample on the carrier surface. Sample evaporation is mitigated by dewpoint control feedback loops. The deposited sample is vitrified by jets of cryogen followed by submersion into a cryogen bath. Because the cryogen jets cool the sample from the center, premounted autogrids can be used and loaded directly into automated cryo-EMs. We integrated these steps into a single device, named VitroJet. The devices performance was validated by resolving 4 standard proteins (apoferritin, GroEL, worm hemoglobin, beta-galactosidase) to ~3 [A] resolution using a 200-kV electron microscope. The VitroJet offers a promising solution for improved automated sample preparation in cryo-EM studies.

biophysics↗