Search bioRxiv⌕ Search

Biology subjects

Hattne, J.

Publications and source records attributed to Hattne, J..

At least 19 recordsLinked to original sources

Characterization of energy filtering slit widths for MicroED data collection

A favorable signal-to-noise ratio is essential for obtaining high-quality diffraction data in macromolecular electron crystallography. Inelastic scattering contributes significantly to the noise, reducing contrast between diffraction peaks and background, which complicates peak detection and compromises the accuracy of intensity integration. Energy filtering mitigates these challenges and enhances diffraction data quality by removing the inelastically scattered electrons, leading to reduced background noise and sharper Bragg peaks. Previously, we reported a substantial improvement in MicroED data quality and resolution with energy filtering. Here, we systematically evaluate the impact of different energy filter slit widths for optimal MicroED data collection. Data from proteinase K lamellae were collected using the 5, 10, and 20 eV energy filter slit widths. Our results show that the narrowest slit widths result in a stronger diffraction signal with lower background noise, improving the precision of the intensity measurements which resulted in better structural models. Our findings provide insights into the optimization of energy filter slit settings that, when paired with direct electron detection, enhance MicroED data collection strategies in MicroED by improving the signal-to-noise ratio, supporting higher quality data and ultimately enabling more precise structure determination.

biochemistry↗

High-throughput MicroED for probing ion channel dynamics

Ion channels play a crucial role in ion transport and are integral to fundamental physiological processes. Therefore, understanding channel structures is essential for elucidating the mechanisms of ion permeation and selectivity beyond what can be predicted by computational simulations. Visualizing dynamics at high resolution, however, remains a significant challenge by structural techniques. In this study, we apply high-throughput Microcrystal Electron Diffraction (MicroED) to explore the structural dynamics of two ion channels, the non-selective ion channel NaK and its mutant, NaK2CNG. This approach utilizes automated data collection and processing to capture distinct structural substates from a large number of microcrystals, offering a deeper understanding of ion channel mechanisms. From a subset of NaK structures, we observed consistent sodium binding at specific sites. In contrast, NaK2CNG appears more dynamic and undergoes dilation of the selectivity filter upon potassium binding. Further, the conduction state of NaK2CNG appears to be influenced by channel gating. Comparative analysis of these structures reveals that non-selectivity arises from the plasticity of the selectivity filter, allowing dynamic control over ion passage. These studies, demonstrate the potential to employ high-throughput MicroED as a technique to address persistent questions regarding ion channel permeation, complementing current computational molecular dynamics studies. We anticipate that this approach will enhance future computational models, leading to more accurate predictions of ion channel behavior and providing a more comprehensive view of transport dynamics.

biochemistry↗

Ligand Screening and Discovery using Cocktail Soakingand Automated MicroED

Cocktail soaking using single-crystal X-ray diffraction (SC-XRD) has previously allowed high-throughput crystallographic screening of ligands against protein targets. However, protein microcrystals are not amenable to this approach if they are too small to yield strong diffraction patterns. In this study, we developed a workflow integrating cocktail soaking with automated microcrystal electron diffraction (MicroED) to allow rapid ligand screening, structure determination, and binding analysis directly from microcrystals. This can improve the successful hit rate, because binding is often more efficient when smaller crystals are soaked in the ligand. The approach was validated with known ligands of thermolysin and identified novel binding interactions for ligands of proteinase K. The structures of multiple protein-ligand complexes, including ligands with weak binding affinities, could be solved quickly. Their estimated relative binding affinities are in good agreement with previous work and independent microscale thermophoresis (MST) measurements.

biochemistry↗

Energy filtering enables macromolecular MicroED data at sub-atomic resolution

High resolution information is important for accurate structure modelling. However, this level of detail is typically difficult to attain in macromolecular crystallography because the diffracted intensities rapidly fade with increasing resolution. The problem cannot be circumvented by increasing the fluence as this leads to detrimental radiation damage. Previously, we demonstrated that high quality MicroED data can be obtained at low flux conditions using electron counting with direct electron detectors. The improved sensitivity and accuracy of these detectors essentially eliminate the read-out noise, such that the measurement of faint high-resolution reflections is limited by other sources of noise. Inelastic scattering is a major contributor of such noise, increasing background counts and broadening diffraction spots. Here, we demonstrate that a substantial improvement in signal-to-noise ratio can be achieved using an energy filter to largely remove the inelastically scattered electrons. This strategy resulted in sub-atomic resolution MicroED data from proteinase K crystals, enabling accurate structure modelling and the visualization of detailed features. Interestingly, filtering out the noise revealed diffuse scattering phenomena that can hold additional structural information. Our findings suggest that combining energy filtering and electron counting can provide more accurate measurements at higher resolution, providing better insights into protein function and facilitating more precise model refinement.

biochemistry↗

Eliminating the missing cone challenge through innovative approaches

Microcrystal electron diffraction (MicroED) has emerged as a powerful technique for unraveling molecular structures from microcrystals too small for X-ray diffraction. However, a significant hurdle arises with plate-like crystals that consistently orient themselves flat on the electron microscopy grid. If, as is typically the case, the normal of the plate correlates with the axes of the crystal lattice, the crystal orientations accessible for measurement are restricted because the grid cannot be arbitrarily rotated. This limits the information that can be acquired, resulting in a missing cone of information. We recently introduced a novel crystallization strategy called suspended drop crystallization and proposed that this method could effectively address the challenge of preferred crystal orientation. Here we demonstrate the success of the suspended drop crystallization approach in eliminating the missing cone in two samples that crystallize as thin plates: bovine liver catalase and the COVID-19 main protease (Mpro). This innovative solution proves indispensable for crystals exhibiting preferred orientations, unlocking new possibilities for structure determination by MicroED.

biochemistry↗

Electron-counting in MicroED

The combination of high sensitivity and rapid readout makes it possible for electron-counting detectors to record cryogenic electron microscopy data faster and more accurately without increasing the exposure. This is especially useful for MicroED of macromolecular crystals where the strength of the diffracted signal at high resolution is comparable to the surrounding background. The ability to decrease the exposure also alleviates concerns about radiation damage which limits the information that can be recovered from a diffraction measurement. However, the dynamic range of electron-counting detectors requires careful data collection to avoid errors from coincidence loss. Nevertheless, these detectors are increasingly deployed in cryo-EM facilities, and several have been successfully used for MicroED. Provided coincidence loss can be minimized, electron-counting detectors bring high potential rewards.

biochemistry↗

A robust approach for MicroED sample preparation of lipidic cubic phase embedded membrane protein crystals

Crystallization of membrane proteins, such as G protein-coupled receptors (GPCRs), is challenging and frequently requires the use of lipidic cubic phase (LCP) crystallization methods. These typically yield crystals that are too small for synchrotron X-ray crystallography, but ideally suited for the cryogenic electron microscopy (cryoEM) method microcrystal electron diffraction (MicroED). However, the viscous nature of LCP makes sample preparation challenging. The LCP layer is often too thick for transmission electron microscopy (TEM), and crystals buried in LCP cannot be identified topologically using a focused ion-beam and scanning electron microscope (FIB/SEM). Therefore, the LCP needs to either be converted to the sponge phase or entirely removed from the path of the ion-beam to allow identification and milling of these crystals. Unfortunately, conversion of the LCP to sponge phase can also deteriorate the sample. Methods that avoid LCP conversion are needed. Here, we employ a novel approach using an integrated fluorescence light microscope (iFLM) inside of a FIB/SEM to identify fluorescently labelled crystals embedded deep in a thick LCP layer. The crystals are then targeted using fluorescence microscopy and unconverted LCP is removed directly using a plasma focused ion beam (pFIB). To assess the optimal ion source to prepare biological lamellae, we first characterized the four available gas sources on standard crystals of the serine protease, proteinase K. However, lamellae prepared using either argon and xenon produced the highest quality data and structures. Fluorescently labelled crystals of the human adenosine receptor embedded in thick LCP were placed directly onto EM grids without conversion to the sponge phase. Buried microcrystals were identified using iFLM, and deep lamellae were created using the xenon beam. Continuous rotation MicroED data were collected from the exposed crystalline lamella and the structure was determined using a single crystal. This study outlines a robust approach to identifying and milling LCP grown membrane protein crystals for MicroED using single microcrystals, and demonstrates plasma ion-beam milling as a powerful tool for preparing biological lamellae.

biochemistry↗

Electron-counting MicroED data with the K2 and K3 direct electron detectors

Microcrystal electron diffraction (MicroED) uses electron cryo-microscopy (cryo-EM) to collect diffraction data from small crystals during continuous rotation of the sample. As a result of advances in hardware as well as methods development, the data quality has continuously improved over the past decade, to the point where even macromolecular structures can be determined ab initio. Detectors suitable for electron diffraction should ideally have fast readout to record data in movie mode, and high sensitivity at low exposure rates to accurately report the intensities. Direct electron detectors are commonly used in cryo-EM imaging for their sensitivity and speed, but despite their availability are generally not used in diffraction. Primary concerns with diffraction experiments are the dynamic range and coincidence loss, which will corrupt the measurement if the flux exceeds the count rate of the detector. Here, we describe instrument setup and low-exposure MicroED data collection in electron-counting mode using K2 and K3 direct electron detectors and show that the integrated intensities can be effectively used to solve structures of two macromolecules between 1.2 [A] and 2.8 [A]. Even though a beam stop was not used in these studies we did not observe damage to the camera. As these cameras are already available in many cryo-EM facilities, this provides opportunities for users who do not have access to dedicated facilities for MicroED.

biochemistry↗

Hydrogens and hydrogen-bond networks in macromolecular MicroED data

Microcrystal electron diffraction (MicroED) is a powerful technique utilizing electron cryo-microscopy (cryo-EM) for protein structure determination of crystalline samples too small for X-ray crystallography. Electrons interact with the electrostatic potential of the sample, which means that scattered electrons carry informing about the charged state of atoms and can provide strong contrast for visualizing hydrogen atoms. Accurately identifying the positions of hydrogen atoms, and by extension the hydrogen bonding networks, is of importance for drug discovery and electron microscopy can enable such visualization. Using subatomic resolution MicroED data obtained from triclinic hen egg-white lysozyme, we identified hundreds of individual hydrogen atom positions and directly visualize hydrogen bonding interactions and the charged states of residues. Over a third of all hydrogen atoms are identified from strong difference peaks, the most complete view of a macromolecular hydrogen network visualized by electron diffraction to date. These results show that MicroED can provide accurate structural information on hydrogen atoms and non-covalent hydrogen bonding interactions in macromolecules. Furthermore, we find that the hydrogen bond lengths are more accurately described by the inter-nuclei distances than the centers of mass of the corresponding electron clouds. We anticipate that MicroED, coupled with ongoing advances in data collection and refinement, can open further avenues for structural biology by uncovering and understanding the hydrogen bonding interactions underlying protein structure and function.

biochemistry↗

Ab initio phasing macromolecular structures using electron-counted MicroED data

Structures of two globular proteins were determined ab initio using microcrystal electron diffraction (MicroED) data that was collected on a direct electron detector in counting mode. Microcrystals were identified using a scanning electron microscope (SEM) and thinned with a focused ion-beam (FIB) to produce crystalline lamellae of ideal thickness. Continuous rotation data were collected using an ultra-low exposure rate on a Falcon 4 direct electron detector in electron-counting mode. For the first sample, triclinic lysozyme extending to 0.87 [A] resolution, an ideal helical fragment of only three alanine residues provided initial phases. These phases were improved using density modification, allowing the entire atomic structure to be built automatically. A similar approach was successful on a second macromolecular sample, proteinase K, which is much larger and diffracted to a modest 1.5 [A] resolution. These results demonstrate that macromolecules can be determined to sub-[A]ngstrom resolution by MicroED and that ab initio phasing can be successfully applied to counting data collected on a direct electron detector.

biochemistry↗

Benchmarking ideal sample thickness in cryo-EM using MicroED

The relationship between sample thickness and quality of data obtained by microcrystal electron diffraction (MicroED) is investigated. Several EM grids containing proteinase K microcrystals of similar sizes from the same crystallization batch were prepared. Each grid was transferred into a focused ion-beam scanning electron microscope (FIB/SEM) where the crystals were then systematically thinned into lamellae between 95 nm and 1650 nm thick. MicroED data were collected at either 120, 200, or 300 kV accelerating voltages. Lamellae thicknesses were converted to multiples of the calculated inelastic mean free path (MFP) of electrons at each accelerating voltage to allow the results to be compared on a common scale. The quality of the data and subsequently determined structures were assessed using standard crystallographic measures. Structures were reliably determined from crystalline lamellae only up to twice the inelastic mean free path. Lower resolution diffraction was observed at three times the mean free path for all three accelerating voltages but the quality was insufficient to yield structures. No diffraction data were observed from lamellae thicker than four times the calculated inelastic mean free path. The quality of the determined structures and crystallographic statistics were similar for all lamellae up to 2x the inelastic mean free path in thickness, but quickly deteriorated at greater thicknesses. This study provides a benchmark with respect to the ideal limit for biological specimen thickness with implications for all cryo-EM methods. SignificanceA systematic investigation of the effects of thickness on electron scattering from protein crystals was previously not feasible, because there was no accurate method to control sample thickness. Here, the recently developed methods for preparing protein crystals into lamellae of precise thickness by ion-beam milling are used to investigate the effects of increasing sample thickness on MicroED data quality. These experiments were conducted using the three most common accelerating voltages in cryo-EM. Data across these accelerating voltages and thicknesses were compared on a common scale using their calculated inelastic mean free path lengths. It is found that structures may accurately be determined from crystals up to twice the inelastic mean free path length in thickness, regardless of the acceleration voltage.

biochemistry↗

MicroED structure of the human adenosine receptor determined from a single nanocrystal in LCP

G Protein-Coupled Receptors (GPCRs), or 7-transmembrane receptors, are a superfamily of membrane proteins that are critically important to physiological processes in the human body. Determining high-resolution structures of GPCRs without signaling partners bound requires crystallization in lipidic cubic phase (LCP). GPCR crystals grown in LCP are often too small for traditional X-ray crystallography. These microcrystals are ideal for investigation by microcrystal electron diffraction (MicroED), but the gel-like nature of LCP makes traditional approaches to MicroED sample preparation insurmountable. Here we show that the structure of a human A2A adenosine receptor can be determined by MicroED after converting the LCP into the sponge phase followed by cryoFIB milling. We determined the structure of the A2A receptor to 2.8 [A] resolution and resolved an antagonist in its orthosteric ligand-binding site as well as 4 cholesterol molecules bound to the receptor. This study lays the groundwork for future GPCR structural studies using single microcrystals that would otherwise be impossible by other crystallographic methods. One sentence summaryFIB milled LCP-GPCR structure determined by MicroED

biophysics↗

MicroED structure of lipid-embedded mammalian mitochondrial voltage dependent anion channel

A near-atomic resolution structure of the mouse voltage dependent anion channel (mVDAC) is determined by combining cryogenic focused ion-beam (FIB) milling and microcrystal electron diffraction (MicroED). The crystals were grown in a viscous modified bicelle suspension which limited their size and made them unsuitable for conventional X-ray crystallography. Individual thin, plate-like crystals were identified using scanning electron microscopy (SEM) and focused ion-beam (FIB) imaging at high magnification. Three crystals were milled into thin lamellae. MicroED data were collected from each lamellae and merged to increase completeness. Unmodelled densities were observed between protein monomers, suggesting the presence of lipids that likely mediate crystal contacts. This work demonstrates the utility of milling membrane protein microcrystals grown in viscous media using a focused ion-beam for subsequent structure determination by MicroED for samples that are not otherwise tractable by other crystallographic methods. To our knowledge, the structure presented here is the first of a membrane protein crystallized in a lipid matrix and solved by MicroED.

biophysics↗

Experimental phasing of MicroED data using radiation damage

We present an example of an experimentally phased structure using only MicroED. The structure of a seven-residue peptide is determined starting from differences to the diffraction intensities induced by structural changes due to radiation damage. The same wedge of reciprocal space was recorded twice by continuous rotation MicroED from a set of 11 individual crystals. The data from the first pass were merged to make a \"low-dose dataset\". The data from the second pass were similarly merged to form a \"damaged dataset.\" Differences between these two datasets were used to calculate a Patterson difference map and to identify a single heavy atom site, from which initial phases were generated. The structure was then completed by iterative cycles of modeling and refinement.

biophysics↗

MicroED with the Falcon III direct electron detector

Microcrystal electron diffraction (MicroED) combines crystallography and electron cryomicroscopy (cryo-EM) into a method that can be used for high-resolution structure determination. In MicroED nanosized crystals, often intractable by other techniques, are probed by high-energy electrons in a transmission electron microscope and the diffracted signal is recorded on an electron detector. Since only a small number of different detectors have been used for MicroED measurements in the past, their impact on data quality has not been investigated. Here we evaluate two different cameras using crystals of the well-characterized serine protease proteinase K. Compared to previously used equipment, the Falcon III direct electron detector and the CMOS-based CetaD camera can collect complete datasets both faster and using lower total exposure. As an effect of the lower dose, radiation damage is reduced, which is confirmed in both real and reciprocal space. The increased speed and lower exposure requirements have implications on model quality and the prospects for further automation of MicroED.

biochemistry↗

Qualitative analyses of polishing and pre-coating FIB milled crystals for MicroED

Microcrystal electron diffraction (MicroED) leverages the strong interaction between matter and electrons to determine protein structures from vanishingly small crystals. This strong interaction limits the thickness of crystals that can be investigated by MicroED, mainly due to absorption. Recent studies have demonstrated that focused ion beam (FIB) can thin even very large crystals into ideal sized lamellae however it is not clear how to best apply FIB-milling for MicroED. Here, The effects of polishing the lamellae, whereby the last few nanometers are milled away using a low-current gallium beam, are explored in both platinum pre-coated and uncoated samples. Our results suggest that pre-coating samples with a thin layer of platinum followed by polishing the crystal surfaces prior to data collection consistently led to superior results as indicated by higher signal/noise ratio, higher resolution and better refinement statistics. This study lays the foundation for routine and reproducible methodology for sample preparation in MicroED.

biochemistry↗

MicroED data collection with SerialEM

We developed a procedure for the cryoEM method MicroED using SerialEM. With this approach, SerialEM coordinates stage rotation, microscope operation, and camera functions for automated continuous-rotation MicroED data collection. More than 300 datasets can be collected overnight in this way, facilitating high-throughput MicroED data collection for large-scale data analyses.

biophysics↗

Collection of continuous rotation MicroED Data from Ion Beam Milled Crystals of Any Size

Microcrystal electron diffraction (MicroED) allows for macromolecular structure solution from nanocrystals. To create crystals of suitable size for MicroED data collection, sample preparation typically involves sonication or pipetting a slurry of crystals from a crystallization drop. The resultant crystal fragments are fragile and the quality of the data that can be obtained from them is sensitive to subsequent sample preparation for cryoEM as interactions in the water-air interface can damage crystals during blotting. Here, we demonstrate the use of a focused ion beam to generate lamellae of macromolecular protein crystals for continuous rotation MicroED that are of ideal thickness, easy to locate, and require no blotting optimization. In this manner, crystals of nearly any size may be scooped and milled to ideal dimensions prior to data collection, thus streamlining the methodology for sample preparation for MicroED.

biochemistry↗