High Resolution Multi-Pass Astral Analyzer Quantification Enables Highly Multiplexed 35-Plex Tandem Mass Tag Proteomics

Tandem mass tags (TMT) allow highly multiplexed and thus high-throughput, precisely quantitative proteomic analysis. Incorporation of additional deuterated reporter channels has near-doubled the multiplexation achieved with Thermo Scientific TMTpro reagents from 18 to 35-plex but requires extremely high [~]100k analyzer resolving power at m/z 128 to differentiate and quantify reporter ion channels, far beyond any single reflection time-of-flight analyzer, and exceeding the multi-reflection Thermo Scientific Astral analyzer in its standard operation. A multi-pass mode of Astral operation has been developed for the Thermo Scientific Orbitrap Astral Zoom mass spectrometer that triples the ion path to 90 m, more than doubling resolving power for a narrow m/z range. This "TMT HR mode" has been integrated into a new method of TMT proteomic analysis that splits regular MS2 analysis of labeled peptides into paired measurements comprising wide mass range scans for peptide identification, and TMT HR mode scans for reporter ion quantification. The method has been shown to accurately quantify 32-plex labeled HeLa protein lysate and provide far greater depth of analysis as state-of-the-art Orbitrap-only methods, while analysis of 11-plex labeled yeast showed no analytical depth sacrificed vs regular Orbitrap Astral TMT analysis. Further comparative measurements of a 2-cell line 35-plex sample demonstrated greater analytical depth, and similar quantitative precision, to "gold standard" Orbitrap MS3 methods.

biochemistry↗

Higher-Throughput Proteome Profiling Enabled by Parallelized Pre-Accumulation and Optimized Ion Processing in the Orbitrap Astral Zoom Mass Spectrometer

High-throughput proteomics is critical for understanding biological processes, enabling large-scale studies such as biomarker discovery and systems biology. However, current mass spectrometry technologies face limitations in speed, sensitivity, and scalability for analyzing large sample cohorts. The Thermo Scientific Orbitrap Astral Zoom mass spectrometer (MS) was developed to address these limitations by improving acquisition speed, ion utilization, and spectral processing, which are all essential for advancing proteome depth in high-throughput proteomics. The Orbitrap Astral Zoom MS achieves ultra-fast MS/MS scan rates of up to 270 Hz with enhanced ion utilization through pre-accumulation, enabling the identification of [~]100,000 unique peptides and >8,400 proteins in a single 300 samples-per-day (SPD) analysis of human cell lysate. The optimized system reduces analysis time by 40%, achieves near-complete proteome coverage (>12,000 proteins) in 2.7 hours, and enables ultra-high-throughput workflows, identifying >7,000 proteins in a 500 SPD method with exceptional reproducibility (Pairwise Pearson correlations >0.99). These advancements establish the Orbitrap Astral Zoom MS as a new benchmark in proteomics, significantly enhancing speed, sensitivity, and scalability, paving the way for routine large-scale proteome studies with applications in clinical research and systems biology. TeaserHigh-Speed Human Proteome Analysis using the Orbitrap Astral Zoom Mass Spectrometer

biochemistry↗

Evaluation of an Orbitrap Astral Zoom mass spectrometer prototype for quantitative proteomics - beyond identification lists

Mass spectrometry instrumentation continues to evolve rapidly yet quantifying these advances beyond conventional peptide and protein detections remain challenging. Here, we evaluate a modified Orbitrap Astral Zoom mass spectrometer (MS) prototype and compare its performance to the standard Orbitrap Astral MS. Across a range of acquisition methods and sample inputs, the prototype instrument outperformed the standard Orbitrap Astral MS in precursor and protein identifications, ion beam utilization, and quantitative precision. To enable meaningful cross-platform comparisons, we implemented an ion calibration framework that converts signal intensity from arbitrary units to ion per second. This benchmarking strategy showed that the prototype sampled 30% more ions per peptide than the original Orbitrap Astral MS. This increase in the ion beam utilization resulted in improved sensitivity and quantitative precision. To make these metrics broadly accessible, we added new metrics to the Skyline document grid to report the number of ions measured in a spectrum at the apex of the elution peak or the sum of ions between the peak integration boundaries. Taken together, our results demonstrate the prototype Orbitrap Astral Zoom as a high-performance platform for DIA proteomics and establish a generalizable framework for evaluation of mass spectrometer performance based on the number of ions detected for each analyte. Data are available on Panorama Public and on ProteomeXchange under the identifier PXD064536.

biochemistry↗

Parallelized Acquisition of Orbitrap and Astral Analyzers Enables High-Throughput Quantitative Analysis.

The growing trend towards high-throughput proteomics demands rapid liquid chromatography-mass spectrometry (LC-MS) cycles that limit the available time to gather the large numbers of MS/MS fragmentation spectra required for identification. Orbitrap analyzers scale performance with acquisition time, and necessarily sacrifice sensitivity and resolving power to deliver higher acquisition rates. We developed a new mass spectrometer that combines a mass resolving quadrupole, the Orbitrap and the novel Asymmetric Track Lossless (Astral) analyzer. The new hybrid instrument enables faster acquisition of high-resolution accurate mass (HRAM) MS/MS spectra compared to state-of-the-art mass spectrometers. Accordingly, new proteomics methods were developed that leverage the strengths of each HRAM analyzer, whereby the Orbitrap analyzer performs full scans with high dynamic range and resolution, synchronized with Astral analyzers acquisition of fast and sensitive HRAM MS/MS scans. Substantial improvements are demonstrated over previous methods using current state-of-the-art mass spectrometers. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=100 SRC="FIGDIR/small/543408v1_ufig1.gif" ALT="Figure 1"> View larger version (35K): org.highwire.dtl.DTLVardef@1eedfdeorg.highwire.dtl.DTLVardef@1ab7939org.highwire.dtl.DTLVardef@a3b2f8org.highwire.dtl.DTLVardef@13ac46b_HPS_FORMAT_FIGEXP M_FIG C_FIG

cell biology↗

Evidence of the Cost-Efficiency of Scale as seen in Polio Vaccination and Surveillance Costs

This analysis examined how polio program costs vary with scale for vaccination and disease surveillance, based on historical budget data published by the Global Polio Eradication Initiative (GPEI) from 2005 to 2018. We applied a linear mixed effects regression model in order to understand the cost structure of the historical GPEI budgets, with the goal that lessons learned from polio may be extended to other global disease elimination programs. Our findings demonstrate that there are economies of scale for vaccine delivery operations and for disease surveillance, which means that larger programs can leverage fixed costs and achieve better cost-efficiency as they scale. This finding should enable decision makers to create more reliable budgets, which support fundraising and optimal resource allocation. They also provide insight into how cost effectiveness changes as programs scale up during progressive disease control and elimination, as well as what level of resources are needed to sustain a program that is scaling back post-eradication and through to certification.