Search bioRxiv⌕ Search

Biology subjects

Greenwood, H. E.

Publications and source records attributed to Greenwood, H. E..

4 recordsLinked to original sources

System xc- imaging maps ferroptosis-linked redox remodeling in cancer

Ferroptosis is a regulated non-apoptotic form of programmed cell death that is implicated in tumor suppression and the normal tissue damage response. While the link between redox stress and ferroptosis is well established, no non-invasive methods exist to assess ferroptosis in vivo. Here, we demonstrate that the redox-sensitive positron emission tomography radiotracer and system xc-substrate, 18F-(S)-4-(3-fluoropropyl)-L-glutamic acid ([18F]FSPG), serves as a non-invasive marker of tumor ferroptosis. Global changes in amino acids, glutathione, and system xc- activity occurred before loss of membrane integrity in cells sensitive to ferroptosis, but not in resistant cells. Resistant cells sensitized to ferroptosis through nuclear factor erythroid 2-related factor 2 (NRF2) knockout had reduced glutathione and [18F]FSPG retention, which were rescued by ferroptosis inhibitors. In vivo, immune checkpoint blockade decreased ferroptosis-specific [18F]FSPG tumor retention prior to immune cell infiltration. Together, our data demonstrate that [18F]FSPG can identify early redox changes that precede ferroptosis and enabled real-time monitoring of immunotherapeutic efficacy.

cancer biology↗

Imaging the master regulator of the antioxidant response in non-small cell lung cancer with positron emission tomography

Mutations in the NRF2-KEAP1 pathway are common in non-small cell lung cancer (NSCLC) and confer broad-spectrum therapeutic resistance, leading to poor outcomes. The cystine/glutamate antiporter, system xc-, is one of the >200 cytoprotective proteins controlled by NRF2, which can be non-invasively imaged by (S)-4-(3-18F-fluoropropyl)--glutamate ([18F]FSPG) positron emission tomography (PET). Through genetic and pharmacologic manipulation, we show that [18F]FSPG provides a sensitive and specific marker of NRF2 activation in advanced preclinical models of NSCLC. We validate imaging readouts with metabolomic measurements of system xc- activity and their coupling to intracellular glutathione concentration. A redox gene signature was measured in patients from the TRACERx 421 cohort, suggesting an opportunity for patient stratification prior to imaging. Furthermore, we reveal that system xc- is a metabolic vulnerability that can be therapeutically targeted for sustained tumour growth suppression in aggressive NSCLC. Our results establish [18F]FSPG as predictive marker of therapy resistance in NSCLC and provide the basis for the clinical evaluation of both imaging and therapeutic agents that target this important antioxidant pathway.

cancer biology↗

The Chicken Chorioallantoic Membrane as a Low-Cost, High-Throughput Model for Cancer Imaging

PurposeMouse models are invaluable tools for radiotracer development and validation. They are, however, expensive, low throughput, and are constrained by animal welfare considerations. Here, we assessed the chicken chorioallantoic membrane (CAM) as an alternative to mice for preclinical cancer imaging studies. MethodsGrowth of NCI-H460 Fluc tumors on the CAM was optimized using a range of physical and chemical supports. Tumor-bearing eggs were imaged by dynamic 18F-2-fluoro-2-deoxy-D-glucose (18F-FDG) or (4S)-4-(3-18F-fluoropropyl)-L-glutamate (18F-FSPG) PET/CT following intravenous injection, with mice bearing subcutaneous NCI-H460 Fluc xenografts imaged with 18F-FDG for comparison. The dependence of the transporter system xc- on in ovo 18F-FSPG tumor uptake was determined through treatment with imidazole ketone erastin. Additionally, 18F-FSPG PET/CT was used to monitor treatment response in ovo 24 h following external beam radiotherapy. ResultsNCI-H460 Fluc cells grown in Matrigel formed vascularized tumors of reproducible size without compromising embryo viability. By designing a simple method for cannulation it was possible to perform dynamic PET imaging in ovo, producing high tumor-to-background signal for both 18F-FDG and 18F-FSPG. 18F-FDG tumor uptake kinetics were similar in ovo and in vivo, with 18F-FSPG providing an early marker of both treatment response and target inhibition in CAM-grown tumors. ConclusionsThe CAM provides a low-cost alternative to tumor xenograft mouse models which may broaden access to PET and SPECT imaging. Rapid tumor growth and high-quality PET images that can be obtained with this model suggest its potential use for early radiotracer screening, pharmacological studies, and monitoring response to therapy.

cancer biology↗

High Throughput PET/CT Imaging Using a Multiple Mouse Imaging System

A considerable limitation of current small animal positron emission tomography/computed tomography (PET/CT) imaging is the low throughput of image acquisitions. Subsequently, to design sufficiently-powered studies, high costs accumulate. Together with Mediso Medical Imaging Systems, a four-bed mouse hotel was developed to simultaneously image up to four mice, thereby reducing the cost and maximising radiotracer usage when compared to scans performed with a single mouse bed.\n\nMethodsFor physiological evaluation of the four-bed mouse hotel, temperature and anaesthesia were tested for uniformity, followed by [18F]fluorodeoxyglucose (FDG) PET/CT imaging of mini image quality (IQ) phantoms specifically designed to fit the new imaging system. Post-reconstruction, National Electrical Manufacturers Association (NEMA) NU-4 tests examined uniformity, recovery coefficients (RCs) and spill-over ratios (SORs). To evaluate the bed under standard in vivo imaging conditions, four mice were simultaneously scanned by dynamic [18F]FDG PET/CT over 60 minutes using the four-bed mouse hotel, with quantified images compared to those acquired using a single mouse bed.\n\nResultsThe bed maintained a constant temperature of 36.8{degrees}C {+/-} 0.4{degrees}C (n = 4), with anaesthesia distributed evenly to each nose cone (2.9 {+/-} 0.1 L/min, n = 4). The NEMA tests performed on reconstructed mini IQ phantom images acquired using the four-bed mouse hotel revealed values within the tolerable limits for uniformity, RC values in >2mm rods, and SORs in the non-radioactive water- and air-filled chambers. There was low variability in radiotracer uptake in all major organs of mice scanned using the four-animal bed versus those imaged using a single bed imaging platform.\n\nConclusionAnalysis of images acquired using the four-bed mouse hotel confirmed its utility to increase the throughput of small animal PET imaging without considerable loss of image quality and quantitative precision. In comparison to a single mouse bed, the cost and time associated with each scan were substantially reduced.

bioengineering↗