Search bioRxivSearch

Biology subjects

Gaunt, R.

Publications and source records attributed to Gaunt, R..

4 recordsLinked to original sources

Perceptual responses to microstimulation frequency are spatially organized in human somatosensory cortex

Microstimulation in the somatosensory cortex can evoke artificial tactile percepts and can be incorporated into bidirectional brain-computer interfaces (BCIs) to restore function after injury or disease. However, little is known about how stimulation parameters themselves affect perception. Here, we stimulated through microelectrode arrays implanted in the somatosensory cortex of a human participant with a cervical spinal cord injury and varied the stimulus amplitude, duration, and frequency. Increasing the amplitude and duration increased the perceived intensity on all tested electrodes. Surprisingly, we found that increasing the frequency evoked more intense percepts on some electrodes but evoked less intense percepts on most electrodes. Electrodes divided into three groups which evoked distinct perceptual qualities that depended on the stimulus frequency and were spatially organized in cortex. These results contribute to our growing understanding of the structure and function of the somatosensory cortex and will facilitate principled development of stimulation strategies for bidirectional BCIs.

neuroscience

Functional and Structural Moment Arm Validation for Musculoskeletal Models: A Study of the Human Forearm and Hand

The development of realistic musculoskeletal models is a fundamental goal for the theoretical progress in sensorimotor control and its engineering applications, e.g., in the biomimetic control of artificial limbs. Yet, accurate models require extensive experimental measures to validate structural and functional parameters describing muscle state over the full physiological range of motion. However, available experimental measurements of, for example, muscle moment arms are sparse and often disparate. Validation of these models is not trivial because of the highly complex anatomy and behavior of human limbs. In this study, we developed a method to validate and scale kinematic muscle parameters using posture-dependent moment arm profiles, isometric force measurements, and a computational detection of assembly errors. We used a previously published model with 18 degrees of freedom (DOFs) and 32 musculotendon actuators with force generated from a Hill-type muscle model. The muscle path from origin to insertion with wrapping geometry was used to model the muscle lengths and moment arms. We simulated moment arm profiles across the full physiological range of motion and compared them to an assembled dataset of published and merged experimental profiles. The muscle paths were adjusted using custom metrics based on root-mean-square and correlation coefficient of the difference between simulated and experimental values. Since the available measurements were sparse and the examination of high-dimensional muscles is challenging, we developed analyses to identify common failures, i.e., moment arm functional flipping due to the sign reversal in simulated moments and the imbalance of force generation between antagonistic groups in postural extremes. The validated model was used to evaluate the expected errors in torque generation with the assumption of constant instead of the posture-dependent moment arms at the wrist flexion-extension DOF, which is the critical joint in our model with the largest number of crossing muscles. We found that there was a reduction of joint torques by about 35% in the extreme quartiles of the wrist DOF. The use of realistic musculoskeletal models is essential for the reconstruction of hand dynamics. These models may improve the understanding of muscle actions and help in the design and control of artificial limbs in future applications. New & NoteworthyRealistic models of human limbs are a development goal required for the understanding of motor control and its applications in biomedical fields. However, developing accurate models is restrained by the lack of accurate and reliable musculoskeletal measurements in humans. Here, we have overcome this challenge by using multi-stage validation of simulated structures using both experimental data and the identification of structural failures in the high-dimensional muscle paths. We demonstrate that the rigorous structural and functional validation method is essential for the understanding of force generation at the wrist.

neuroscience

Heuristic Spike Sorting Tuner (HSST), a framework to determine optimal parameter selection for a generic spike sorting algorithm

Bj[a]nes DA, Fisher LE, Gaunt RA, Weber DJHeuristic Spike Sorting Tuner (HSST), a framework to determine optimal parameter selection for a generic spike sorting algorithm. bioRxiv First published May 21, 2020. Extracellular microelectrodes frequently record neural activity from more than one neuron in the vicinity of the electrode. The process of labeling each recorded spike waveform with the identity of its source neuron is called spike sorting and is often approached from an abstracted statistical perspective. However, these approaches do not consider neurophysiological realities and may ignore important features that could improve the accuracy of these methods. Further, standard algorithms typically require selection of at least one free parameter, which can have significant effects on the quality of the output. We describe a Heuristic Spike Sorting Tuner (HSST) that determines the optimal choice of the free parameters for a given spike sorting algorithm based on the neurophysiological qualification of unit isolation and signal discrimination. A set of heuristic metrics are used to score the output of a spike sorting algorithm over a range of free parameters resulting in optimal sorting quality. We demonstrate that these metrics can be used to tune parameters in several spike sorting algorithms. The HSST algorithm shows robustness to variations in signal to noise ratio, number and relative size of units per channel. Moreover, the HSST algorithm is computationally efficient, operates unsupervised, and is parallelizable for batch processing. NEW & NOTEWORTHYHSST incorporates known neurophysiological priors of extracellular neural recordings while simultaneously taking advantage of powerful abstract mathematical tools. Rather than simply selecting free parameters prior to running a sorting algorithm, HSST executes a sorting algorithm across a range of input parameters, using heuristic metrics to detect which spike-sorting output is most physiologically plausible. This novel approach enables unsupervised spike-sorting exceeding the performance of previous methods, thereby enabling the processing of large data sets with confidence.

neuroscience

The effect of wrist posture on extrinsic finger muscle activity during single joint movements

Wrist posture impacts the muscle lengths and moment arms of the extrinsic finger muscles that cross the wrist. As a result, the electromyographic (EMG) activity associated with digit movement at different wrist postures may also change. Therefore, we sought to quantify the posture-dependence of extrinsic finger muscle activity. Fine-wire bipolar electrodes were inserted in the extrinsic hand muscles of able-bodied subjects to record EMG activity during wrist and finger movements in various postures. EMG activity of all the recorded finger muscles were significantly different (p<.05, ANOVA) when performing the same movement in five different wrist postures. EMG activity varied by up to 70%, with the highest levels of activity observed in finger extensors when the wrist was extended. Similarly, finger flexors were most active when the wrist was flexed. For the finger flexors, EMG variations with wrist posture were most prominent for index finger muscles, while the EMG activity of all finger extensor muscles were similarly modulated. The extrinsic finger muscles also showed significant activity during wrist movements with the digits held still regardless of finger posture, suggesting that they may play a role in generating torque during wrist movements. Finally, we developed a pair of generalized classifiers that show that finger muscle EMG can be used to predict wrist posture. These results may impact the design of biomimetic control algorithms for myoelectric prosthetic hands, but further work in transradial amputees is necessary to determine whether this phenomenon persists after amputation.

bioengineering