Search bioRxiv⌕ Search

Biology subjects

Fregly, B. J.

Publications and source records attributed to Fregly, B. J..

11 recordsLinked to original sources

Generic versus personalized foot-ground contact models for predictive simulations of walking: Is personalization worth the effort?

PurposeQuantification of walking function, including joint motions, ground reactions, and joint loads, outside the lab is a growing research area. Because only joint motions can currently be measured outside the lab, researchers are utilizing tracking optimizations of walking to estimate associated ground reactions and inverse dynamic joint loads. However, foot-ground contact models used in such optimizations have been generic rather than personalized, which may limit the accuracy of estimated ground reactions and joint loads. This study compares the predictive capabilities of generic versus personalized foot-ground contact models. MethodsGeneric and personalized foot-ground contact models were evaluated in calibration and tracking optimizations performed using experimental walking data collected from three subjects in varying states of health. Foot-only calibration optimizations evaluated how well both models could reproduce experimental ground reaction and foot motion data while tracking both types of data simultaneously, while whole-body tracking optimizations evaluated how well both models could reproduce experimental ground reactions, joint motion, and joint load data while tracking only experimental joint motion data and achieving dynamic consistency. ResultsFor all three subjects and both types of optimizations, personalized foot-ground contact models reproduced experimental ground reaction, joint motion, and joint load data more accurately than generic foot-ground contact models. ConclusionPersonalized foot-ground contact models can improve the accuracy with which ground reactions and joint loads can be estimated via tracking optimizations of walking using only experimental motion data as inputs. Personalized models require little time and effort to calibrate using freely available software tools and should improve the accuracy of predictive simulations of walking as well.

bioengineering↗

Synergy Feedback Control Predicts Walking Across Multiple Cycles

Neural feedback is important for the control of movement, and multiple neurological disorders (e.g., stroke, cerebral palsy, Parkinsons disease, incomplete spinal cord injury) are characterized by altered neural feedback. Researchers have created numerous computational neuromusculoskeletal models controlled by simulated neural feedback mechanisms, but these models rarely represent actual human subjects and thus have not found practical clinical application. As a step toward designing patient-specific treatments for individuals with neurological disorders, this study used the Neuromusculoskeletal Modeling Pipeline to develop and evaluate a novel synergy-based feedforward (FF)+feedback (FB) control model using a personalized three-dimensional neuromusculoskeletal walking model of an actual human subject post-stroke. Experimental walking data collected from the subject were used to create the subjects personalized walking model. Then for 5 calibration walking cycles, personalized synergy-based FF+FB control models were created. First, the personalized model was used to estimate lower body muscle activations consistent with the subjects electromyographic, joint motion, and joint moment data. Second, five synergy activations per leg with associated synergy vectors were calculated that closely reconstructed the subjects muscle activations and joint moments simultaneously. Third, nominal FF synergy activation controls were calculated by averaging the synergy activations for each leg. Fourth, the nominal FF synergy controls were scaled by 0, 25, 50, 75, 100, and 125%, and the gap in reproducing the subjects muscle activations was filled by fitting FB synergy activation controls as a function of joint positions, velocities, and moments as surrogates for muscle lengths, muscle velocities, and tendon forces. Next for 3 testing walking cycles, the six synergy-based FF+FB models were used to control the subjects personalized walking model in predictive simulations. The 100% FF model (which still had minimal FB) reproduced the testing walking cycles the most closely, and only the 75%, 100%, and 125% FF models predicted near-periodic walking motions using initial conditions consistent with experimental values. The 0, 25, and 50% FF models could generate near-periodic walking motions only when the initial conditions were allowed to diverge substantially from experimental values. Our findings suggest that predictive simulations of walking may require substantial feedforward control when modeling an actual human subject.

bioengineering↗

Reproducible Research: Computational Design of PersonalizedClinical Treatments for Walking Impairments Using the Neuromusculoskeletal Modeling Pipeline

Background: Personalized computational neuromusculoskeletal models have great potential for optimizing the design of clinical treatments for movement impairments. While many software tools address specific parts of the model personalization and treatment optimization processes, they typically require significant programming experience to use and do not cover the full breadth of these two processes. Furthermore, published neuromusculoskeletal modeling studies typically do not provide all the methodological details needed for others to reproduce the work. Consequently, researchers seeking to develop skills in the model personalization and treatment optimization processes face a steep learning curve due to the lack of detailed training materials that demonstrate both processes for real-life clinical problems using real-life subject movement data. Methods: This article presents detailed training tutorials for the model personalization and treatment optimization processes using two real-life clinical problems and the Neuromusculoskeletal Modeling (NMSM) Pipeline. The first clinical problem involves the design of personalized gait modifications and high tibial osteotomy surgery for an individual with bilateral medial knee osteoarthritis, where the goal is to reduce the peak adduction moment in both knees to a specified target level. The second clinical problem involves the design of a synergy-based functional electrical stimulation prescription for an individual post-stroke with impaired walking function, where the goal is to equalize the propulsive and braking impulses between the two legs. Both tutorials were implemented as course projects given to novice users in a combined undergraduate/graduate mechanical engineering course. Results: Both tutorials produced personalized neuromusculoskeletal models and associated dynamically consistent tracking optimizations that closely reproduced subject-specific experimental joint angles, joint moments, ground reaction forces and moments, and (if applicable) muscle activations measured during walking. Subsequent design optimizations predicted personalized treatments that achieved target values of peak knee adduction moments or propulsive and braking impulses. Conclusions: The detailed step-by-step tutorials presented with this article are the first to walk users through the entire process of creating personalized neuromusculoskeletal models and then using them to design personalized treatments for two subjects with two different clinical problems. These tutorials can be used to introduce new users to the NMSM Pipeline and as projects in neuromusculoskeletal modeling courses.

bioengineering↗

Personalization of Closed-Chain Shoulder Models Yields High Kinematic Accuracy for Multiple Motions

The shoulder joint complex is prone to musculoskeletal issues, such as rotator cuff-related pain, which affect two-thirds of adults and often result in suboptimal treatment outcomes. Current musculoskeletal models used to understand shoulder biomechanics are limited by challenges in personalization, inaccuracies in predicting joint and muscle loads, and an inability to simulate anatomically accurate motions. To address these deficiencies, we developed a novel, personalized modeling framework capable of calibrating subject-specific joint centers and functional axes for the shoulder complex. Leveraging in vivo biplane fluoroscopy data and the recent Joint Model Personalization Tool from the Neuromusculoskeletal Modeling Pipeline, we optimized joint parameters and body scale factors for shoulder models with varying degrees of freedom (DOFs). We initially created and tested open-chain scapula-only models (3DOF, 4DOF, and 5DOF) and found that increasing DOFs improved accuracy, with the 5 DOF model yielding the lowest marker distance errors (average = 0.8 mm, maximum = 5.2 mm) as compared to biplane fluorscopy data of the scapula across eight movement trials. We subsequently created closed-chain shoulder models incorporating scapula, clavicle, and humerus bodies. We found closed-chain shoulder models with 5 DOFs for the scapula achieved the highest accuracy (average = 0.9 mm, maximum = 5.7 mm) and showed consistent performance across subjects (n=3) in leave-one-out cross-validation tests (average marker distance errors = 1.0-1.4 mm). This framework minimizes errors in joint kinematics and provides a foundation for future models incorporating personalized musculature and advanced simulations, enhancing its potential clinical utility for rehabilitation and surgical planning.

bioengineering↗

The Neuromusculoskeletal Modeling Pipeline: MATLAB-based Model Personalization and Treatment Optimization Functionality for OpenSim

Neuromusculoskeletal injuries including osteoarthritis, stroke, spinal cord injury, and traumatic brain injury affect roughly 19% of the U.S. adult population. Standardized interventions have produced suboptimal functional outcomes due to the unique treatment needs of each patient. Strides have been made to utilize computational models to develop personalized treatments, but researchers and clinicians have yet to cross the "valley of death" between fundamental research and clinical usefulness. This article introduces the Neuromusculoskeletal Modeling (NMSM) Pipeline, two MATLAB-based toolsets that add Model Personalization and Treatment Optimization functionality to OpenSim. The two toolsets facilitate computational design of individualized treatments for neuromusculoskeletal impairments through the use of personalized neuromusculoskeletal models and predictive simulation. The Model Personalization toolset contains four tools for personalizing 1) joint structure models, 2) muscle-tendon models, 3) neural control models, and 4) foot-ground contact models. The Treatment Optimization toolset contains three tools for predicting and optimizing a patients functional outcome for different treatment options using a patients personalized neuromusculoskeletal model with direct collocation optimal control methods. Support for user-defined cost functions and model modification functions facilitate simulation of a vast number of possible treatments. An NMSM Pipeline use case is presented for an individual post-stroke with impaired walking function, where the goal was to predict how the subjects neural control could be changed to improve walking speed without increasing metabolic cost. First the Model Personalization toolset was used to develop a personalized neuromusculoskeletal model of the subject starting from a generic OpenSim full- body model and experimental walking data (video motion capture, ground reaction, and electromyography) collected from the subject at his self-selected speed. Next the Treatment Optimization toolset was used with the personalized model to predict how the subject could recruit existing muscle synergies more effectively to reduce muscle activation disparities between the paretic and non-paretic legs. The software predicted that the subject could increase his walking speed by 60% without increasing his metabolic cost per unit time by modifying existing muscle synergy recruitment. This hypothetical treatment demonstrates how NMSM Pipeline tools could allow researchers working collaboratively with clinicians to develop personalized neuromusculoskeletal models of individual patients and to perform predictive simulations for the purpose of designing personalized treatments that maximize a patients post-treatment functional outcome.

bioengineering↗

Comparison of Synergy Extrapolation and Static Optimization for Estimating Multiple Unmeasured Muscle Activations during Walking

BackgroundCalibrated electromyography (EMG)-driven musculoskeletal models can provide great insight into internal quantities (e.g., muscle forces) that are difficult or impossible to measure experimentally. However, the need for EMG data from all involved muscles presents a significant barrier to the widespread application of EMG-driven modeling methods. Synergy extrapolation (SynX) is a computational method that can estimate a single missing EMG signal with reasonable accuracy during the EMG-driven model calibration process, yet its performance in estimating a larger number of missing EMG signals remains unclear. MethodsThis study assessed the accuracy with which SynX can use eight measured EMG signals to estimate muscle activations and forces associated with eight missing EMG signals in the same leg during walking while simultaneously performing EMG-driven model calibration. Experimental gait data collected from two individuals post-stroke, including 16 channels of EMG data per leg, were used to calibrate an EMG-driven musculoskeletal model, providing "gold standard" muscle activations and forces for evaluation purposes. SynX was then used to predict the muscle activations and forces associated with the eight missing EMG signals while simultaneously calibrating EMG-driven model parameter values. Due to its widespread use, static optimization (SO) was also utilized to estimate the same muscle activations and forces. Estimation accuracy for SynX and SO was evaluated using root mean square errors (RMSE) to quantify amplitude errors and correlation coefficient r values to quantify shape similarity, each calculated with respect to "gold standard" muscle activations and forces. ResultsOn average, SynX produced significantly more accurate amplitude and shape estimates for unmeasured muscle activations (RMSE 0.08 vs. 0.15, r value 0.55 vs. 0.12) and forces (RMSE 101.3 N vs. 174.4 N, r value 0.53 vs. 0.07) compared to SO. SynX yielded calibrated Hill-type muscle-tendon model parameter values for all muscles and activation dynamics model parameter values for measured muscles that were similar to "gold standard" calibrated model parameter values. ConclusionsThese findings suggest that SynX could make it possible to calibrate EMG-driven musculoskeletal models for all important lower-extremity muscles with as few as eight carefully chosen EMG signals and eventually contribute to the design of personalized rehabilitation and surgical interventions for mobility impairments.

biophysics↗

Changes in Walking Function and Neural Control following Pelvic Cancer Surgery with Reconstruction

Surgical planning and custom prosthesis design for pelvic cancer patients is challenging due to the unique clinical characteristics of each patient and the significant amount of pelvic bone and hip musculature often removed. Limb-sparing internal hemipelvectomy surgery with custom prosthesis reconstruction has become a viable option for this patient population. However, little is known about how post-surgery walking function and neural control change from pre-surgery conditions. This case study combined comprehensive human movement data collection with personalized neuromusculoskeletal computer modeling to provide a thorough assessment of pre-to post-surgery changes in walking function and neural control for a single pelvic sarcoma patient who received internal hemipelvectomy surgery with custom prosthesis reconstruction. Extensive walking data (video motion capture, ground reaction, and EMG) were collected from the patient before surgery and after plateau in recovery after surgery. Pre- and post-surgery personalized neuromusculoskeletal computer models of the patient were then constructed using the patients pre- and post-surgery walking data. These models were used to calculate the patients pre- and post-surgery joint motions, joint moments, and muscle synergies. The calculated muscle synergies were described by time-invariant synergy vectors and time-varying synergy activations, were consistent with the patients experimental EMG data, and produced the patients experimental joint moments found via inverse dynamics. The patients post-surgery walking function was marked by a slower self-selected walking speed coupled with several compensatory mechanisms necessitated by lost or impaired hip muscle function, while the patients post-surgery neural control demonstrated a dramatic change in coordination strategy (as evidenced by modified synergy vectors) with little change in recruitment timing (as evidenced by conserved synergy activations). Furthermore, the patients post-surgery muscle activations were fitted accurately using the patients pre-surgery synergy activations but poorly using the patients pre-surgery synergy vectors. These results provide valuable information about which aspects of post-surgery walking function could potentially be improved through modifications to surgical decisions, custom prosthesis design, or rehabilitation protocol, as well as how computational simulations could be formulated to predict post-surgery walking function reliably given a patients pre-surgery walking data and the planned surgical decisions and custom prosthesis design.

bioengineering↗

Evaluation of Synergy Extrapolation for Predicting Unmeasured Muscle Excitations from Measured Muscle Synergies

Electromyography (EMG)-driven musculoskeletal modeling relies on high-quality measurements of muscle electrical activity to estimate muscle forces. However, a critical challenge for practical deployment of this approach is missing EMG data from muscles that contribute substantially to joint moments. This situation may arise due to either the inability to measure deep muscles with surface electrodes or the lack of a sufficient number of EMG electrodes. Muscle synergy analysis is a dimensionality-reduction approach to decompose a large number of muscle excitations into a small number of time-varying synergy excitations along with time-invariant synergy weights that define the contribution of each corresponding synergy excitation to a specific muscle excitation. This study evaluates how accurately missing muscle excitations can be predicted using synergy excitations extracted from muscles with available EMGs (henceforth called "synergy extrapolation"). The results were reported on a gait dataset collected from a stroke survivor walking on an instrumented treadmill at self-selected and fastest-comfortable speeds. The evaluation process started with full calibration of a lower-body EMG-driven model using 16-channel EMGs (including surface and indwelling) in each leg. One indwelling EMG (either iliopsoas or adductor longus) was then treated as unmeasured at a time. The synergy weights associated with the unmeasured muscle were predicted through solving a nonlinear optimization problem where the errors between inverse dynamics and EMG-driven joint moments were minimized. We also quantitatively evaluated how synergy analysis algorithms (principal component analysis (PCA) and non-negative matrix factorization (NMF)), EMG normalization methods, and number of synergies affect the accuracy of the predicted unmeasured muscle excitation. Synergy extrapolation performance was most influenced by the choice of synergy analysis algorithm and number of synergies. PCA with 5 or 6 synergies consistently predicted unmeasured muscle excitations most accurately and with greatest robustness to choice of EMG normalization method. Furthermore, the associated joint moment matching accuracy was comparable to that produced by the full EMG-driven calibration. The synergy extrapolation method described in this study may facilitate the assessment of human neuromuscular control and biomechanics in response to surgical or rehabilitation treatment when important EMG signals are missing.

bioengineering↗

Musculoskeletal Model Personalization Affects Metabolic Cost Estimates for Walking

Assessment of metabolic energy cost as a metric for human performance has expanded across various fields within the scientific, clinical, and engineering communities. As an alternative to measuring metabolic cost experimentally, musculoskeletal models incorporating metabolic cost models have been developed. However, to utilize these models for practical applications, the accuracy of their metabolic cost predictions requires improvement. Previous studies have reported the benefits of using personalized musculoskeletal models for various applications, yet no study has evaluated how model personalization affects metabolic cost estimation. This study investigated the effect of musculoskeletal model personalization on estimates of metabolic cost of transport (CoT) during post-stroke walking using three commonly used metabolic cost models. We analyzed data previously collected from two male stroke survivors with right-sided hemiparesis. The three metabolic cost models were implemented within three musculoskeletal modeling approaches involving different levels of personalization. The first approach used a scaled generic OpenSim model and found muscle activations via static optimization (SOGen). The second approach used a personalized EMG-driven musculoskeletal model with personalized functional axes but found muscle activations via static optimization (SOCal). The third approach used the same personalized EMG-driven model but calculated muscle activations directly from EMG data (EMGCal). For each approach, the muscle activation estimates were used to calculate each subjects cost of transport (CoT) at different gait speeds using three metabolic cost models (Umberger 2003, Umberger 2010, and Bhargava 2004). The calculated CoT values were compared with published CoT trends as a function of stance time, double support time, step positions, walking speed, and severity of motor impairment (i.e., Fugl-Meyer score). Overall, U10-SOCal, U10-EMGCal, U03-SOCal, and U03-EMGCal were able to produce slopes between CoT and the different measures of walking asymmetry that were statistically similar to those found in the literature. Although model personalization seemed to improve CoT estimates, further tuning of parameters associated with the different metabolic cost models in future studies may allow for realistic CoT predictions. An improvement in CoT predictions may allow researchers to predict human performance, surgical, and rehabilitation outcomes reliably using computational simulations.

bioengineering↗

How Well Do Commonly Used Co-Contraction Indices Approximate Lower Limb Joint Stiffness Trends during Gait?

Muscle co-contraction generates joint stiffness to improve stability and accuracy during limb movement but at the expense of higher energetic cost. The quantification of joint stiffness generated from muscle co-contraction is difficult through both experimental and computational means for its benefit and cost to be assessed. Quantification of muscle co-contraction may offer an alternative path for estimating joint stiffness. By choosing the commonly used Co-Contraction Indices (CCIs) to represent muscle co-contraction, this study investigated the feasibility of using CCI to approximate lower limb joint stiffness trends during gait. A calibrated EMG-driven musculoskeletal model of a hemiparetic individual post-stroke from a previous study was used to generate the quantities required for CCI calculation and model-based estimation of joint stiffness. A total of 14 classes of CCIs for various combinations of antagonistic muscle pairs were calculated based on two common CCI formulations, each with 7 types of quantities that included variations of electromyography (EMG) signals and joint moments from the muscles. Correlations between CCIs and model-based estimates of sagittal plane stiffness of the lower extremity joints (hip, knee, ankle) were computed. Although moderate to strong correlation was observed between some CCI formulations and the corresponding joint stiffness, these associations were highly dependent on the methodological choices made for CCI computation. The overall findings of this study were the following: (1) the formulation proposed by Rudolph et al. (2000), CCI1, was more correlated with joint stiffness than that of Falconer and Winter (1985); (2) Moment-based CCI1 from individual antagonistic muscle pairs was more correlated than EMG-based CCI1; (3) EMG signals with calibrated electromechanical delay and joint moment generated by individual muscle without normalization to a reference value were the most correlated for EMG-based CCI1 and moment-based CCI1, respectively. The combination of antagonistic muscle pairs for most correlated within each CCI class was also identified. By using CCI to approximate joint stiffness trends, this study may open an alternative path to studying joint stiffness.

bioengineering↗

DO MUSCLE SYNERGIES IMPROVE OPTIMIZATION PREDICTION OF MUSCLE ACTIVATIONS DURING GAIT?

Determination of muscle forces during motion can help to understand motor control, assess pathological movement, diagnose neuromuscular disorders, or estimate joint loads. Difficulty of in vivo measurement made computational analysis become a common alternative in which, as several muscles serve each degree of freedom, the muscle redundancy problem must be solved. Unlike static optimization (SO), synergy optimization (SynO) couples muscle activations across all time frames, thereby altering estimated muscle co-contraction. This study explores whether the use of a muscle synergy structure within a static optimization framework improves prediction of muscle activations during walking. A motion/force/EMG gait analysis was performed on five healthy subjects. A musculoskeletal model of the right leg actuated by 43 Hill-type muscles was scaled to each subject and used to calculate joint moments, muscle-tendon kinematics and moment arms. Muscle activations were then estimated using SynO with two to six synergies and traditional SO, and these estimates were compared with EMG measurements. SynO neither improved SO prediction of experimental activation patterns nor provided SO exact matching of joint moments. Finally, synergy analysis was performed on SO estimated activations, being found that the reconstructed activations produced poor matching of experimental activations and joint moments. As conclusion, it can be said that, although SynO did not improve prediction of muscle activations during gait, its reduced dimensional control space could be beneficial for applications such as functional electrical stimulation (FES) or motion control and prediction.

neuroscience↗