Search bioRxiv⌕ Search

Biology subjects

Fort, K. L.

Publications and source records attributed to Fort, K. L..

6 recordsLinked to original sources

Orbitrap Collision Cross Section Measurements Enhance Isomer Annotations in Lipidomics

Despite advances in high-resolution mass spectrometry (HRMS), confident lipid annotation remains challenging due to the extensive chemical diversity of the lipidome and the prevalence of isomeric species. Ion mobility collision cross section (CCS) measurements provide structural information that complements HRMS; however, not all HRMS platforms can perform these measurements, necessitating a trade-off among mass resolution, accuracy, and robustness. Here, we introduce a method to infer lipid CCS values directly from liquid chromatography (LC)-Orbitrap MS experiments (OrbiCCS). We show that Orbitrap mass analyzer pressure readings, and therefore CCS values, are influenced by the LC gradient solvent composition, requiring correction using isotopically labeled internal standards injected post-column. We also show that hundreds of lipid features can be assigned OrbiCCS values in a single LC run, with average precision better than 1% and an accuracy of 1-2% relative to reference DTCCS and TIMSCCS values. This excellent CCS accuracy not only enables more reliable annotation of lipid species in complex mixtures by matching OrbiCCS values to reference databases but also accelerates lipid structural elucidation based on the unknowns position in OrbiCCS-retention time-m/z space.

biochemistry↗

Full Scan enhanced Dynamic Range MS improves metabolite coverage and cancer cell-line discrimination in untargeted metabolomics

Metabolite detection with mass spectrometry (MS) in untargeted metabolomics is limited by the wide concentration range of metabolites, where high-abundance signals dominate MS1 scans and suppress detection of low-abundance features. This reduces metabolite coverage and obscures biologically relevant signals, particularly in complex cellular systems. Full Scan enhanced Dynamic Range (eDR) MS addresses these limitations by partitioning the MS1 mass range into multiple subscans and mass windows, reducing saturation effects from dominant ions. Here, we systematically evaluate different eDR acquisition strategies for untargeted metabolomics. Across four hepatocellular carcinoma cell lines, Full Scan eDR MS increased detectable features up to [~]3.5-fold compared to Full Scan MS. Among equidistant window configurations, 12 windows yielded the highest feature count and broadest dynamic range, while custom window distributions further improved detection in ion-dense regions. In particular, allocating smaller window sizes to the low m/z region selectively increased detection of low-mass features while preserving performance for higher mass ions. Full Scan eDR MS also improved data quality, reducing variation and increasing signal-to-noise ratios, especially for low-abundance metabolites. MS2 coverage and metabolite identifications increased substantially, resulting in unique detection of cancer-relevant metabolites. Importantly, the increased depth of metabolite detection enabled improved discrimination between cancer cell lines, supporting deeper interrogation of metabolic heterogeneity. Overall, these results establish Full Scan eDR MS as a flexible strategy to improve sensitivity and metabolome coverage in untargeted metabolomics. Customization of window size and distribution enable targeted expansion of dynamic range within predefined mass regions, allowing MS acquisition to be tailored to sample complexity and metabolites of interest.

biochemistry↗

Higher-Throughput Proteome Profiling Enabled by Parallelized Pre-Accumulation and Optimized Ion Processing in the Orbitrap Astral Zoom Mass Spectrometer

High-throughput proteomics is critical for understanding biological processes, enabling large-scale studies such as biomarker discovery and systems biology. However, current mass spectrometry technologies face limitations in speed, sensitivity, and scalability for analyzing large sample cohorts. The Thermo Scientific Orbitrap Astral Zoom mass spectrometer (MS) was developed to address these limitations by improving acquisition speed, ion utilization, and spectral processing, which are all essential for advancing proteome depth in high-throughput proteomics. The Orbitrap Astral Zoom MS achieves ultra-fast MS/MS scan rates of up to 270 Hz with enhanced ion utilization through pre-accumulation, enabling the identification of [~]100,000 unique peptides and >8,400 proteins in a single 300 samples-per-day (SPD) analysis of human cell lysate. The optimized system reduces analysis time by 40%, achieves near-complete proteome coverage (>12,000 proteins) in 2.7 hours, and enables ultra-high-throughput workflows, identifying >7,000 proteins in a 500 SPD method with exceptional reproducibility (Pairwise Pearson correlations >0.99). These advancements establish the Orbitrap Astral Zoom MS as a new benchmark in proteomics, significantly enhancing speed, sensitivity, and scalability, paving the way for routine large-scale proteome studies with applications in clinical research and systems biology. TeaserHigh-Speed Human Proteome Analysis using the Orbitrap Astral Zoom Mass Spectrometer

biochemistry↗

Enhancing tandem MS sensitivity and peptide identification via ion pre-accumulation in an Orbitrap mass spectrometer

High-throughput mass spectrometry-based proteomics has gained increasing interest for both academic and industrial applications. As implementation of faster gradients has facilitated higher sample throughput, mass spectrometers must adapt to shorter analysis times by enhancing scanning speed and sensitivity. For Orbitrap mass spectrometers, faster scan rates are constrained by the need for sufficient ion accumulation time, particularly given limitations on duty cycle at high repetition rate, and transient length, which determines analyzer sensitivity and resolving power. In this context, implementing alternative ion scheduling and better ion signal-processing strategies are needed to unleash the speed of these instruments. Here, we introduce a new scanning strategy termed pre-accumulation, which enables the storage of ions in the bent flatapole in parallel to the operation of the C-trap/IRM, leading to a significant improvement in ion beam utilization and enabling for the first time scanning speeds of >70 Hz on hybrid Orbitrap instruments. The combination of pre-accumulation and increased scan speeds notably enhances peptide and protein group identifications for short LC gradients and improves sensitivity for high-throughput applications. These benefits were further amplified when coupled with the full mass range phase-constrained spectrum deconvolution method ({Phi}SDM), especially for fast, lower-resolving Orbitrap measurements used with short LC gradients. Overall, we demonstrate that pre-accumulation of ions in the bent flatapole offers distinct advantages, particularly for conditions with reduced signal input. Since no hardware changes are required, this approach is highly attractive for Orbitrap mass spectrometers operated with fast MS/MS acquisition methods.

biochemistry↗

To 200,000 m/z and beyond: native electron capture charge reduction mass spectrometry deconvolves heterogeneous signals in large biopharmaceutical analytes

Great progress has been made in the detection of large biomolecular analytes by native mass spectrometry, however characterizing highly heterogeneous samples remains challenging due to the presence of many overlapping signals from complex ion distributions. Electron-capture charge reduction (ECCR), in which a protein cation captures free electrons without apparent dissociation, can dealign overlapping signals by shifting the ions to lower charge states. The concomitant shift to higher m/z also facilitates the exploration of instrument upper m/z limits if large complexes are used. Here we perform native ECCR on the bacterial chaperonin GroEL and megadalton scale adeno-associated virus (AAV) capsid assemblies on the Q Exactive UHMR mass spectrometer. Charge reduction of AAV8 capsids by up to 90% pushes signals well above 100,000 m/z and enables charge state resolution and mean mass determination of these highly heterogeneous samples, even for capsids loaded with genetic cargo. With minor instrument modifications the UHMR can detect charge reduced ion signals beyond 200,000 m/z. This work demonstrates the utility of ECCR for deconvolving heterogeneous signals in native mass spectrometry and presents the highest m/z signals ever recorded on an Orbitrap instrument, opening up the use of Orbitrap native mass spectrometry for heavier analytes than ever before.

molecular biology↗

Frequency chasing of individual megadalton ions in an Orbitrap analyzer improves precision of analysis in single molecule mass spectrometry

To enhance the performance of charge detection mass spectrometry, we investigated the behavior of macromolecular single ions on their paths towards and within the Orbitrap analyzer. We discovered that ions in mass beyond one megadalton reach a plateau of stability and can be successfully trapped for seconds, travelling a path length of multiple kilometers, thereby enabling precise mass analysis with an effective resolution of greater than 100,000 at m/z 35,000. Through monitoring the frequency of individual ions, we show that these high mass ions, rather than being lost from the trap, can gradually lose residual solvent molecules and, in rare cases, a single elementary charge. Our observations highlight the importance of efficient desolvation for optimal charge detection mass spectrometry and inspired us to implement multiple improved data acquisition strategies. We demonstrate that the frequency drift of single ions due to desolvation and charge stripping can be corrected, which improves the effective ion sampling 23-fold and gives a two-fold improvement in mass precision and resolution, as demonstrated in the analysis of various viral particles.

biophysics↗