Search bioRxiv⌕ Search

Biology subjects

Folland, J. P.

Publications and source records attributed to Folland, J. P..

5 recordsLinked to original sources

The heterogeneity of age-related muscle atrophy of lower limb muscles

Age-related skeletal muscle atrophy differs between upper and lower body muscles and may also differ between lower limb muscles, but these muscle-specific patterns remain poorly characterised. We acquired axial 3T magnetic resonance images from sex-balanced samples of thirty young (24+/-4 years) and thirty older adults (73+/-4 years). Muscle volume of seventeen lower limb muscles/compartments was quantified using manual segmentation and expressed as absolute volume, relative to body mass, and as a percentage of total muscle volume. Absolute muscle volume was lower in older adults in 13 out of 17 muscles compared to young, with substantial heterogeneity in the effect sizes (d=0.01-3.36). Age group * muscle interaction contrasts revealed muscle-specific age-related differences in volume. Three of the quadriceps muscles demonstrated greater age-related atrophy compared to several other muscles (e.g. vastus lateralis differing from 14 of the other 16 muscles; d[≥]1.54). Conversely, the anterior and deep posterior compartments of the shank and biceps femoris short head showed significantly smaller age-related atrophy than several other muscles. These interaction effects were exacerbated when expressed in relative terms. Consequently, three of four shank compartments, gluteus maximus and adductor magnus represented a greater proportion of total muscle volume in older adults, whereas the vastus lateralis, vastus intermedius, rectus femoris, semitendinosus, gracilis, and iliopsoas contributed a smaller proportion in older adults. These findings highlight the variability in age-related leg muscle atrophy in a large mixed sex cohort, resulting in a redistribution of muscle volume in the lower limb.

physiology↗

Motor unit discharge properties of the vastii muscles and their modulation with contraction level depend on the knee-joint angle

This study examined the effect of the knee-joint angle on motor unit (MU) discharge properties of the vastii muscles and their modulation with contraction level. Twelve young adults performed unilateral isometric knee-extension contractions during three experimental sessions at either 25, 55, and 85{degrees} of knee flexion (full extension: 0{degrees}) in a randomised order. Each session involved maximal voluntary contractions (MVCs) followed by submaximal trapezoidal and triangular contractions at different levels relative to maximal voluntary torque (MVT). High-density surface electromyograms were recorded from vastus lateralis and medialis muscles and, subsequently, decomposed to obtain discharge timings of individual MUs. MVT was the greatest, whereas MU discharge rate (DR) during MVCs and submaximal contraction levels ([≥]30% MVT) was the lowest at the intermediate joint angle (55{degrees}). The highest DR during MVCs and high-level contractions (70% MVT), however, was at the most flexed knee position (85{degrees}), which was due to a greater DR increase 50-70% MVT compared to 25{degrees} and 55{degrees}. The onset-offset DR hysteresis ({Delta}F), an estimate of persistent inward current contribution to motoneuron discharge, decreased with knee flexion and increased with contraction level, whereas the degree of motoneuron input-output nonlinearity (brace height) did not vary with joint angle but decreased with contraction level. At 85{degrees}, {Delta}F increased more and brace height decreased less with contraction level compared to 25{degrees} and 55{degrees}. These findings indicate that vastii MU DR and its modulation with contraction level vary with knee-joint angle, which could be partly explained by the modulation of motoneuron intrinsic electrical properties. NEW & NOTEWORTHYThis study explored the relationship between motoneuron output to the vastii muscles at different knee-joint angles (quadriceps lengths) and isometric contraction levels. We showed that the motor unit discharge rate was lowest at the angle of the greatest absolute torque capacity, whereas the contraction-level-induced increases in discharge rate and motoneuron excitability were the greatest in the flexed position. These findings suggest that joint-angle-dependent adjustments in sensory feedback modulate motor control of the knee-extensor muscles.

physiology↗

Non-invasive muscle biopsy: estimation of muscle fibre size from a neuromuscular interface

Because of the biophysical relation between muscle fibre diameter and the propagation velocity of action potentials along the muscle fibres, motor unit conduction velocity (MUCV) could be a non-invasive index of muscle fibre size in humans. However, the relation between MUCV and fibre size has been only assessed indirectly in animal models and in human patients with invasive intramuscular EMG recordings, or it has been mathematically derived from computer simulations. By combining advanced non-invasive techniques to record motor unit activity in vivo, i.e., high-density surface EMG, with the gold standard technique for muscle tissue sampling, i.e., muscle biopsy, here we investigated the relation between the conduction velocity of populations of motor units identified from the biceps brachii muscle, and muscle fibre diameter. Moreover, we demonstrate the possibility to predict muscle fibre diameter (R2 = 0.66) and cross-sectional area (R2 = 0.65) from conduction velocity estimates with low systematic bias (~2% and ~4% respectively) and a relatively low margin of individual error (~8% and ~16%, respectively). The proposed neuromuscular interface opens new perspectives in the use of high-density EMG as a non-invasive tool to estimate muscle fibre size without the need of surgical biopsy sampling. The non-invasive nature of high-density surface EMG for the assessment of muscle fibre size may be useful in studies monitoring child development, aging, space and exercise physiology. SIGNIFICANCE STATEMENTOur study explored the relation between the conduction velocity of populations of motor units and muscle fibre size in healthy humans. Our results provide in vivo evidence that a high-density surface EMG-derived physiological parameter, i.e. motor unit conduction velocity, can be adopted to estimate muscle fibre size, without the need of surgical biopsy sampling. Here we propose a neuromuscular interface that opens new perspectives not only in the study of neuromuscular disorders, but also in other fields where the non-invasive and painless determination of muscle fibre and motor unit size becomes a priority, such as in aging, space and exercise physiology.

physiology↗

Neural decoding from surface high-density EMG signals: influence of anatomy and synchronization on the number of identified motor units

ObjectiveHigh-density surface electromyography (HD-sEMG) allows the reliable identification of individual motor unit (MU) action potentials. Despite the accuracy in decomposition, there is a large variability in the number of identified MUs across individuals and exerted forces. Here we present a systematic investigation of the anatomical and neural factors that determine this variability. ApproachWe investigated factors of influence on HD-sEMG decomposition, such as synchronization of MU discharges, distribution of MU territories, muscle-electrode distance (MED - subcutaneous fat thickness), maximum anatomical cross-sectional area (ACSAmax), and fiber CSA. For this purpose, we recorded HD-sEMG signals, ultrasound, magnetic resonance imaging, and muscle biopsy of the biceps brachii muscle from two groups of participants - untrained-controls (UT=14) and strength-trained (>3 years of training, ST=16) - while they performed isometric ramp contractions with elbow flexors (at 15, 35, 50 and 70% maximum voluntary torque - MVT). We assessed the correlation between the number of accurately detected MUs by HD-sEMG decomposition and each measured parameter, for each target force level. Multiple regression analysis was then applied. Main resultsST subjects showed lower MED (UT: 4.8 {+/-} 1.4 vs. ST: 3.7 {+/-} 0.8 mm) associated to a greater number of identified motor units (UT: 21.3 {+/-} 10.2 vs. ST: 29.2 {+/-} 11.8 MUs/subject). Both groups showed a negative correlation between MED and the number of identified MUs at low forces (r= -0.6, p=0.002 at 15% MVT). Moreover, the number of identified MUs was positively correlated to the distribution of MU territories (r=0.56, p=0.01) and ACSAmax (r=0.48, p=0.03) at 15% MVT. By accounting for all anatomical parameters, we were able to partly predict the number of decomposed MUs at low but not at high forces. SignificanceOur results confirmed the influence of subcutaneous tissue on the quality of HD-sEMG signals and demonstrated that MU spatial distribution and ACSAmax are also relevant parameters of influence for current decomposition algorithms.

bioengineering↗

Reticulospinal drive increases maximal motoneuron output in humans

Maximal rate of force development in adult humans is determined by the maximal motoneuron output, however the origin of the underlying synaptic inputs remains unclear. Here, we tested a hypothesis that the maximal motoneuron output will increase in response to a startling cue, a stimulus that purportedly activates the pontomedullary reticular formation neurons that make mono- and disynaptic connections to motoneurons via fast-conducting axons. Twenty-two men were required to produce isometric knee extensor forces "as fast and as hard" as possible from rest to 75% of maximal voluntary force, in response to visual (VC), visual-auditory (VAC), or visual-startling cue (VSC). Motoneuron activity was estimated via decomposition of high-density surface electromyogram recordings over the vastus lateralis and medialis muscles. Reaction time was significantly shorter in response to VSC compared to VAC and VC (i.e., the StartReact effect). The VSC further elicited faster neuromechanical responses including a greater number of discharges per motor unit per second and greater maximal rate of force development, with no differences between VAC and VC. We provide evidence, for the first time, that the synaptic input to motoneurons increases in response to a startling cue, suggesting a contribution of subcortical pathways to maximal motoneuron output in humans, likely originating from the pontomedullary reticular formation.

physiology↗