5 recordsLinked to original sources

Constitutive discovery in the living human heart

Constitutive models of myocardial mechanics form a cornerstone of personalized cardiac simulations and cardiac digital twins. Researchers traditionally prescribe these models a priori and calibrate them from ex vivo tissue experiments, even though tissue excision alters loading conditions, removes residual stresses, and eliminates important physiological interactions. Multimodal cardiac MRI now provides subject-specific ventricular geometry, deformation, and myocardial microstructure, yet current inverse approaches still rely on predefined constitutive laws. Here we present the first framework to discover constitutive models of passive myocardial mechanics directly from in vivo cardiac imaging data by embedding a constitutive artificial neural network within a nonlinear finite element model of ventricular filling. Using multimodal cardiac MRI that combines ventricular geometry, deformation, and microstructure from a representative healthy individual, the framework identifies sparse, mechanically admissible strain-energy functions without prescribing their form a priori. The best-performing model contains only two fiber- and two sheet-invariant terms, achieves a mean displacement error of 1.62 mm, and reduces the error of the widely used Guccione and Holzapfel models by 34.14% and 26.01%. The discovered models indicate that fiber- and sheet-related anisotropic mechanisms dominate the passive mechanical response during physiological ventricular filling. More broadly, this work establishes a non-invasive strategy for subject-specific constitutive discovery from cardiac imaging data and lays the foundation for personalized cardiac simulations and cardiac digital twins.

bioengineering↗

Personalized biventricular mechanics and sensitivity to model morphology

AO_SCPLOWBSTRACTC_SCPLOWWe present a computational framework for constructing patient-specific models of cardiac mechanics based on standard clinical data, including electrocardiogram (ECG), cuff blood pressure, and electrocardiography-gated computed tomography angiography (CTA) imaging. The model is coupled to a closed-loop lumped parameter network (LPN) circulatory model and incorporates rule-based fiber architecture, as well as spatially varying epicardial boundary conditions to approximate surrounding tissue support. Model parameters are personalized through a multistep procedure that sequentially tunes circulatory dynamics, passive mechanics, and active contraction. The resulting personalized BiV model closely matches clinical pressure and volume measurements and reasonably agrees with image-based myocardial deformation. To assess the impact of anatomical model choice, we compare the BiV model to two commonly-used simplifications: a truncated BiV (t-BiV) model cut at the basal plane and a left ventricle-only (LV) model. For these models, we also evaluate their sensitivity to plausible variations in boundary conditions and contractile strength. With all other inputs held fixed, the LV model exhibits similar global pressure/volume behavior, despite moderate differences in regional deformation. In contrast, the t-BiV model produces substantial differences in both global function and local myocardial mechanics. These results suggest that while LV-only models may be sufficient for biomechanical studies, truncation at the basal plane strongly impacts model outputs and should be used with caution.

bioengineering↗

Assessing the Impact of Valve Sizing and Orientation on Bioprosthetic Pulmonary Valve Hemodynamics Using In Vitro 4D-Flow MRI

PurposePulmonary valve replacement (PVR) using bioprosthetic valves is a common procedure performed in patients with repaired Tetralogy of Fallot and other conditions, but these valves frequently become dysfunctional within 15 years of implantation. Since PVR is often performed in adolescence, valves are typically oversized to account for somatic growth. However, the contribution of oversizing to early valve failure are not clearly understood. The purpose of this study was to explore the impact of valve sizing and orientation on local hemodynamics and valve performance. MethodsDifferent valve sizes were represented by changing the cardiac output through a 25 mm bioprosthetic valve implanted in an idealized 3D-printed model of the right ventricular outflow tract (RVOT). The local hemodynamics at three valve sizes and two valve orientations were assessed using 4D-Flow MRI and high-speed camera imaging. ResultsNoticeable differences in jet asymmetry, the amount of recirculation, leaflet opening patterns, as well as the size and location of reversed flow regions were observed with varying valve sizes. Rotation of the valve resulted in drastic differences in reversed flow regions, but not forward flow. ConclusionFlow features observed in the oversized valve in this study have previously been correlated with calcification, hemolysis, and leaflet fatigue. Therefore, valve oversizing can negatively impact local hemodynamics and leaflet performance.

bioengineering↗

Hemodynamics in Patients with Aortic Coarctation: A Comparison of in vivo 4D-Flow MRI and FSI Simulation

The analysis of quantitative hemodynamics provides information for the diagnosis and treatment planning in patients with aortic coarctation (CoA). Patient-specific computational fluid dynamics (CFD) simulations reveal detailed hemodynamic information, but their agreement with the clinical standard 4D-Flow magnetic resonance imaging (MRI) needs to be characterized. This work directly compares in vivo CFD fluid-structure interaction (FSI) simulations against 4D-Flow MRI in patients with CoA (N=5). 4D-Flow MRI-derived flow waveforms and cuff blood pressure measurements were used to tune the boundary conditions for the FSI simulations. Flow rates from 4D-Flow MRI and FSI were compared at cross-sections in the ascending aorta (AAo), CoA and descending aorta (DAo). Qualitative comparisons showed an overall agreement of flow patterns in the aorta between the two methods. The R2 values for the flow waveforms in the AAo, CoA, and DAo were 0.97, 0.84 and 0.81 respectively, representing a strong correlation between 4DFlow MRI measurements and FSI results. This work characterizes the use of patient-specific FSI simulations in quantifying and analyzing CoA hemodynamics to inform CoA treatment planning.

bioengineering↗

A Framework for Evaluating Myocardial Stiffness Using 3D-Printed Hearts

MRI-driven computational modeling is increasingly used to simulate in vivo cardiac mechanical behavior and estimate subject-specific myocardial stiffness. However, in vivo validation of these estimates is exceedingly difficult due to the lack of a known ground-truth in vivo myocardial stiffness. We have developed 3D-printed heart phantoms of known myocardium-mimicking stiffness and MRI relaxation properties and incorporated the heart phantoms within a highly controlled MRI-compatible setup to simulate in vivo diastolic filling. The setup enables the acquisition of experimental data needed to evaluate myocardial stiffness using computational constitutive modeling: phantom geometry, loading pressures, boundary conditions, and filling strains. The pressure-volume relationship obtained from the phantom setup was used to calibrate an in silico model of the heart phantom undergoing simulated diastolic filling. The model estimated stiffness was compared with ground-truth stiffness obtained from uniaxial tensile testing. Ultimately, the setup is designed to enable extensive validation of MRI and FEM-based myocardial stiffness estimation frameworks.

bioengineering↗