Long-Term Performance of Utah Slanted Electrode Arrays and Intramuscular Electromyographic Leads Implanted Chronically in Human Arm Nerves and Muscles

ObjectiveWe explore the long-term performance and stability of seven percutanous Utah Slanted Electrode Arrays (USEAs) and intramuscular recording leads (iEMGs) implanted chronically in the residual arm nerves and muscles of three human amputees as a means to permanently restore sensorimotor function after upper-limb. ApproachWe quantify the number of functional recording and functional stimulating electrodes over time. We also calculate the signal-to-noise ratio of USEA and iEMG recordings and quantify the stimulation amplitude necessary to evoke detectable sensory percepts. Furthermore, we quantify the consistency of the sensory modality, receptive field location, and receptive field size of USEA-evoked percepts. Main ResultsIn the most recent subject, involving USEAs with technical improvements, neural recordings persisted for 502 days (entire implant duration) and the number of functional recording electrodes for one USEA increased over time. However, for six out of seven USEAs the number of functional recording electrodes decreased within the first two months after implantation. The signal-to-noise ratio of neural recordings and electromyographic recordings stayed relatively consistent over time. Sensory percepts were consistently evoked over the span of 14 months, were not significantly different in size, and highlighted the nerves fascicular organization. The percentage of percepts with consistent modality or consistent receptive field location between sessions (~1 month apart) varied between 0-86.2% and 9.1-100%, respectively. Stimulation thresholds and electrode impedances increased initially but then remained relatively stable over time. SignificanceThis work demonstrates improved performance of USEAs, and provides a basis for comparing the longevity and stability of USEAs to that of other neural interfaces. Although USEAs provide a rich repertoire of neural recordings and sensory percepts, performance still generally declines over time. Future work should leverage the results presented here to further improve USEA design or to develop adaptive algorithms that can maintain a high level of performance.

neuroscience↗

An Adaptable Prosthetic Wrist Reduces Subjective Workload

Many presently available prostheses lack a functional wrist. To fill this niche and to better understand the impact a wrist has in prosthetic functionality, we designed a low-cost, adaptable, 3D-printable prosthetic wrist that can be adapted to various prosthetic hands and sockets. The wrist utilizes inexpensive but powerful servo motors to provide simultaneous and proportional control of two degrees of freedom: pronation/supination and flexion/extension or radial/ulnar deviation. Participants used both our wrist and a commercially available wrist (DEKA \"LUKE\" Arm) to complete a modified version of the clothespin relocation task with and without the wrists enabled. Through use of the NASA Task Load Index we found that both wrists significantly reduced the subjective workload associated with clothespin relocation task (p < 0.05). However, we found no significant difference in task completion speed, presumably due to compensation strategies. This inexpensive and adaptable prosthetic wrist can be used by amputees to reduce task workload, or by researchers to further explore the importance of wrist function.

bioengineering↗