Search bioRxiv⌕ Search

Biology subjects

Dullin, C.

Publications and source records attributed to Dullin, C..

9 recordsLinked to original sources

Label-Free Multimodal Volumetric Imaging of Colon Cancer Tissue via Registration of Propagation-Based Phase-Contrast CT, Light-Sheet, and Three-Photon Microscopy

Multimodal 3D imaging has emerged as a powerful approach for investigating complex tissue architecture in pathological specimens. Techniques such as propagation-based phase-contrast computed tomography (PCT), light-sheet microscopy (LSM), and three-photon microscopy (3PM) provide complementary information on unlabeled tissue morphology based on distinct intrinsic contrast mechanisms. However, integrating these heterogeneous datasets into a unified spatial framework remains challenging due to differences in imaging geometry, spatial resolution, and modality-specific distortions. In this study, we present a registration pipeline for spatially aligning volumetric datasets acquired with PCT, LSM, and 3PM from formalin-fixed paraffin-embedded (FFPE) human colon cancer specimens. Biopsies from theses specimens were optically cleared and imaged sequentially using the three high-resolution modalities. To compensate for large positional differences between acquisitions, a three-stage cascade registration strategy was developed, consisting of coarse global alignment on down-sampled data, followed by rigid refinement at intermediate resolution. Mutual information was used as the similarity metric to ensure robust multimodal registration. The resulting framework enables the generation of spatially aligned multi-channel 3D datasets that combine structural information from X-ray phase-contrast imaging with complementary optical contrast signals. Beyond registration, we demonstrate that the fused six-dimensional feature space can be further exploited for unsupervised tissue characterization using a Gaussian Mixture Model (GMM), enabling data-driven identification of spatially coherent tissue regions without manual annotation. Qualitative evaluation confirms consistent alignment of major anatomical structures across modalities, while the unsupervised clustering reveals biologically meaningful patterns despite modality-specific noise and resolution differences. While further optimization and validation across larger datasets will enhance its computational efficiency and breadth of application, the approach already demonstrates strong potential for comprehensive tissue analysis and enables scalable, label-free 3D characterization of colon cancer tissue architecture.

pathology↗

Exploring Ventilator-Induced Lung Injury: A Comprehensive Ex-Vivo Study Using Phase-Contrast MicroCT and Atomic Force Microscopy

Mechanical ventilation (MV) can induce or exacerbate ventilator-induced lung injury (VILI), particularly in mechanically heterogeneous lungs with pre-existing injury. We investigated VILI in a rat model of bleomycin-induced lung injury and compared it with healthy controls using a combined in-vivo and ex-vivo imaging approach. Previously acquired in-vivo data from four-dimensional (4D) phase-contrast synchrotron micro-computed tomography (microCT) and forced oscillation measurements showed increased lung elastance and reduced local acinar strain in bleomycin-induced injured lungs at baseline and after injurious MV. To identify structural and mechanical correlates, we performed automated three-dimensional (3D) pore analysis and atomic force microscopy (AFM) on formalin-fixed, paraffin-embedded lung tissue, complemented by histology and spatial co-registration. Ex-vivo analysis revealed pronounced airspace enlargement after injurious MV of healthy lungs, whereas this effect was attenuated in fibrotic lungs. AFM demonstrated region-specific mechanical responses, and correlation analyses linked pore geometry and nanoscale stiffness to in-vivo lung mechanics. Spatial analysis further showed colocalization of VILI-associated airspace damage with injured regions. Overall, extracellular matrix remodelling modifies the lungs mechanical response to injurious MV. This multiscale correlative approach provides mechanistic insight into the interplay between lung injury and VILI and informs ventilation strategies in structurally altered lungs.

pathology↗

X-Ray contrast-adjustable 3D printing for multimodal fusion of microCT and histology

ObjectPhantoms and reference structures are essential tools for calibration and correlative imaging in pre-clinical and research applications of X-Ray-based imaging. They serve as reference standards, ensuring consistency and accuracy in imaging results. However, generating individual phantoms often involves a complex creation process, high production costs, and significant time investment. MethodConic reference structures were 3D printed using a mixture of UV-curable resin and X-Ray contrast agents. These structures were then embedded together with lung specimens of SARS-CoV-2-infected rhesus macaques in a methyl methacrylate-based solution. The polymerized blocks were scanned using propagation-based phase-contrast microCT, a method chosen for its superior ability to enhance contrast especially in low-absorbing biological samples. Utilizing the conic reference structures, subsequently performed histological sections were co-registered into the 3D context of the microCT data sets. ResultThe produced 3D-printing models were highly visible in terms of contrast and detail in both imaging methods, allowing for a precise co-registration of microCT and histological imaging. ConclusionThe novel methodology of using contrast agents and resin in 3D-printing enables the generation of customizable, contrast-specific phantoms and reference structures. These can be straightforwardly segmented from the embedding material, significantly simplifying and enhancing the workflow of multimodal imaging processes. In this study, 3D printed conic reference structures were effectively used to automate and streamline the precise multimodal fusion of microCT and histological imaging.

bioengineering↗

Interactive delineation and quantification of anatomical structure with virtual reality

A virtual environment, equipped with suitable data representations, interaction techniques, and method interfaces, can facilitate effective human-in-the-loop analytics of 3D data. Motivated by this observation, we propose Brainacle, a native editor for the interactive delineation and quantification of anatomical structures in virtual reality. We validate this in a case study, where we process the gross brain regions of 20 individual animals from six different species of African cichlid fish from the tribe Lamprologinii, endemic to Lake Tanganyika in Africa. The software presented in this article can be used to quickly visualise and obtain an overview of imaged animal tissues, visually communicate features of interest, interactively add delineations, and perform different measurements in the same 3D environment. Brainacle is made available free of charge at https://brainacle.org and on the research data repository DaRUS.

bioinformatics↗

Vapor-based Fixation of Pulmonary Tissue in its Physiological State: A Novel Approach to Histological Validation of Ultra High Resolution Phase Contrast CT in Human Sized Lungs

Lung diseases continue to present a major burden on public health. Therefore, improving the process of diagnosis by the development of novel imaging techniques is of great importance. In this perspective, phase sensitive CT imaging techniques such as propagation based imaging (PBI) might play an important role as they allow increasing the spatial resolution at very low x-ray dose levels that are comparable to clinical CT. However, the development of such methods is not only hindered by technological problems but also by the lack of precise validation strategies. We adapted formaldehyde (FA) vapor fixation to demonstrate that fresh porcine lungs that have been investigated by PBI can be fixed in their physiological shape and studied by multi-scale microCT imaging as well as classical histology. In addition, we show that FA vapor fixed pig lungs can be scanned by PBI without visible deterioration of image quality compared to fresh tissue. This opens the possibility of fixing and storing, for instance, human lung tissue before performing a PBI experiment, which in turn allows to study pathological changes in human lungs without questioning the translate-ability of findings in pig lung. The setup can be used by any interested researchers.

pathology↗

Integrative Imaging of Lung Micro Structure: Amplifying Classical Histology by Paraffin Block μCT and same-slide Scanning Electron Microscopy

Classical histopathology of formalin fixed and paraffin embedded (FFPE) tissue using light microscopy (LM) remains the undisputed gold standard in biomedical microstructural lung tissue analysis. To extend this method, we developed an integrative imaging and processing pipeline which adds 3D context and screening capabilities by micro-CT (CT) imaging of the entire paraffin block and adds ultrastructural information by correlative same-slide scanning electron microscopy (SEM). The different modalities are integrated by elastic registration to provide hybrid image datasets. Without compromising standard light microscopic readout, we overcome the limitations of conventional histology by combining and integrating several imaging modalities. The biochemical information contained in histological and immunohistological tissue staining is embedded into the 3D tissue configuration and is amplified by adding ultrastructural visualization of features of interest. By combining CT and conventional histological processing, specimens can be screened, and specifically preselected areas of interest can be targeted in the subsequent sectioning process. While most of the CT data shown in the manuscript was acquired at a Synchrotron, we further demonstrate that our workflow can also by applied using X-ray microscopy.

pathology↗

Autonomous bioluminescence emission from transgenic mice

The bacterial bioluminescence system can be applied to produce autonomous bioluminescence in mammalian cells. Until now, the system has only been stably inserted into cells cultured in vitro. Here we report the generation of an autobioluminescent transgenic mouse line constitutively expressing the genes of the bacterial bioluminescence system, enabling substrate-free in vivo luminescence imaging of a living mammal.

bioengineering↗

Axon demyelination and degeneration in a zebrafishspastizin model of hereditary spastic paraplegia

Hereditary spastic paraplegias (HSPs) are a diverse set of neurological disorders characterized by progressive spasticity and weakness in the lower limbs caused by damage to the axons of the corticospinal tract. More than 88 genetic mutations have been associated with HSP, yet the mechanisms underlying these disorders are little understood. We studied the pathogenesis of one form of HSP known as spastic paraplegia 15 (SPG15). This disorder is caused by mutations in the ZFYVE26 gene, which codes for a protein called SPASTIZIN. We show that, in zebrafish, the significant reduction of Spastizin caused degeneration of Mauthner (M)-cells. M-cell degeneration is associated with axon demyelination in the spinal cord and impaired locomotion in the spastizin mutants. Our findings reveal that the mutation not only compromises axonal integrity but also affects the structural molecules of the myelin sheath, laying the foundation for degeneration and advancing our understanding of the intricate mechanisms underlying HSPs.

neuroscience↗

Whole-body plethysmography revisited

Whole-body plethysmography (WBP) is an established method to determine physiological parameters and pathophysiological alteration of breathing in animals and animal models of a variety of diseases, reaching from pulmonary diseases to complex neurological syndromes. Although frequently used, there is ongoing debate about what exactly is measured by whole-body-plethysmography and how reliable the data derived from this method are? Here, we designed a simple device that can serve as an artificial lung model that enables a thorough evaluation of different predictions about and around whole-body plethysmography. Using our lung model, we confirmed that during WBP two components contribute to the pressure changes detected in the chamber: 1) the increase of the pressure due to heating and moistening of the air, termed as conditioning, during inspiration; 2) changes of chamber pressure that depend on airway resistance. Both components overlap and contribute to the temporal pressure-profile measured in the chamber or across the wall of the chamber. Our data showed that a precise measurement of the breathing volume appears to be hindered by at least two factors: 1) the unknown relative contribution of each of these components; 2) not only the air in the inspired volume is conditioned during inspiration, but also air within the residual volume and death space that is recruited during inspiration. Moreover, our data suggest that the expiratory negative pressure peak that is used to determine the so called "enhanced pause" (Penh) parameter is not a measure for airway resistance as such but rather a consequence of the animals response to the airway resistance, using active expiration to overcome the resistance by a higher thoracic pressure.

physiology↗