Search bioRxiv⌕ Search

Biology subjects

Dryg, I.

Publications and source records attributed to Dryg, I..

4 recordsLinked to original sources

Reducing the Foreign Body Reaction to Neuronal Implants in the Central Nervous System with Porous Precision-templated, Mechanically Compliant Hydrogel Scaffolds

Central nervous system diseases and injuries might be treated by implanted devices, tissue regenerative scaffolds, or drug delivery platforms. However, inflammatory CNS responses limit these interventions and may worsen outcomes following damage to the CNS. Via the foreign body reaction, macrophages and glial cells trigger a "glial scar" around implants, reducing device performance, scaffold regenerative ability, or drug delivery potential. Previous studies have shown that stiffness of CNS implants significantly affects glial encapsulation, but few studies have investigated materials that truly match brain tissue stiffness. Porous precision-templated scaffolds with uniform, interconnected, 40 {micro}m spherical pores have shown favorable healing outcomes and a reduced FBR in numerous soft and hard tissue applications. To quantify the effects of both hydrogel compliance (stiffness) and pore size on glial encapsulation, we implanted poly(2-hydroxyethyl methacrylate-co-glycerol methacrylate) (pHEMA/GMA) scaffolds of varying stiffness and pore size for 4 weeks in rat brain. We observed reduced astrocyte encapsulation around PTS compared to solid hydrogel rods, reduced pro-inflammatory macrophage polarization for softer hydrogels versus stiffer hydrogels, and the presence of new blood vessels, neuronal markers and neurogenesis within the pores. Utilizing soft, precision-porous hydrogels could provide a strategy for mitigating glial scarring and improving regeneration in implant-based CNS treatments.

bioengineering↗

Pan-cancer spatial characterization of key immune biomarkers in the tumor microenvironment

Deciphering the composition and spatial organization of the tumor immune microenvironment (TiME) is key to uncovering the mechanisms driving cancer progression and treatment response. Spatial biology techniques like multiplex immunofluorescence (mIF) offer detailed insights into the TiME but are often limited to retrospective research studies of individual cancer types. Conversely, bulk omics techniques have been studied in pan-cancer settings but fail to capture single-cell spatial information. Here, we provide a pan-cancer spatial characterization of key biomarkers (CD8, FOXP3, PD-1, PD-L1) of the TiME using data from a mIF assay performed prospectively in a clinical setting on 2,019 tumors across 14 major cancer types. By integrating interpretable compositional and spatial metrics, we identified patterns of TiME variation that are conserved across cancer types and stages. We assess associations between these TiME spatial factors and tumor, genomic, and clinical features, where the results both extend prior findings and uncover new links. Altogether, our findings offer pan-cancer insights of the TiME to further the fields of spatial biology and cancer immunology.

cancer biology↗

Recurrence of cancer cell states across diverse tumors and their interactions with the microenvironment

While genetic tumor heterogeneity has long been recognized, recent work has revealed significant variation among cancer cells at the epigenetic and transcriptional levels. Profiling tumors at the single-cell level in individual cancer types has shown that transcriptional heterogeneity is organized into cancer cell states, implying that diverse cell states may represent stable and functional units with complementary roles in tumor maintenance and progression. However, it remains unclear to what extent these states span tumor types, constituting general features of cancer. Furthermore, the role of cancer cell states in tumor progression and their specific interactions with cells of the tumor microenvironment remain to be elucidated. Here, we perform a pan-cancer single-cell RNA-Seq analysis across 15 cancer types and identify a catalog of 16 gene modules whose expression defines recurrent cancer cell states, including stress, interferon response, epithelial-mesenchymal transition, metal response, basal and ciliated. Using mouse models, we find that induction of the interferon response module varies by tumor location and is diminished upon elimination of lymphocytes. Moreover, spatial transcriptomic analysis further links the interferon response in cancer cells to T cells and macrophages in the tumor microenvironment. Our work provides a framework for studying how cancer cell states interact with the tumor microenvironment to form organized systems capable of immune evasion, drug resistance, and metastasis.

cancer biology↗

Long-term in vivo Monitoring of Gliotic Sheathing of Ultrathin Entropic Coated Brain Microprobes with Fiber-based Optical Coherence Tomography

Microfabricated neuroprosthetic devices have made possible important observations on neuron activity; however, long-term high-fidelity recording performance of these devices has yet to be realized. Tissue-device interactions appear to be a primary source of lost recording performance. The current state of the art for visualizing the tissue response surrounding brain implants in animals is Immunohistochemistry + Confocal Microscopy, which is mainly performed after sacrificing the animal. Monitoring the tissue response as it develops could reveal important features of the response which may inform improvements in electrode design. Optical Coherence Tomography (OCT), an imaging technique commonly used in ophthalmology, has already been adapted for imaging of brain tissue. Here, we use OCT to achieve real-time, in vivo monitoring of the tissue response surrounding chronically implanted neural devices. The employed tissue-response-provoking implants are coated with a plasma-deposited nanofilms, which have been demonstrated as a biocompatible and anti-inflammatory interface for indwelling devices. We evaluate the method by comparing the OCT results to traditional histology qualitatively and quantitatively. The differences in OCT signal across the implantation period between the plasma group and the control reveal that the Parylene-type coating of otherwise rigid brain probes (glass and silicon) does not improve the glial encapsulation in the brain parenchyma.

bioengineering↗