Search bioRxiv⌕ Search

Biology subjects

Doherty, E.

Publications and source records attributed to Doherty, E..

3 recordsLinked to original sources

Towards Ecological Measurement of Complex Cognitive Processes: Functional-Near Infrared Spectroscopy of Brain Activity During Reading

Functional magnetic resonance imaging (fMRI) has provided unparalleled insights into the fundamental neural mechanisms governing human cognition, including complex processes such as reading. Here, we leverage the wealth of prior fMRI work to capture reading outside the MRI scanner using functional near infra-red spectroscopy (fNIRS). In a large sample of participants (n = 82) we observe significant prefrontal and temporal fNIRS activations during reading, which are largely reliable across participants, therefore providing a robust validation of prior fMRI work on reading-related language processing. These results lay the groundwork towards developing adaptive systems capable of assisting these higher-level processes, for example to support readers and language learners. This work also contributes to bridging the gap between laboratory findings and real-world applications in the realm of cognitive neuroscience.

neuroscience↗

Mucus production, host-microbiome interactions, hormone sensitivity, and innate immune responses modeled in human endo- and ecto-cervix chips

Modulation of mucus production by the human endo- and ecto-cervical epithelium by steroid hormones and associated interactions with commensal microbiome play a central role in the physiology and pathophysiology of the female reproductive tract. However, most of our knowledge about these interactions is based on results from animal studies or in vitro models that fail to faithfully mimic the mucosal environment of the human cervix. Here we describe microfluidic organ-on-a-chip (Organ Chip) models of the human cervical mucosa that recreate the cervical epithelial-stromal interface with a functional epithelial barrier and produce abundant mucus that has compositional, biophysical, and hormone-responsive properties similar to the living cervix. Application of continuous fluid flow to chips lined with primary human cervical epithelial cells from a commercial source that contained a mixture of primary human ecto- and endo-cervical epithelial cells promoted preferential expression of the ecto-cervical phenotype, whereas use of periodic flow including periods of stasis induced endo-cervical specialization. When the periodic flow Cervix Chips were co-cultured with living Lactobacillus crispatus and Gardnerella vaginalis bacterial communities to respectively mimic the effects of human host interactions with optimal (healthy) or non-optimal (dysbiotic) microbiome associated with an ascending infection in the female reproductive tract, significant differences in tissue innate immune responses, barrier function, cell viability and protein profile, and mucus composition were detected reminiscent of those observed in vivo. Thus, these Organ Chip models of human cervix provide a physiologically relevant experimental in vitro model to study cervical mucus physiology and its role in human host-microbiome interactions as well as a potential preclinical testbed for development of therapeutic interventions to enhance womens health.

bioengineering↗

Vaginal microbiome-host interactions modeled in a human vagina-on-a-chip

BackgroundA dominance of non-iners Lactobacillus species in the vaginal microbiome is optimal and strongly associated with gynecological and obstetric health, while the presence of diverse obligate or facultative anaerobic bacteria and a paucity in Lactobacillus species, similar to communities found in bacterial vaginosis (BV), is considered non-optimal and associated with adverse health outcomes. Various therapeutic strategies are being explored to modulate the composition of the vaginal microbiome; however, there is no human model that faithfully reproduces the vaginal epithelial microenvironment for preclinical validation of potential therapeutics or testing hypotheses about vaginal epithelium-microbiome interactions. ResultsHere, we describe an organ-on-a-chip (Organ Chip) microfluidic culture model of the human vaginal mucosa (Vagina Chip) that is lined by hormone-sensitive, primary vaginal epithelium interfaced with underlying stromal fibroblasts, which sustains a low physiological oxygen concentration in the epithelial lumen. We show that the Vagina Chip can be used to assess colonization by optimal L. crispatus consortia as well as non-optimal Gardnerella vaginalis-containing consortia, and to measure associated host innate immune responses. Co-culture of the L. crispatus consortia was accompanied by maintenance of epithelial cell viability, accumulation of D- and L-lactic acid, maintenance of a physiologically relevant low pH, and down regulation of proinflammatory cytokines. In contrast, co-culture of G. vaginalis-containing consortia in the Vagina Chip resulted in epithelial cell injury, a rise in pH, and upregulation of proinflammatory cytokines. ConclusionThis study demonstrates the potential of applying human Organ Chip technology to create a preclinical model of the human vaginal mucosa that can be used to better understand interactions between the vaginal microbiome and host tissues, as well as to evaluate the safety and efficacy of live biotherapeutics products.

microbiology↗