Search bioRxiv⌕ Search

Biology subjects

DelaBarre, L.

Publications and source records attributed to DelaBarre, L..

5 recordsLinked to original sources

An 80-channel receive array for 10.5T neuroimaging: Key considerations for SNR optimization

PurposeHigh-density RF receive arrays are required to realize the inherently available SNR and parallel imaging advantages at ultrahigh field strengths, which are essential for high-resolution functional and anatomical brain MRI. This study aims to systematically assess the impacts of often-overlooked parasitic losses associated with various RF coil components, as these losses can degrade the realized SNR and cause significant deviation from the ultimate intrinsic SNR (uiSNR; the theoretical upper bound of available SNR). In addition, we seek to detail engineering solutions to each of these loss mechanisms in pursuit of achieving a higher fraction of the uiSNR limit. MethodsA 16-channel loop-folded dipole transceiver array was developed for 10.5T human head applications and paired with a fully-updated 64-channel receive-only loop array. The optimization of the receive array considered several factors, including (but not limited to) coil dimensions to accommodate a larger population, the size and number of loops to enhance SNR and parallel imaging performance, and circuit design strategies to minimize parasitic losses. The SNR and parallel imaging performance of the receive array were quantitatively assessed by comparison with the uiSNR, as well as existing high-channel-count receive arrays at 7T and 10.5T. Finally, the complete 16-channel transmit, 80-channel receive coil array was safety validated for human use and employed for high-resolution functional and anatomical MRI at 10.5T. ResultsInitial results show that the 80-channel array, featuring larger loops in an overlapped layout with optimized circuitry, significantly improves the SNR and approaches the uiSNR limit in a large fraction of the head, while maintaining or enhancing the parallel imaging performance compared to previously used non-overlap layout. ConclusionThis study suggests that, although the traditionally used high-channel-count loop receive array technology can approach the uiSNR limit in the >10T regime, meticulous design optimization--including systematic assessment and minimization of parasitic losses--has become increasingly critical for achieving this goal in this new field-strength territory.

neuroscience↗

A Numerical Alternative to MR Thermometry for Safety Validation of Multi-Channel RF Transmit Coils

PurposeThis study proposes an alternative approach to MR thermometry (MRT) for the safety validation of multi-channel RF transmit coils and demonstrates its use to enable human studies at 10.5T. MethodsTo ensure patient safety, specific absorption rate (SAR) limits established under international guidelines must not be exceeded. Predicting SAR on state-of-the-art parallel transmit systems relies on electromagnetic simulations, which require extensive experimental validation. Despite a well-established validation workflow, SAR prediction errors are unavoidable and must be quantified as a safety margin. While MRT tests are commonly used for this purpose, their technical challenges necessitate an alternative. The proposed technique propagates the error between experimentally and numerically acquired B+distributions to the uncertainty in simulated peak local SAR using Monte-Carlo simulations without the need for MRT. This method was validated using a 16-channel transceiver coil for imaging the human torso (henceforth referred to as a "body" coil) at 10.5T with two excitation scenarios, as well as an 8-channel 10.5T head coil with four excitation scenarios. ResultsThe proposed numerical technique proved more conservative than existing MRT-based SAR error quantification methods across all tested scenarios. Its application to validate three state-of-the-art head coils (16Tx/32Rx, 16Tx/80Rx, and 16Tx/128Rx) led to regulatory approval for human head imaging and high-quality functional as well as diffusion MRI results at 10.5T. ConclusionA numerical alternative to MRT requires only the experimental acquisition of B+ maps for comparison with simulations, enabling the quantification of uncertainty in SAR prediction. This technique was applied to three 16-channel transmit arrays, each used in conjunction with high-channel-count receive arrays for in vivo imaging.

neuroscience↗

A 128-channel receive array with enhanced SNR performance for 10.5 tesla brain imaging

PurposeTo develop and characterize the performance of a 128-channel head array for brain imaging at 10.5 tesla and evaluate the potential of brain imaging at this unique, >10 tesla magnetic field. MethodsThe coil is composed of a 16-channel self-decoupled loop transmit/receive array with a 112-loop receive-only (Rx) insert. Interactions between the outer transmitter and the inner 112Rx insert were mitigated using coaxial cable traps placed every 1/16 of a wavelength on each feed cable, locating most preamplifier boards outside the transmitter field and miniaturizing those placed directly on individual coils. ResultsThe 128-channel array described herein achieved 77% of ultimate intrinsic SNR in the center of the brain. Transmit field maps obtained experimentally on a phantom with and without the receive array were similar and matched EM simulations, leading to FDA approval for human imaging. Anatomical and functional data, including with power demanding sequences, were acquired successfully on human volunteers. ConclusionsCounterintuitive to expectations based on magnetic fields [≤]7T, the higher channel counts provided SNR gains centrally, capturing [~]80% uiSNR. Fraction of uiSNR achieved centrally in 64Rx, 80Rx, and 128Rx arrays suggested that a plateau was being reached at 80%. At this plateau, linear to approximately quadratic B0 dependent SNR gains for the periphery and the center, respectively, were observed for 10.5T relative 7T.

neuroscience↗

RF coil design strategies for improving SNR at theultrahigh magnetic field of 10.5 Tesla

PurposeTo develop multichannel transmit and receive arrays towards capturing the ultimate-intrinsic-SNR (uiSNR) at 10.5 Tesla (T) and to demonstrate the feasibility and potential of whole-brain, high-resolution human brain imaging at this high field strength. MethodsA dual row 16-channel self-decoupled transmit (Tx) array was converted to a 16Tx/Rx transceiver using custom transmit/receive switches. A 64-channel receive-only (64Rx) array was built to fit into the 16Tx/Rx array. Electromagnetic modeling and experiments were employed to define safe operation limits of the resulting 16Tx/80Rx array and obtain FDA approval for human use. ResultsThe 64Rx array alone captured approximately 50% of the central uiSNR at 10.5T while the identical 7T 64Rx array captured [~]76% of uiSNR at this lower field strength. The 16Tx/80Rx configuration brought the fraction of uiSNR captured at 10.5T to levels comparable to the performance of the 64Rx array at 7T. SNR data obtained at the two field strengths with these arrays displayed [Formula] dependent increases over a large central region. Whole-brain high resolution T2* and T1 weighted anatomical and gradient-recalled echo EPI BOLD fMRI images were obtained at 10.5T for the first time with such an advanced array, illustrating the promise of >10T fields in studying the human brain. ConclusionWe demonstrated the ability to approach the uiSNR at 10.5T over the human brain with a novel, high channel count array, achieving large SNR gains over 7T, currently the most commonly employed ultrahigh field platform, and demonstrate high resolution and high contrast anatomical and functional imaging at 10.5T.

neuroscience↗

An 8 Dipole Transceive and 24 Loop Receive Array for Non-Human Primate Head Imaging at 10.5T

A 32-channel RF coil was developed for brain imaging of anesthetized non-human primates (Rhesus Macaque) at 10.5 tesla. The coil is composed of an 8-channel dipole transmit/receive array, close-fitting 16-channel loop receive array headcap, and 8-channel loop receive array lower insert. The transceiver dipole array is composed of eight end-loaded dipole elements self-resonant at the 10.5 tesla proton Larmor frequency. These dipole elements were arranged on a plastic cylindrical former which was split in two to allow for convenient animal positioning. Nested into the bottom of the dipole array former is located an 8-channel loop receive array which contains 5x10 cm2 square loops arranged in two rows of four loops. Arranged in a close-fitting plastic headcap is located a high-density 16-channel loop receive array. This array is composed of 14 round loops 37 mm in diameter and two partially detachable, irregularly shaped loops that encircle the ears. Imaging experiments were performed on anesthetized non-human primates on a 10.5 tesla MRI system equipped with body gradients with a 60 cm open bore. The coil enabled submillimeter (0.58 mm isotropic) high resolution anatomical and functional imaging as well as tractography of fasciculated axonal bundles. The combination of a close-fitting loop receive array and dipole transceiver array allowed for a higher channel count receiver and consequent higher SNR and parallel imaging gains. Parallel imaging performance supports high resolution fMRI and dMRI with a factor of three reduction in sampling. The transceive array elements during reception contributed approximately one quarter of SNR in the lower half of the brain which was farthest from the close-fitting headcap receive array.

bioengineering↗