Search bioRxivSearch

Biology subjects

Debnath, R.

Publications and source records attributed to Debnath, R..

2 recordsLinked to original sources

The Maryland Analysis of Developmental EEG (MADE) Pipeline

Compared to adult EEG, EEG signals recorded from pediatric populations have shorter recording periods and contain more artifact contamination. Therefore, pediatric EEG data necessitate specific preprocessing approaches in order to remove environmental noise and physiological artifacts without losing large amounts of data. However, there is presently a scarcity of standard automated preprocessing pipelines suitable for pediatric EEG. In an effort to achieve greater standardization of EEG preprocessing, and in particular for the analysis of pediatric data, we developed the Maryland Analysis of Developmental EEG (MADE) pipeline as an automated preprocessing pipeline compatible with EEG data recorded with different hardware systems, different populations, levels of artifact contamination, and length of recordings. MADE uses EEGLAB and functions from some EEGLAB plugins, and includes additional customizable features particularly useful for EEG data collected from pediatric populations. MADE processes event-related and resting state EEG from raw data files through a series of preprocessing steps and outputs processed clean data ready to be analyzed in time, frequency, or time-frequency domain. MADE provides a report file at the end of the preprocessing that describes a variety of features of the processed data to facilitate the assessment of the quality of processed data. In this paper we discuss some practical issues, which are specifically relevant to pediatric EEG preprocessing. We also provide custom-written scripts to address these practical issues. MADE is freely available under the terms of the GNU General Public License at https://github.com/ChildDevLab/MADE-EEG-preprocessing-pipeline.

neuroscience

Adjusting ADJUST: Optimizing the ADJUST Algorithm for Pediatric Data Using Geodesic Nets

A major challenge for electroencephalograph (EEG) studies on pediatric populations is that large amounts of data are lost due to artifacts (e.g., movement and blinks). Independent component analysis (ICA) can separate artifactual and neural activity, allowing researchers to remove such artifactual activity and retain a greater percentage of EEG data for analyses. However, manual identification of artifactual components is time consuming and requires subjective judgment. Automated algorithms, like ADJUST and ICLabel, have been validated on adults using the international 10-20 system, but to our knowledge no such algorithms have been optimized for the geodesic sensor net, which is often used with infants and children. Therefore, in an attempt to automate artifact selection for pediatric data collected with geodesic nets, we modified ADJUSTs algorithm. Our \"adjusted-ADJUST\" algorithm was compared to the \"original-ADJUST\" algorithm and ICLabel in adults, children, and infants on three different performance measures: respective classification agreement with expert coders, the number of trials retained following artifact removal, and the reliability of the EEG signal after pre-processing with each algorithm. Overall, the adjusted-ADJUST algorithm performed better than the original-ADJUST algorithm and no ICA correction with adult and pediatric data. Moreover, it performed better than ICLabel for pediatric data. These results indicate that optimizing existing algorithms for data collected with a geodesic net improves artifact classification and retains more trials, potentially facilitating EEG studies with pediatric populations.

neuroscience