Search bioRxiv⌕ Search

Biology subjects

DeBono, N. J.

Publications and source records attributed to DeBono, N. J..

3 recordsLinked to original sources

Development of a Matrix-Matched Calibration Curve for Multi-Site Quantification of Neu5Gc-Bearing N-Glycans

N-glycolylneuraminic acid (Neu5Gc) has been repeatedly associated with human cancer, but reliable detection has remained elusive, generating controversy regarding its presence in human samples. To address this, matrix-matched calibration curves, which have been pioneered in proteomics and metabolomics for assessing changes in complex mixtures, were measured of released N-glycans at four orders of magnitude dynamic range in defined mixtures, systematically benchmarking Neu5Gc-containing N-glycan detection across multiple LC-MS platforms and sites. Orthogonally, the gold-standard analytical method, consisting of fluorescence detection of labelled monosaccharides separated by LC, was applied to the same samples, yielding absolute concentrations of Neu5Gc. LC-MS demonstrated an extended detection range of three or more orders of magnitude while retaining intact N-glycan measurement, improving assay specificity and enabling detection of the variety of Neu5Gc-bearing N-glycans. By combining orthogonal dimensions of evidence, including chromatographic separation, isotopic distribution matching, and composition-confirming MS/MS, LC-MS confidently resolved Neu5Gc signals from noise, even at low abundance. In comparison, DMB-LC-FLR was limited to two orders of magnitude dynamic range, insufficient for detection of Neu5Gc in commercially available pooled human sera. These findings strongly support that DMB-LC-FLR assay specificity and sensitivity are insufficient for Neu5Gc detection in human samples due to noise overwhelming the Neu5Gc signal. By establishing a reusable benchmarking framework for future glycomic studies, we aim to use LC-MS to improve the measurement of Neu5Gc in clinical samples.

biochemistry↗

Immobilised enzyme reactors for post-production glycan modification of purified glycoproteins

Controlling protein glycosylation as a critical quality attribute of biopharmaceuticals remains challenging when glycosylation is coupled to cellular production systems. Here, we present a proof-of-concept glycosyltransferase immobilised enzyme reactor (IMER) housed within a 3D-printed column that enables directed post-production glycan modification of purified glycoproteins. Using {beta}-1,4-galactosyltransferase ({beta}4GalT1-IMER) and -2,6-sialyltransferase (ST6Gal1-IMER) immobilised on Ni-NTA resin, the IMER achieved near-complete galactosylation and substantial sialylation of partially deglycosylated bovine fetuin N-glycans with their respective substrates with a maximum substrate-enzyme contact time of four minutes. Isomeric-level analysis revealed arm-specific addition preferences for both enzymes, consistent with known specificities. The modular IMER design permits sequential connection of individual enzyme chambers, potentially offering a scalable, plug-and-play platform for constructing defined glycan structures on recombinant glycoprotein therapeutics.

molecular biology↗

The molecular basis of immunosuppression by soluble CD52 is defined by interactions of N-linked and O-linked glycans with HMGB1 Box B

AbstractHuman soluble CD52 is a short glycopeptide comprising 12 amino acids (GQNDTSQTSSPS) which functions as an immune regulator by sequestering the pro-inflammatory high mobility group box protein 1 (HMGB1) and supressing immune responses. Recombinant CD52 has been shown to act as a broad anti-inflammatory agent, dampening both adaptive and innate immune responses. This short glycopeptide is heavily glycosylated, with a complex sialylated N-linked glycan at N3 and reported O- linked glycosylation possible on several serine and threonine residues. Previously we demonstrated that specific glycosylation features of CD52 are essential for its immunosuppressive function, with terminal -2,3-linked sialic acids required for binding to the inhibitory SIGLEC-10 receptor leading to T-cell suppression. Using high resolution mass spectrometry, we have further characterised the N- and O-linked glycosylation of Expi293 recombinantly produced CD52 at a glycopeptide and released glycan level, accurately determining glycan heterogeneity of both N- and O-linked glycosylation, and localising the site of O-glycosylation to T8 with high confidence and direct spectral evidence. This detailed knowledge of CD52 glycosylation informed the construction of a model system, which we analysed by molecular dynamics simulations to understand the mechanism of recognition and define interactions between bioactive CD52, HMGB1 and the SIGLEC-10 receptor. Our results confirm the essential role of glycosylation, more specifically hyper-sialylation, in the function of CD52, and identify at the atomistic level specific interactions between CD52 glycans and the Box B domain of HMGB1 that determine recognition, and the stability of the CD52/HMGB1 complex. These insights will inform the development of synthetic CD52 as an immunotherapeutic agent.

molecular biology↗