Search bioRxivSearch

Biology subjects

Day, S. W.

Publications and source records attributed to Day, S. W..

3 recordsLinked to original sources

The Effect of Blood Viscosity on Shear-Induced Hemolysis using a Magnetically Levitated Shearing Device

IntroductionBlood contacting medical devices, including rotary blood pumps, can cause shear-induced blood damage that may lead to adverse effects in patients. Due in part to an inadequate understanding of how cell-scale fluid mechanics impact red blood cell membrane deformation and damage, there is currently not a uniformly accepted engineering model for predicting blood damage caused by complex flow fields within ventricular assist devices (VADs). MethodsWe empirically investigated hemolysis in an axial Couette flow device typical of a rotary VAD to expand our current understanding of shear-induced blood damage in two ways. First, we used a magnetically levitated device to accurately control the shear rate and exposure time experienced by blood and to minimize the effects of other uncharacterized stresses. Second, we explored the effects of both hematocrit and plasma viscosity on shear-induced hemolysis to characterize blood damage based on the viscosity-independent shear rate, rather than on shear stress. ResultsOver a shear rate range of 20,000-80,000 1/s, the Index of Hemolysis was found to be largely independent of hematocrit, bulk viscosity, or the suspension media viscosity. ConclusionIt is recommended that future investigations of shear-induced blood damage report findings with respect to the viscosity-neutral term of shear rate, in addition to the bulk whole blood viscosity measured at an appropriate shear rate relevant to the flow conditions of the device.

bioengineering

A power amplification dyad in seahorses

Ubiquitous constraints derived from the muscles structure limit the power capacity of fast contracting muscles. Correspondingly, organisms evolved elastic elements that store energy which, when released, can be used to rapidly accelerate appendages. Such latch-mediated spring actuation (LaMSA) systems comprise of a single elastic element and are used to actuate a single mass. Here we reveal a dual LaMSA system in seahorses, in which two elastic elements actuate two masses: the head as they rapidly swing it towards the prey, and the water mass sucked into the mouth to prevent the prey from escaping. This power-amplified system enhances the speeds of both head rotation and suction flows by x10 compared to similarly-sized fish. Furthermore, the dual system provides temporal coordination between head rotation and suction flows, a novel function for LaMSA. These findings extend the known function, capacity and design of LaMSA systems.

biophysics

Numerical Model to Predict Hemolysis and Transport in a Membrane-Based Microfluidic Device

Microfluidic devices promise to overcome the limitations of conventional hemodialysis and oxygenation technologies by incorporating novel membranes with ultrahigh permeability into portable devices with low blood volume. However, the characteristically small dimensions of these devices contribute to both non-physiologic shear that could damage blood components and laminar flow that inhibits transport. While many studies have applied empirical and computational models of hemolysis to medical devices, such as valves and blood pumps, little is known about blood damage in the microfluidic flow regime. In this study, four design variants of a microfluidic membrane-based oxygenator and two controls (positive and negative) are introduced and modeled using a Computational Fluid Dynamics (CFD) model to predict hemolysis. The simulations were performed in ANSYS Fluent for nine shear stress-based Power Law hemolysis model variants. Empirical testing of the devices in a recirculating loop revealed levels of hemolysis significantly lower (3 ppm hemolysis for pump, tube, and device combined) than the hemolysis ranges (>10 ppm) observed in conventional oxygenators. We found that most of the nine tested hemolysis models overpredict (5x to 10x) hemolysis compared to empirical experiments. However, two models demonstrated higher predictive accuracy for hemolysis values in devices characterized by low shear conditions, while another set of three models exhibited better performance for devices operating under higher shear conditions. Our study highlights the limitations of combining hemolysis models with computational fluid dynamics models for a priori in silico device-induced hemolysis. Nevertheless, with a judicious selection of hemolysis models based on the shear ranges of the test device, we propose that computational modeling can complement empirical testing in the development of novel micro-dialyzers or oxygenators, allowing for a more efficient iterative design process. Furthermore, the low device-induced hemolysis (< 2 ppm) measured in our study at physiologically relevant flow rates is promising for the future development of microfluidic dialyzers and oxygenators.

bioengineering