Search bioRxiv⌕ Search

Biology subjects

Collins, J. T.

Publications and source records attributed to Collins, J. T..

3 recordsLinked to original sources

Beyond Navigation - Tissue-contacting Fluorescent Lifetime Imaging reveals a pathology-linked lung cancer phenotype at the point of biopsy

Background: Accurate sampling of suspected peripheral lung cancers depends on access to the lesion and confirmation that the biopsy tool is in contact with target tissue. Current bronchoscopic navigation and imaging techniques can guide instruments to a target but do not provide real-time biological confirmation at the point of sampling. Fluorescence lifetime imaging microscopy (FLIM) provides molecular contrast by measuring fluorescence decay - how long photons continue to be emitted from fluorescent molecules. In the Precision Lung clinical study (ISRCTN15093468), the Prothea Imaging System (Generation 1) identified a candidate tumour-associated phenotype of spatially overlapped low fluorescence lifetime and low intensity (LLLI) from in-vivo imaging. We used this observation as the basis for a reverse-translational study to determine whether the LLLI phenotype is linked to cancer pathology; reproducible with the Imaging System (Generation 2); and distinguishable from normal lung tissue. Methods: Previously reported Precision Lung findings were used as the clinical starting observation and were not re-analysed. Validation was then performed using: (i) pathology linked benchtop FLIM of early-stage non-small-cell lung tissue microarrays encompassing malignant cell clusters of approximately 300 um2, matched to the EoT imaging scale; (ii) five sequential fresh lung-cancer resections imaged at tumour and comparator regions, including visibly blood-rich contact sites, using the (Generation 2) Imaging System; and (iii) systematic mapping of two ventilated non-cancer donor lungs, one from a smoker and one from a non-smoker, across all available lobes. The LLLI phenotype was defined as spatial co-localisation of low intensity and short lifetime. Results: Using a real time fibre based FLIM system, capable of deployment through a working channel of a bronchoscope, the LLLI tumour phenotype was optically identified in freshly resected tumour tissue. The same phenotype was identified in fixed tissue samples with known pathology, and with images taken in the Precision Lung clinical study. Whole human lung controls did not show evidence of the tumour phenotype. Conclusions: This evidence forms a reverse-translational chain that supports the concept of the Prothea Imaging System - as a platform that confirms that the tool is in contact with a region of cancer in the lesion, while preserving continuous access for biopsy or intervention.

cancer biology↗

An Open-Source Modular Framework for Automated Pipetting and Imaging Applications

The number of samples in biological experiments are continuously increasing, but complex protocols and human experimentation in many cases lead to suboptimal data quality and hence difficulties in reproducing scientific findings. Laboratory automation can alleviate many of these problems by precisely reproducing machine-readable protocols. These instruments generally require high up-front investments and due to lack of open APIs they are notoriously difficult for scientists to customize and control outside of the vendor-supplied software. Here, we demonstrate automated, high-throughput experiments for interdisciplinary research in life science that can be replicated on a modest budget, using open tools to ensure reproducibility by combining the tools Openflexure, Opentrons, ImJoy and UC2. Our automated sample preparation and imaging pipeline can easily be replicated and established in many laboratories as well as in educational contexts through easy-to-understand algorithms and easy-to-build microscopes. Additionally, the creation of feedback loops, with later pipetting or imaging steps depending on analysis of previously acquired images, enables the realization of smart microscopy experiments, featuring completely autonomously performed experiments. All documents and source-files are publicly available (https://beniroquai.github.io/Hi2) to prove the concept of smart lab automation using inexpensive, open tools. We believe this democratizes access to the power and repeatability of automated experiments.

cell biology↗

Robotic microscopy for everyone: the OpenFlexure Microscope

Optical microscopes are an essential tool for both the detection of disease in clinics, and for scientific analysis. However, in much of the world access to high-performance microscopy is limited by both the upfront cost and maintenance cost of the equipment. Here we present an open-source, 3D-printed, and fully-automated laboratory microscope, with motorised sample positioning and focus control. The microscope is highly customisable, with a number of options readily available including trans- and epi-illumination, polarisation contrast imaging, and epi-florescence imaging. The OpenFlexure Microscope has been designed to enable low-volume manufacturing and maintenance by local personnel, vastly increasing accessibility. We have produced over 100 microscopes in Tanzania and Kenya for educational, scientific, and clinical applications, demonstrating that local manufacturing can be a viable alternative to international supply chains that can often be costly, slow, and unreliable.

microbiology↗