Evaluation of an Instrumented Helmet for Measurement of Orthosis-Head Interface Forces in Pediatric Craniosynostosis

Postoperative cranial orthoses guide skull growth after endoscopy-assisted craniosynostosis surgery in infants, yet the forces they apply at the orthosis-head interface remain poorly characterized. Here, a cranial helmet with 12 soft magnetic tactile sensors is developed to measure these forces. The helmet, a computed tomography (CT)-derived replica of a patients first clinical helmet, is evaluated on patient-derived expandable head phantoms with and without a modeled craniotomy. The phantoms follow the first treatment phase of a female infant with unicoronal craniosynostosis, from surgery at 77 days to the end of the first helmet period at 160 days (843 mL), extended to 175 days (860 mL). As the phantom expands, contact develops progressively and remains non-uniform, with occipital and spheno-temporal regions as the dominant load-bearing sites. At 175 days, mean local forces reach 258.3 {+/-} 8.7 gf occipitally, 168.5 {+/-} 5.9 gf and 104.5 {+/-} 39.9 gf at two spheno-temporal sites, and 105.7 {+/-} 13.6 gf frontally. Repeated helmet fitting reproduces the sensor-level loading pattern. Compared with the phantom without the helmet, CT shows reduced peripheral displacement and redirection of expansion toward superior relief regions. The instrumented helmet described here provides a quantitative testbed for orthosis design and computational-model validation.

bioengineering↗

CT-Derived In Vitro Model Simulating Neonatal Cranial Growth

Purpose: This study presents an in vitro platform for quantitatively simulating cranial growth in neonates from 3 to 6 months of age. Methods: The system integrates a pneumatic-hydraulic actuation unit, multi-camera optical tracking, and a CT-compatible enclosure to replicate and measure intracranial expansion. A phantom head model was fabricated via 3D printing using cranial bones and flexible latex sutures, reproducing neonatal cranial biomechanics. Controlled hydraulic pressure simulates intracranial volume (ICV) growth, while surface and volumetric changes are captured through synchronized imaging. Results: Morphometric parameters - biparietal diameter, occipitofrontal diameter, cranial circumference, and ICV - were measured and compared against published reference data. The system achieved high reproducibility across repeated trials. CT-derived ICV values (R2 = 0.98) closely matched reference trends, with average manufacturing deviations of 0-4 mm between fabricated and reference geometries. Linear morphometric increments confirmed physiologically consistent expansion patterns. Conclusion: The proposed platform provides a quantitatively validated, controllable, and CT-compatible environment for studying neonatal cranial development. It enables biomechanical testing and device evaluation under ethical and repeatable in vitro conditions, with potential future applications in surgical training and pre-operative planning.

bioengineering↗