Search bioRxiv⌕ Search

Biology subjects

Cohen-Karni, T.

Publications and source records attributed to Cohen-Karni, T..

7 recordsLinked to original sources

Chronic Electrophysiology Captures Progressive Variability in DNA-Damaged Cardiac Networks

Electrophysiological recordings provide a key functional readout of cardiac health. Most in vitro studies rely on acute measurements rather than recording evolving functional changes. Here, we implement a microelectrode array (MEA) based system for chronic electrophysiological monitoring of human induced pluripotent stem cell-derived cardiomyocyte (iPSC-CM) monolayers. Electrophysiology recordings were maintained for up to 40 days, enabling longitudinal assessment of field potential amplitude, field potential duration, beat frequency, conduction velocity, and waveform morphology. Untreated iPSC-CM monolayers exhibited stable electrophysiological behavior throughout chronic culture. Following exposure to the cardiotoxic chemotherapeutic doxorubicin, chronic recordings captured progressive deterioration in electrical activity, including reduced field potential amplitude, altered repolarization dynamics, increased beat-to-beat variability, and reduced conduction that persisted after drug removal. Electrode-resolved analyses further revealed pronounced progressive spatial variability, highlighting localized responses that would be obscured by population-averaged measurements. Endpoint assays indicated reduced calcium transient amplitude and altered calcium reuptake, decreased mitochondrial membrane potential, and loss of connexin 43, findings consistent with the impaired electrical activity observed in chronic recordings. Together, these results establish chronic electrophysiological monitoring as a powerful approach for resolving the spatiotemporal progression of cardiotoxicity and other dynamic cardiac processes in vitro.

bioengineering↗

Predicting Macroscopic Axon Topology from Microscopic Kinematics: An Interactive Tracking and Random Walk Pipeline for Substrate-Dependent Cortical Neurospheres

The cortical neuron is a fundamental building block of the mammalian brain, and the morphology of its axonal projections is central to how functional circuits assemble. The trajectory along which an axon grows is a key determinant of connectivity, yet the kinematics of cortical axon outgrowth remain poorly quantified. Characterizing these dynamics is most tractable in vitro, where axonal growth can be measured directly and under controlled, reproducible conditions. Even in culture, however, this remains challenging because cortical neurons require dense plating for viability, and their soma is motile, so growth behavior is highly sensitive to local density and population context, complicating reproducible measurement of intrinsic dynamics. To overcome these limitations, we used size-controlled cortical neurospheres, which provide a fixed spatial origin and a reproducible environment, together with a custom semi-automated tracking pipeline to quantify single-axon kinematics across two functionalized substrates and two developmental phases. This approach revealed a substrate-dependent divergence in outgrowth: during the later developmental phase, axons on poly-D-lysine with laminin (PDL-LA) substrate grew faster than those on PDL, with a mean step size of 0.436 versus 0.339 {micro}m /min. Decomposing trajectories into Katz dynamic states, we built a generative biased random walk model that reproduces axonal behavior at both microscopic (single-axon) and macroscopic (network topology) scales. This open, reproducible framework links single-axon kinematics to network architecture, enabling the structural connectivity of neurospherebased circuits in vitro to be predicted from measurable growth dynamics, a necessary foundation for future studies linking circuit structure to emergent function.

bioengineering↗

Early electrical stimulation promotes functional recovery after volumetric muscle loss

Volumetric muscle loss (VML) injuries overwhelm the inherent regenerative capacity of skeletal muscle, causing persistent functional deficits with no routinely effective therapies. Electrical stimulation (ES) has been shown to preserve muscle structure in other injury models, but technical barriers have prevented daily delivery during the acute post-injury window when critical regenerative programs are established. Here, we developed a fully implantable bioelectronic system with nanoporous platinum-modified electrodes enabling daily therapeutic stimulation and electromyographic recording without repeated anesthesia in a rat tibialis anterior VML model. Animals receiving ES during the acute post-injury period (10 sessions over days 0-14) showed sustained functional improvement, reaching 90% of baseline torque at 8 weeks compared to 71% in unstimulated controls. This recovery reflected enhanced remodeling of injured muscle rather than synergistic muscle compensation. Histological analysis revealed coordinated early increases in vascularization, pro-regenerative macrophages, and satellite cells. These findings establish early ES as a promising intervention for promoting muscle regeneration after catastrophic injury.

bioengineering↗

Modular Assembly of Biohybrid Machines Using Force-Enhanced Skeletal Muscle Actuators

Muscle-based biohybrid systems integrate living muscle with engineered structures to create soft robots, biological models, and regenerative platforms. However, current actuators often lack strength and are difficult to assemble into complex devices. This study presents a suspended compliant skeleton that enhances muscle maturation by providing passive resistance, enabling high-stroke self-exercise without external stimulation. Using immortalized C2C12 cells, the resulting actuators achieved millimeter-scale strokes and millinewton-scale forces, surpassing previous benchmarks. Magnetic interfaces embedded in the skeleton allowed modular assembly into multi-degree-of-freedom devices such as grippers, arms, and positioning stages. These interfaces also support actuator replacement and repair, improving resilience and scalability. This approach significantly boosts engineered muscle performance and offers a robust, modular platform for building high-functioning, repairable biohybrid machines.

bioengineering↗

Wound state monitoring by multiplexed, electrochemical, real-time, localized, inflammation-tracking nitric oxide sensor (MERLIN)

Nitric oxide (NO) released endogenously by induced nitric oxide synthase (iNOS) in macrophages is a key regulatory biomarker for wound inflammation. Detecting NO directly on the wound bed is challenging due to its short half-life time (6 - 50 s), low physiological concentration (nM - {micro}M) and interferences in the complex wound environment. Existing NO sensors suffer from limitations such as rigid substrates, single point of detection and complex measurement setup. Here we present a compliant, multiplexed, electrochemical, real-time, localized, inflammation-tracking nitric oxide sensor (MERLIN) array for in vivo spatiotemporal measurement of NO, with high sensitivity (15.6 {+/-} 5.0 nA/M for 1.5 mm diameter electrodes), selectivity against nitrites (ca. 27900-fold), ascorbic acid (ca. 3800-fold), and uric acid (ca. 6900-fold), and low limit of detection (8.00 nM). We developed a robust device fabrication protocol, comprehensive and highly reproducible in vitro characterization yielding a consistent device performance deployed for wound healing diagnostics. MERLIN spatiotemporally tracked NO on rat skin wounds for 7 days and results indicated that NO peaks on day 3, in line with previously reported iNOS activity. MERLIN allows spatial mapping of the NO gradient across the wound bed, which can be used to provide diagnostic information to assist wound care.

bioengineering↗

Electrocatalytic on-site oxygenation for transplanted cell-based-therapies

Implantable cell therapies and tissue transplants require sufficient oxygen supply to function and are limited by a delay or lack of vascularization from the transplant host1, 2. Exogenous oxygen production can support cells and tissues, such as pancreatic islets and engineered therapeutic cells. Previous oxygenation strategies have targeted gas circulation or decomposition of solid peroxides. These strategies however require bulky implants, transcutaneous supply lines, and are limited in their total oxygen production or regulation3, 4. Readily integrated and controlled production of oxygen has eluded cell therapy devices. Here, we show an electrocatalytic approach that enables bioelectronic control of oxygen generation in complex cellular environments to sustain engineered cell viability and therapy production under hypoxic stress and at high cell densities. Nanostructured sputtered iridium oxide serves as an ideal catalyst for oxygen evolution reaction (OER) at neutral pH. It enables a lower OER onset and shows selective oxygen production without evolution of toxic side products over a 300 mV window of operation. This electrocatalytic on site oxygenator (ecO2) can sustain high cell loadings (>60k cells/mm3) in hypoxic conditions in vitro and in vivo. Our results demonstrate that exogenous oxygen production devices can be readily integrated into bioelectronic platforms and enable high cell loadings in smaller device footprints with broad applicability.

bioengineering↗

Bioelectrical Interfaces with Cortical Spheroids in Three-Dimensions

Three-dimensional (3D) neuronal spheroid culture serves as a powerful model system for the investigation of neurological disorders and drug discovery. The success of such a model system requires techniques that enable high-resolution functional readout across the entire spheroid. Conventional microelectrode arrays and implantable neural probes cannot monitor the electrophysiology activity across the entire native 3D geometry of the cellular construct. Here, we demonstrate a 3D self-rolled biosensor array (3D-SR-BA) integrated with a 3D cortical spheroid culture for simultaneous in-vitro electrophysiology recording, functional Ca2+ imaging, and drug effect monitoring. We have also developed a signal processing pipeline to detect neural firings with high spatiotemporal resolution from the electrophysiology recordings based on established spike sorting methods. The 3D-SR-BAs cortical spheroid interface provides a stable, high sensitivity recording of neural action potentials (< 50 V peak-to-peak amplitude). The 3D-SR-BA is demonstrated as a potential drug screening platform through the investigation of the neural response to the excitatory neurotransmitter glutamate. Upon addition of glutamate, the neuronal firing rates increased notably corresponding well with the functional Ca2+ imaging. Our entire system, including the 3D-SR-BA integrated with neural spheroid culture, enables simultaneous electrophysiology recording and functional Ca2+ imaging with high spatiotemporal resolution in conjunction with chemical stimulation. We demonstrate a powerful toolset for future studies of tissue development, disease progression, and drug testing and screening, especially when combined with native spheroid cultures directly extracted from humans.

bioengineering↗