Search bioRxiv⌕ Search

Biology subjects

Clerx, M.

Publications and source records attributed to Clerx, M..

14 recordsLinked to original sources

Comparison of in silico predictions of action potential duration in response to inhibition of IKr and ICaL with new human ex vivo recordings

During drug development, candidate compounds are extensively tested for proar-rhythmic risk and in particular risk of Torsade de Pointes (TdP), as indicated by prolongation of the QT interval. Drugs that inhibit the rapid delayed rectifier K+ current (IKr) can prolong the action potential duration (APD) and thereby the QT interval, and so are routinely rejected. However, simultaneous inhibition of the L-type Ca2+ current (ICaL) can mitigate the effect of IKrinhibition, so that including both effects can improve test specificity. Mathematical models of the action potential (AP) can be used to predict the APD prolongation resulting from a given level of IKr and ICaL inhibition, but for use in safety-testing their predictive capabilities should first be carefully verified. We present the first systematic comparison between experimental drug-induced APD and predictions by AP models. New experimental data were obtained ex vivo for APD response to IKr and/or ICaL inhibition by applying 9 compounds at different concentrations to adult human ventricular trabeculae at physiological temperature. Compounds with similar effects on IKr and ICaL exhibited less APD prolongation compared to selective IKr inhibitors. We then integrated in vitro IC50 patch-clamp data for IKr and ICaL inhibition by the tested compounds into simulations with AP models. Models were assessed against the ex vivo data on their ability to recapitulate drug-induced APD changes observed experimentally. None of the tested AP models reproduced the APD changes observed experimentally across all combinations and degrees of IKr and/or ICaL inhibition: they matched the data either for selective IKr inhibitors or for compounds with comparable effects on IKr and ICaL. This work introduces a new benchmarking framework to assess the predictivity of current and future AP models for APD response to IKr and/or ICaL inhibition. This is an essential primary step towards an in silico framework that integrates in vitro data for translational clinical cardiac safety. Author summaryBefore an investigational drug reaches patients, it is tested in vitro to ensure it does not disrupt the hearts electric activity. This testing often focuses on the drugs ability to block a specific current called IKr, which, if inhibited, can prolong the heart cells action potential duration (APD), which is associated with an increased risk of irregular heartbeats (proarrhythmia). Our study examines how blocking another current, ICaL, along with IKr, affects APD. We found that adding ICaL inhibition may mitigate the proarrhythmic effects caused by IKr inhibition alone. Understanding this balance can improve how we assess the cardiac safety of new drugs, potentially saving promising compounds from being incorrectly discarded. Currently, mathematical models help predict such cardiac responses, but no existing model accurately predicted our findings. Our new data could aid in developing more predictive models in the future. This will contribute to safer drug development and more effective treatments.

pharmacology and toxicology↗

Resolving artefacts in voltage-clamp experiments with computational modelling: an application to fast sodium current recordings

Cellular electrophysiology is the foundation of many fields, from basic science in neurology, cardiology, oncology to safety critical applications for drug safety testing, clinical phenotyping, etc. Patch-clamp voltage clamp is the gold standard technique for studying cellular electrophysiology. Yet, the quality of these experiments is not always transparent, which may lead to erroneous conclusions for studies and applications. Here, we have developed a new computational approach that allows us to explain and predict the experimental artefacts in voltage-clamp experiments. The computational model captures the experimental procedure and its inadequacies, including: voltage offset, series resistance, membrane capacitance and (imperfect) amplifier compensations, such as series resistance compensation and supercharging. The computational model was validated through a series of electrical model cell experiments. Using this computational approach, the artefacts in voltage-clamp experiments of cardiac fast sodium current, one of the most challenging currents to voltage clamp, were able to be resolved and explained through coupling the observed current and the simulated membrane voltage, including some typically observed shifts and delays in the recorded currents. We further demonstrated that the typical way of averaging data for current-voltage relationships would lead to biases in the peak current and shifts in the peak voltage, and such biases can be in the same order of magnitude as those differences reported for disease-causing mutations. Therefore, the presented new computational pipeline will provide a new standard of assessing the voltage-clamp experiments and interpreting the experimental data, which may be able to rectify and provide a better understanding of ion channel mutations and other related applications.

systems biology↗

Variability in reported midpoints of (in)activationof cardiac INa

Electrically active cells like cardiomyocytes show variability in their size, shape, and electrical activity. But should we expect variability in the properties of their ionic currents? In this brief review we gather and visualise measurements of two important electrophysiological parameters: the midpoints of activation and inactivation of the cardiac fast sodium current, INa. We find a considerable variation in reported mean values between experiments, with a smaller cell-to-cell variation within experiments. We show how the between-experiment variability can be decomposed into a correlated and an uncorrelated component, and that the correlated component is much larger and affects both midpoints almost equally. We then review biological and methodological issues that might explain the observed variability, and attempt to classify each as within-experiment or correlated and uncorrelated between-experiment factors. Although the existence of some variability in measurements of ionic currents is well-known, we believe that this is the first work to systematically review it and that the scale of the observed variability is much larger than commonly appreciated, which has implications for modelling and experimental design.

cell biology↗

Optimal experimental designs for characterising ion channel gating by filling the phase-voltage space of model dynamics

Voltage-clamp waveforms are imposed in the patch-clamp electrophysiology technique to provoke ion currents, the particular waveform that is used is known as the voltage-clamp protocol. Designing protocols to probe and quantify how gating for a particular ion channel occurs has typically been done manually and results in a suite of long protocols. It is desirable to gain the same, or even more, information in a shorter time, and also to automate the process of designing these protocols. In this paper we introduce a new optimal experimental design objective for ion channel characterisation, which involves considering a 3-dimensional phase space for the channel states combined with the voltage, using room-temperature hERG/Kv11.1 currents as an example. A range of designs are proposed, the best of which visits 82% of the discretised phase-voltage space in a 9 second protocol. This new protocol design strategy results in a simulated current visiting a wide range of channel gating states, at a wide variety of voltages, and we therefore expect these designs to be very useful in characterising ion currents, parameterising models, as well as being a challenging test of assumptions made about ion channel gating.

biophysics↗

Model-driven optimal experimental design for calibrating cardiac electrophysiology models

Models of the cardiomyocyte action potential (AP) have contributed immensely to the understanding of heart function, pathophysiology, and the origin of heart rhythm disturbances. However, AP models are nonlinear, complex, and can contain more than a hundred differential equations, making them difficult to parameterise. Therefore, cellular cardiac models have been limited to describing average cell dynamics, when cell-specific models would be ideal to uncover inter-cell variability but are too experimentally challenging to be achieved. Here, we focus on automatically designing experimental protocols that allow us to better identify cell-specific maximum conductance values for each major current type--optimal experimental designs--for both voltage-clamp and current-clamp experiments. We show that optimal designs are able to perform better than many of the existing experiment designs in the literature in terms of identifying model parameters and hence model predictive power. For cardiac cellular electrophysiology, this approach will allow researchers to define their hypothesis of the dynamics of the system and automatically design experimental protocols that will result in theoretically optimal designs.

systems biology↗

Leak current, even with gigaohm seals, can cause misinterpretation of stem-cell derived cardiomyocyte action potential recordings

Human induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs) have become an essential tool to study arrhythmia mechanisms. Much of the foundational work on these cells, and the computational models built from the resultant data, has overlooked the contribution of seal-leak current on the immature and heterogeneous phenotype that has come to define these cells. Here, we use in silico and in vitro studies to demonstrate how seal-leak current depolarises action potentials (APs), substantially affecting their morphology, even with seal resistances (Rseal) above 1 G{Omega}. We show that compensation of this leak current is difficult due to challenges with recording accurate measures of Rseal during an experiment. Using simulation, we show that Rseal measures: 1) change during an experiment, invalidating the use of pre-rupture values, and 2) are polluted by the presence of transmembrane currents at every voltage. Finally, we posit the background sodium current in baseline iPSC-CM models imitates the effects of seal-leak current and is increased to a level that masks the effects of seal-leak current on iPSC-CMs. Based on these findings, we make three recommendations to improve iPSC-CM AP data acquisition, interpretation, and model-building. Taking these recommendations into account will improve our understanding of iPSC-CM physiology and the descriptive ability of models built from such data. Key pointsO_LIHuman induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs) are an essential tool in the study of cardiac arrhythmia mechanisms. C_LIO_LITheir immature and heterogeneous action potential phenotype complicates the interpretation of experimental data, and has slowed their acceptance in industry and academia. C_LIO_LIWe suggest that a leak current caused by an imperfect pipette-membrane seal during single-cell patch-clamp experiments is partly responsible for inducing this phenotype. C_LIO_LIUsing in vitro experiments and computational modelling, we show that this seal-leak current affects iPSC-CM AP morphology, even under ideal experimental conditions. C_LIO_LIBased on these findings, we make recommendations that should be considered when interpreting, analysing and fitting iPSC-CM data. C_LI

physiology↗

Treatment response prediction: Is model selection unreliable?

Quantitative modelling has become an essential part of the drug development pipeline. In particular, pharmacokinetic and pharmacodynamic models are used to predict treatment responses in order to optimise clinical trials and assess the safety and efficacy of dosing regimens across patients. It is therefore crucial that treatment response predictions are reliable. However, the data available to fit models are often limited, which can leave considerable uncertainty about the best model to use. Common practice is to select the model that is most consistent with the observed data based on the Akaike information criterion (AIC). Another popular approach is to average the predictions across the subset of models consistent with the data. In this article, we argue that both approaches can lead to unreliable predictions, as treatment responses typically display nonlinear dynamics, so models can be consistent with the observed dynamics, whilst predicting incorrect treatment responses. This is especially the case when predicting treatment responses for either times or dosing regimens that go beyond the observed dynamics. Across a range of experiments on both real laboratory data and synthetically derived data on Neisseria gonorrhoeae response to ciprofloxacin, we show that probabilistic averaging of models results in more reliable treatment response predictions.

systems biology↗

Models of the cardiac L-type calcium current: a quantitative comparison

The L-type calcium current (ICaL) plays a critical role in cardiac electrophysiology, and models of ICaL are vital tools to predict arrhythmogenicity of drugs and mutations. Five decades of measuring and modelling ICaL have resulted in several competing theories (encoded in mathematical equations). However, the introduction of new models has not typically been accompanied by a data-driven critical comparison with previous work, so that it is unclear which model is best suited for any particular application. In this review, we describe and compare 73 published mammalian ICaL models, and use simulated experiments to show that there is a large variability in their predictions, which is not substantially diminished when grouping by species or other categories. We provide model code for 60 models, list major data sources, and discuss experimental and modelling work that will be required to reduce this huge list of competing theories and ultimately develop a community consensus model of ICaL.

cell biology↗

Accounting for variability in ion current recordings using a mathematical model of artefacts in voltage-clamp experiments

Mathematical models of ion channels, which constitute indispensable components of action potential models, are commonly constructed by fitting to whole-cell patch-clamp data. In a previous study we fitted cell-specific models to hERG1a (Kv11.1) recordings simultaneously measured using an automated high-throughput system, and studied cell-cell variability by inspecting the resulting model parameters. However, the origin of the observed variability was not identified. Here we study the source of variability by constructing a model that describes not just ion current dynamics, but the entire voltage-clamp experiment. The experimental artefact components of the model include: series resistance, membrane and pipette capacitance, voltage offsets, imperfect compensations made by the amplifier for these phenomena, and leak current. In this model, variability in the observations can be explained by either cell properties, measurement artefacts, or both. Remarkably, by assuming that variability arises exclusively from measurement artefacts, it is possible to explain a larger amount of the observed variability than when assuming cell-specific ion current kinetics. This assumption also leads to a smaller number of model parameters. This result suggests that most of the observed variability in patch-clamp data measured under the same conditions is caused by experimental artefacts, and hence can be compensated for in post-processing by using our model for the patch-clamp experiment. This study has implications for the question of the extent to which cell-cell variability in ion channel kinetics exists, and opens up routes for better correction of artefacts in patch-clamp data.

biophysics↗

Rapid characterisation of hERG channel kinetics II: temperature dependence

Ion channel behaviour can depend strongly on temperature, with faster kinetics at physiological temperatures leading to considerable changes in currents relative to room temperature. These temperature-dependent changes in voltage-dependent ion channel kinetics (rates of opening, closing and inactivating) are commonly represented with Q10 coefficients or an Eyring relationship. In this paper we assess the validity of these representations by characterising channel kinetics at multiple temperatures. We focus on the hERG channel, which is important in drug safety assessment and commonly screened at room temperature, so that results require extrapolation to physiological temperature. In Part I of this study we established a reliable method for high-throughput characterisation of hERG1a (Kv11.1) kinetics, using a 15 second information-rich optimised protocol. In this Part II, we use this protocol to study the temperature dependence of hERG kinetics using CHO cells over-expressing hERG1a on the Nanion SyncroPatch 384PE, a 384-well automated patch clamp platform, with temperature control. We characterise the temperature dependence of hERG gating by fitting the parameters of a mathematical model of hERG kinetics to data obtained at five distinct temperatures between 25 and 37 {degrees}C, and validate the models using different protocols. Our models reveal that activation is far more temperature sensitive than inactivation, and we observe that the temperature dependency of the kinetic parameters is not represented well by Q10 coefficients: it broadly follows a generalised, but not the standardly-used, Eyring relationship. We also demonstrate that experimental estimations of Q10 coefficients are protocol-dependent. Our results show that a direct fit using our 15 second protocol best represents hERG kinetics at any given temperature, and suggests that predictions from the Generalised Eyring theory may be preferentially used if no experimentally-derived data are available.\n\nStatement of SignificanceIon channel currents are highly sensitive to temperature changes. Yet because many experiments are performed more easily at room temperature, it is common to extrapolate findings to physiological temperatures through the use of Q10 coefficients or Eyring rate theory. By applying short, information-rich protocols that we developed in Part I of this study we identify how kinetic parameters change over temperature. We find that the commonly-used Q10 and Eyring formulations are incapable of describing the parameters temperature dependence, a more Generalised Eyring relationship works well, but remeasuring kinetics and refitting a model is optimal. The findings have implications for the accuracy of the many applications of Q10 coefficients in electrophysiology, and suggest that care is needed to avoid misleading extrapolations in their many scientific and industrial pharmaceutical applications.

biophysics↗

Rapid characterisation of hERG channel kinetics I: using an automated high-throughput system

Predicting how pharmaceuticals may affect heart rhythm is a crucial step in drug-development, and requires a deep understanding of a compounds action on ion channels. In vitro hERG-channel current recordings are an important step in evaluating the pro-arrhythmic potential of small molecules, and are now routinely performed using automated high-throughput patch clamp platforms. These machines can execute traditional voltage clamp protocols aimed at specific gating processes, but the array of protocols needed to fully characterise a current is typically too long to be applied in a single cell. Shorter high-information protocols have recently been introduced which have this capability, but they are not typically compatible with high-throughput platforms. We present a new high-information 15 s protocol to characterise hERG (Kv11.1) kinetics, suitable for both manual and high-throughput systems. We demonstrate its use on the Nanion SyncroPatch 384PE, a 384 well automated patch clamp platform, by applying it to CHO cells stably expressing hERG1a. From these recordings we construct 124 cell-specific variants/parameterisations of a hERG model at 25 {degrees}C. A further 8 independent protocols are run in each cell, and are used to validate the model predictions. We then combine the experimental recordings using a hierarchical Bayesian model, which we use to quantify the uncertainty in the model parameters, and their variability from cell to cell, which we use to suggest reasons for the variability. This study demonstrates a robust method to measure and quantify uncertainty, and shows that it is possible and practical to use high-throughput systems to capture full hERG channel kinetics quantitatively and rapidly.\n\nStatement of SignificanceWe present a method for high-throughput characterisation of hERG potassium channel kinetics, via fitting a mathematical model to results of over one hundred single cell patch clamp measurements collected simultaneously on an automated voltage clamp platform. The automated patch clamp data are used to parameterise a mathematical ion channel model fully, opening a new era of automated and rapid development of mathematical models from quick and cheap experiments. The method also allows ample data for independent validation of the models and enables us to study experimental variability and propose its origins. In future the method can be applied to characterise changes to hERG currents in different conditions, for instance at different temperatures (see Part II of the study) or under mutations or the action of pharmaceuticals; and should be easily adapted to study many other currents.

biophysics↗

Four ways to fit an ion channel model

Computational models of the cardiac action potential are increasingly being used to investigate the effects of genetic mutations, predict pro-arrhythmic risk in drug development, and to guide clinical interventions. These safety-critical applications, and indeed our understanding of the cardiac action potential, depend on accurate characterisation of the underlying ionic currents. Four different methods can be found in the literature to fit ionic current models to single-cell measurements: (Method 1) fitting model equations directly to time constant, steady-state, and I-V summary curves; (Method 2) fitting by comparing simulated versions of these summary curves to their experimental counterparts; (Method 3) fitting to the current traces themselves from a range of protocols; and (Method 4) fitting to a single current trace from an information-rich voltage clamp protocol. We compare these methods using a set of experiments in which hERG1a current from single Chinese Hamster Ovary (CHO) cells was characterised using multiple fitting protocols and an independent validation protocol. We show that Methods 3 and 4 provide the best predictions on the independent validation set, and that the short information-rich protocols of Method 4 can replace much longer conventional protocols without loss of predictive ability. While data for Method 2 is most readily available from the literature, we find it performs poorly compared to Methods 3 and 4 both in accuracy of predictions and computational efficiency. Our results demonstrate how novel experimental and computational approaches can improve the quality of model predictions in safety-critical applications.\n\nStatement of SignificanceMathematical models have been constructed to capture and share our understanding of the kinetics of ion channel currents for almost 70 years, and hundreds of models have been developed, using a variety of techniques. We compare how well four of the main methods fit data, how reliable and efficient the process of fitting is, and how predictive the resulting models are for physiological situations. The most widely-used traditional approaches based on current-voltage and time constant-voltage curves do not produce the most predictive models. Short, optimised experimental voltage clamp protocols can be used to create models that are as predictive as ones derived from traditional protocols, opening up possibilities for measuring ion channel kinetics faster, more accurately and in single cells. As these models often form part of larger multi-scale action potential and tissue electrophysiology models, improved ion channel kinetics models could influence the findings of thousands of simulation studies.

biophysics↗

Reproducible model development in the Cardiac Electrophysiology Web Lab

The modelling of the electrophysiology of cardiac cells is one of the most mature areas of systems biology. This extended concentration of research effort brings with it new challenges, foremost among which is that of choosing which of these models is most suitable for addressing a particular scientific question. In a previous paper, we presented our initial work in developing an online resource for the characterisation and comparison of electrophysiological cell models in a wide range of experimental scenarios. In that work, we described how we had developed a novel protocol language that allowed us to separate the details of the mathematical model (the majority of cardiac cell models take the form of ordinary differential equations) from the experimental protocol being simulated. We developed a fully-open online repository (which we termed the Cardiac Electrophysiology Web Lab) which allows users to store and compare the results of applying the same experimental protocol to competing models. In the current paper we describe the most recent and planned extensions of this work, focused on supporting the process of model building from experimental data. We outline the necessary work to develop a machine-readable language to describe the process of inferring parameters from wet lab datasets, and illustrate our approach through a detailed example of fitting a model of the hERG channel using experimental data. We conclude by discussing the future challenges in making further progress in this domain towards our goal of facilitating a fully reproducible approach to the development of cardiac cell models.

systems biology↗